Preventing surges 

Keep values ​​in the line supply voltage in the Table "Technical specifications". In normal operation, the automatic 
alignment circuit voltage ensures the maintenance of tension in the acceptable range. The supply voltage higher than 
the permissible value can damage the welding machine. Operators should be fully aware of this risk and be able to 
take appropriate steps.

If a standard load is exceeded, the welder can enter a protective mode and suddenly stop working. This means that 
the standard load is exceeded, the heat has launched a thermal switch, which caused the machine to stop. Lamp 
lights up on the operating panel welding machine. In such a situation, do not remove the power plug to allow the fan to 
cool the welding machine. Exclusion of the lamp indicates the temperature drop to a normal level. You can take further 
work.

ATTENTION ! 

When welding components which form an integral part of the vehicle it is essential to disconnect the battery or use 
special protection. Otherwise, the electronic parts of the vehicle can be permanently damaged. When welding to 
connect the handle mass close as possible to the weld site.

D. MAINTENANCE 

D. MAINTENANCE 

Regularly remove dust with clean compressed air. If the unit is in working conditions in the smoke, in the heavily 
polluted air every day remove accumulated dust.

Air pressure should be maintained at a level not to damage the small components inside the machine max. 2-4 bar.

Inspect the internal welder circuits, check the accuracy and reliability of connections (in particular equipment and 
parts). In the case of notice of rust and loosening of the connection remove rust and oxide coating with abrasive 
paper, and re-connect securely. Avoid situations where water or steam could get into the device. In the case of 
welding moisture should dry it, and then check the insulation of the device (also between calls and contacts). After 
checking that everything is in order, you can continue working.

Содержание KRAMER MIG/MMA 185

Страница 1: ...ORIGINAL INSTRUCTIONS 2018 MANUAL WELDING...

Страница 2: ...KING 7 B INSTALLING SPOOL WITH welding wire 9 C INSTALLATION shielding gas bottle 10 6 WELDING PROCESS MIG MAG 12 7 CURRENT OPERATING UNIT 13 A WORKING CONDITIONS 13 B SAFETY 13 C PRECAUTIONS 13 D MAI...

Страница 3: ...h long sleeves Static electricity can damage electronic components Use approved face shields and welding shields Always use protective clothing designed for welders Metal splinters can injure your eye...

Страница 4: ...fety and fire Welded components could burn Wire protruding from the burner is sharp and can cause skin puncture Risk of fire and explosion During welding work may lead to a fire Welding station must b...

Страница 5: ...ntial difficulties in ensuring electromagnetic compatibility in those locations due to conducted and radiated disturbances The device should be used in accordance with the Regulation of the Minister o...

Страница 6: ...s equipped with functions option electrode welding MMA and additionally has the ability to self shielded welding wire FCAW Flux 4 TECHNICAL DATA 4 TECHNICAL DATA Table 1 Technical data Parameter KRAME...

Страница 7: ...perating instructions in j Polish 5 OPERATION 5 OPERATION AND BEFORE WORK AND BEFORE WORK Before starting work you must specify the place where the device is to be operated Check voltage value phase a...

Страница 8: ...ront description KRAMER MIG MAG 185 Figure 1 Front panel Warning LED thermal protection Socket positive polarity Adjusting dial wire feed speed Intensity control knob of welding current and voltage Mo...

Страница 9: ...ase the pressure feed rollers End of the wire inserted into the guide at the back of the tray and carry it over the driving roller introducing nozzle of the welding gun Push the wire in the groove dri...

Страница 10: ...ion of the reel of welding wire C INSTALLATION shielding gas bottle Connect with semiautomatic bottle with a suitable cable Unscrew the regulator valve prior to welding After completion of welding the...

Страница 11: ...3 Page 11 with 23 Page 11 with 23 Page 11 with 23 MANUAL KRAMER Technik MIG MMA 185 Figure 3 Back of the device Figure 3 Back of the device warning sign nameplate Fan Switch ON OFF Power cord Gas conn...

Страница 12: ...2 ABOUT Primary shielding gases for welding MIG inert gases such as argon helium and active gases in the MAG CO 2 H 2 ABOUT Primary shielding gases for welding MIG inert gases such as argon helium and...

Страница 13: ...TY Actually the installed device with overvoltage protection overcurrent protection and overtemperature switches off automatically under the conditions beyond the defined as the standard However long...

Страница 14: ...take further work ATTENTION When welding components which form an integral part of the vehicle it is essential to disconnect the battery or use special protection Otherwise the electronic parts of the...

Страница 15: ...roken blocked Check that the end of the current contribution and the guide wire is selected according to the diameter and type of welding wire The device has stopped welding lit the lamp thermal prote...

Страница 16: ...ntally friendly manner As the owner of the equipment should obtain information on approved collection systems from our local representative By following these guidelines protect environment and human...

Страница 17: ...tek shall not be liable for any errors or omissions We reserve the right to change the specifications of the products described at any time without prior notice ATTENTION The content of this manual h...

Страница 18: ...4 EN 55011 2009 A1 2010 2 EN 60974 10 2014 EN 55011 2009 A1 2010 3 EN 61000 3 11 2000 EN 2000 EN 61000 3 12 2011 3 EN 61000 3 11 2000 EN 2000 EN 61000 3 12 2011 and meets the essential requirements of...

Страница 19: ...the consignment NAME OF EQUIPMENT WELDING EQUIPMENT TYPE MODEL MIG 185 KRAMER Serial number HOLOGRAM SALE DATE NOTES STAMP AND SIGNATURE 1 The guarantee of the quality of the machine as manufacturer...

Страница 20: ...nd the customer acknowledges his signature 11 The warranty does not cover the activities foreseen in the manual the execution of which the user is obliged to own and at their own expense for example S...

Страница 21: ...or causing damage to the components niedokr caniem connections or over capacity spray guns 13 Improper use LOSS OF WARRANTY AS FOLLOWS Loss of warranty in the event 1 non compliance with the operating...

Страница 22: ...Page 22 with 23 Page 22 with 23 Page 22 with 23 Page 22 with 23 MANUAL KRAMER Technik MIG MMA 185 Date of adoption release date The scope of repairs Stamp and signature service...

Страница 23: ...Page 23 with 23 Page 23 with 23 Page 23 with 23 Page 23 with 23 MANUAL KRAMER Technik MIG MMA 185 12 NOTES 12 NOTES...

Отзывы: