Suitable records 

184. The record of each thorough examination and test of RPE carried out should include: 

 

the name and address of the employer responsible for the RPE; 

 

particulars  of  the  equipment  and  of  the  distinguishing  number  or  mark,  together  with  a  description 

sufficient to identify it, and the name of the maker; 

 

the date of examination and the name and signature or other acceptable means of identifying the person 

carrying out the examination and test; 

 

the condition of the equipment and details of any defect found, including for canister or filter respirators, 

the state of the canister and the condition of the filter; 

 

for  self-contained  compressed  air/gas  breathing  apparatus,  the  pressure  of  air/gas  in  the  supply 

cylinder; and 

 

for powered/power-assisted respirators and breathing apparatus, the volume flow rate to ensure that 

they can deliver at least the manufacturer's minimum recommended flow rate. 
 

Keeping records 

185. Employers may keep records in any format, eg on paper or electronically. Records should be kept readily 
accessible and retrievable at any reasonable time for examination by safety representatives or inspectors etc. 

 

Accommodation for, and checking of, PPE 

186. Employers should ensure that accommodation is provided for PPE so that it can be safely stored or kept 
when it is not in use. The adequacy of the accommodation will vary according to the quantity, type and its use, 
eg pegs, (labelled) lockers, shelves or containers etc. The storage should be adequate to protect the PPE from 
contamination, loss or damage by, for example, harmful substances, damp or sunlight. Where quantities of PPE 
are stored, equipment which is ready for use should be clearly segregated from that which is awaiting repair or 
maintenance.  Where  PPE  becomes  contaminated  during  use,  and  especially  by  biological  agents,  the 
accommodation  should  be  separate  from  any  the  employer  provides  for  ordinary  clothing  and  equipment. 
Employers may also have duties under the Workplace (Health, Safety and Welfare) Regulations 1992 to provide 
accommodation for PPE.14. 

 

187. All PPE should be checked regularly to ensure that it continues to function and provide protection. The 
types of checks should be suited to that item of PPE and be able to detect significant deterioration. The more 
likely the performance of a particular item of PPE is to deteriorate, the more often it needs checking. Whoever 
does this work should be sufficiently knowledgeable and trained to identify deterioration and significant 
faults. Equipment that has deteriorated significantly or is faulty should be effectively repaired or disposed of 
safely.

 

Reproduced from COSHH Approved Codes of Practice L5 by Factair Ltd with the permission of the Controller of 
HMSO. 
Contains public sector information licensed under the Open Government Licence v3.0

 

 
 

Содержание F6001

Страница 1: ...0 F6001 SAFE AIR TESTER OPERATING MANUAL FAC QAM 096 Issue D 03 21...

Страница 2: ...12 Appendix 2 Using the test port for other Draeger tubes 14 Appendix 3 Reading and disposal of Draeger Tubes and Oil Impactor 16 Appendix 4 Helpful Tips 21 Appendix 5 Air Quality Testing Why 23 Inter...

Страница 3: ...mpactors are supplied in packs of 10 and show the degree of oil contamination on a screen Calibration and Warranty Safe Air Testers leave our factory with a 12 month warranty and calibration certifica...

Страница 4: ...Draeger Impactor and tube test port Air Inlet F3002 HP Regulator optional extra Storage for manual and F3002 HP regulator hose Mains power adaptor TUB0053 8103560 Draeger Oil Impactors optional extra...

Страница 5: ...with this instrument Batteries must be installed prior to use unless it is the intention to power the unit solely from a mains supply To install the batteries lift the tester out of its case open the...

Страница 6: ...rial number and a tick or cross symbol will indicate whether it is within the recommended calibration period Press the arrow key to progress to the main menu The main menu has 3 options available from...

Страница 7: ...ration will operate for an extended period to stabilise the Oxygen cell You now have the option of entering a description for the test location if you wish to use numbers press the function button Pus...

Страница 8: ...hat the flow control valve is fully closed and then connect the F3002 high pressure regulator assembly to the cylinder or charging hose to be tested ensuring that the regulator has the correct type of...

Страница 9: ...ll be passed through the test port and across the electronic cells This clears contaminants from previous tests and ensures that a representative sample is being tested Once the purge has finished the...

Страница 10: ...fail against the standard displayed in the top right corner of the screen For water content on high pressure tests both the measured value in mg m3 and the atmospheric dewpoint are provided If the te...

Страница 11: ...n press the right hand arrow To delete a test highlight it then press the trash can button All tests can be deleted by selected the multiple trash can icon Note Once the instrument has saved 20 result...

Страница 12: ...Tester Results F4000 F6000 series software Then click on the File drop down menu and select import test results from F6000 via USB connection You will then be able to choose the location where you wou...

Страница 13: ...st due Test engineer and relevant address Note These details can be saved as default When complete you can save the test result file and if required print off a certificate In the UK Health and Safety...

Страница 14: ...e and time are set prior to the unit being supplied but they can be adjusted as necessary To select the units of measure and test standard press the right hand icon In this menu you can then choose da...

Страница 15: ...new test and after the unit had calibrated the oxygen cell and you have input the test location details you will have the option to select a tube test as shown press the button to proceed In this sub...

Страница 16: ...corner to proceed The test will proceed as described in section 3 and at the end of it you will be prompted to enter the result from the tube For the Nitrous fumes and Sulphur dioxide tubes enter the...

Страница 17: ...ickly identify minute quantities of oil For tests that pass with an oil concentration of less than 0 05mg m3 the screen will remain blank For tests above that read as follows The bottom line represent...

Страница 18: ...Using the Tube Tip Cutter place the ampoule section in the platform at the bottom Note Make sure the tube is against the back wall of the cutter Line up the black dot nearest the end of the tube with...

Страница 19: ...a slight discoloration Failed test Mineral oil The white crystals will show a light brown or darker discoloration Synthetic oil The white crystals will show a yellow discoloration Note best seen by c...

Страница 20: ...nvestigation will be required to determine the source of the contamination Disposal of Draeger Tubes When Draeger tubes have been used or unopened tubes have exceeded their expiry date they should be...

Страница 21: ...hand pump Break any ampoules where applicable Dispose of the tubes as stated in Methods 1 2 or 3 NOTE As an alternative a local authority approved waste disposal contractor can be employed to collect...

Страница 22: ...ic dewpoint The final test result for moisture will therefore display the limit for the sensor Make sure the system flow control valve is closed after each test Connecting an air supply to the Tester...

Страница 23: ...tor tube with the arrows facing outwards Never break the glass ampoule in the oil tube before the test Only use the detector tubes that the Tester is calibrated for Once used be aware that the tube ti...

Страница 24: ...t in air entering the filtration at too high a temperature this will cause the filtration to prematurely fail and pass excess levels of oil and water Malfunctioning dryers can disturb the oxygen conce...

Страница 25: ...onditions of usage and storage of any compressed air supply is not known the pressure dewpoint shall not exceed 11 C Dewpoint 50 F 67 PPM v v for SCBA use in extreme cold a dew point not to exceed 65...

Страница 26: ...ty is tested whenever it is first moved into a new position or prevailing wind conditions change The final decision on frequency of test is the responsibility of the Employer and needs to not only ref...

Страница 27: ...e condition of the equipment and details of any defect found including for canister or filter respirators the state of the canister and the condition of the filter for self contained compressed air ga...

Страница 28: ...quality of the air supplied Table A 2 provides a summary of the main elements associated with a compressor system for producing breathable air In addition to the careful and installation of the system...

Страница 29: ...quency of use When the air supply is from mobile compressors the employer should ensure that wherever a compressor is located the quality of air it supplies is not compromised by nearby contaminants I...

Страница 30: ...is not in use The adequacy of the accommodation will vary according to the quantity type and its use eg pegs labelled lockers shelves or containers etc The storage should be adequate to protect the PP...

Страница 31: ...compatible with the BA Never place the hose inlet near to potential sources of contamination eg vehicle exhausts Never use the equipment without the waist belt Never use a light duty airline hose whe...

Страница 32: ...to as low a level as possible and shall be far below the national exposure limit Combination effects of more than one contaminant shall be taken into account 1999 Respiratory protective equipment at...

Страница 33: ...32 Factair Ltd 49 Boss Hall Road Ipswich Suffolk IP1 5BN UK Tel Sales 44 0 1473 746400 Tel Hire 44 0 1473 746444 Fax 44 0 1473 747123 Email enquiries factair co uk www factair co uk...

Отзывы: