www.factorelectronics.com
V-66 INSTALLATION INSTRUCTIONS RS-232 CONTROL
INSTALLATION:
V-66 RS-232 Serial Port Control
The V-66 RS-232 Serial commands continued.
(00:disconnect
01:connected)
Inquiry command structure
(2) ?xxPP'CR'
xx: stands for control object code
10 : All Zone of Main unit 1.
20 : All Zone of Main unit 2.
30 : All Zone of Main unit 3.
11 : Zone1 of Main unit 1
12 : Zone2 of Main unit 1
13 : Zone3 of Main unit 1
14 : Zone4 of Main unit 1
15 : Zone5 of Main unit 1
16 : Zone6 of Main unit 1
PP: Stands for control action code.
PA: PA
control
PR: Power
control
MU: Mute
control
DT: DT
control
VO: Volume
control
TR: Treble
control
BS: Bass
control
BL: Balance
control
CH: Source
control
LS: keypad connecting status
Reply command
: >xxPPuu'CR'
Reply command
: >xxPPuu'CR'
;********needs to be 8 ASCII codes.
Key in
1<********'CR' change
Source 1
Name display
Key in
2<********'CR' change
Source 2
Name display
Key in
3<********'CR' change
Source 3
Name display
Key in
4<********'CR' change
Source 4
Name display
Key in
5<********'CR' change
Source 5
Name display
Key in
6<********'CR' change
Source 6
Name display
Key in
M<********'CR' change the name in the display
On the keypad when the keypad is turned on.
Key in
<9600'CR' change RS232 speed rate to 9600
Key in
<19200'CR' change RS232 speed rate to 19200
Key in
<38400'CR' change RS232 speed rate to
38400
Key in
<57600'CR' change RS232 speed rate to
57600
Key in
<115200'CR' change RS232 speed rate to
115200
Key in
<230400'CR' change RS232 speed rate to
230400
When unplugging and re-plugging the AC power cord, the
Baud speed rate will return to 9600.
(
Baud Rate 9600, 8, N, 1 , DB9 Connector Pin out, Tx, Rx, GND)