5. The warranty on goods sold 

does not exclude, limit or suspend the 

5. The warranty on goods sold 

does not exclude, limit or suspend the 

the buyer's rights resulting from the provisions of the warranty for defects in the goods sold. 

6. disclosed defects during the warranty period will be removed in no more than 14 days from the date of delivery 

of the faulty device to the Service Importer. 

7. The advertised within the warranty of the machine should be delivered to the Seller with a full standard 

equipment, clean and - if the device has - with a clear plate. 

8. advertised device must be returned in the box properly packed protected against damage in transit needs to 

be determined if required "up - down" or "caution glass" 

9. The company skilled in the art does not accept complaints and returns sent to the address of the Company for 

downloading! 

10. The guarantee document is valid if you have correctly completed entries regarding: the date of sale, the 

name of the device sold, stamp and signature of the seller and the customer acknowledges his signature. 

11. The warranty does not cover the activities foreseen in the manual, the execution of which the user is obliged to 

own and at their own expense, for example. Start-up, maintenance, replacement batteries, and other supplies. 

12. Said faulty equipment and parts become the property of the Guarantor. 

REFUSAL OF COMPLAINTS: 

The guarantor may refuse to accept the complaint if: 

statement using the unit misused and 

instruction 

operation, 

delivery device dirty, no standard equipment, without the nameplate and seal or hologram 

determine the cause of the fault other than manufacturing or material defect inherent in the device, 

formal defects associated with the sales documents, 

as unfilled card 

Warranty, lack of proof of purchase. 

ARE NOT COVERED BY WARRANTY: 

1. The parts which, when aligned with the recommendations of operation are subject to wear and tear within the 

warranty period, such as welding torches, the mass handles, nozzles, burners, batteries, belts, filters, oil, 
electrodes, gaskets, o-rings, and other elements related to directly to the operation. 

2. Disadvantages caused by mechanical damage, thermal or chemical plant and equipment. 

3. Damage due to improper transport and storage, 
4. Damage related to work at too low or too high a temperature, 
5. Damage caused by faulty electrical installation, liquid or moisture electrical components water, 

6. Wrong connection to a power source (eg. Poor polarity, poor connection 230 or 400 V, there are no phases or too 

loosely clamped connection cables) 

7. Damage caused by overloading equipment overheating, 

8. Incorrect setting of the welding parameters, the interference in the control panel screw compressors. 

Содержание KRAMER 200

Страница 1: ......

Страница 2: ...scription of symbols 3 Destiny 6 Description of the device 6 Technical data 6 Support device 7 Process MIG MAG 9 Connecting the device to MMA 11 Description of the control panel 12 Control modes by pr...

Страница 3: ...oved face shields and welding shields Always use protective clothing designed for welders Metal splinters can injure your eyes Always use safety glasses Electrical shock can result in death Do not tou...

Страница 4: ...st be separated and protected from flammable materials and explosives The magnetic field can disrupt the functioning of pacemakers Before starting work consult your physician Do not weld at height wit...

Страница 5: ...The device should be used in accordance with the Regulation of the Minister of Economy of 27 04 2000r on health and safety at work welding Dz U No 40 item 470 The behavior of this manual and followin...

Страница 6: ...d double pulse and the option electrode welding MMA 4 TECHNICAL DATA 4 TECHNICAL DATA Parameter KRAMER MIG MAG PULSE BI 200 Voltage V 1 230 Current frequency Hz 50 60 Tolerance variations in the power...

Страница 7: ...WORK AND BEFORE WORK Before starting work you must specify the place where the device is to be operated Check voltage value phase and frequency of the supply current before switching the machine to th...

Страница 8: ...the gas burner nozzles and unscrew the contact tip Switch on the device Open wire welding torch so that it is simple ATTENTION Do not direct the tip of the welding torch in the direction of the face...

Страница 9: ...ing gases indicated by MIG MAG is one of the most widely used process for producing weldments Abbreviation MAG metal active gas includes in its description of the active shielding gases Abbreviation M...

Страница 10: ...electrode is in the form of the solid wire typically having a diameter of 0 6 to 1 2 mm and is fed continuously by a special supply system a speed of 2 5 m min and above The welding may be water coole...

Страница 11: ...A MMA welding with covered electrode To obtain a high quality weld the weld edges must first remove the rust and other contaminants In preparing the edges to take into account both the thickness of th...

Страница 12: ...ich prevents extinction of the arc When welding with coated electrodes at each pass should be removed from weld slag 8 Control Description 8 Control Description AND knob welding current Amps a test wi...

Страница 13: ...lding wire Control Mode Selection button torch ATTENTION For welding with a single and double pulse suggests a selection of special S4T to adjustable important welding parameters see chapter MODES CON...

Страница 14: ...lse welding P p pulse modulation The placement of the peak welding current mode pulse podr jnego Hotu Tension current take off The arc voltage ignition pdczas PU Power base Base voltage arc mode a dou...

Страница 15: ...time Preg and TIG arc welding Arch will be maintained as long as the button is held down After his release will extinguish the arc and spits gas at the set time Post 2 4T Czterotakt mode when you pre...

Страница 16: ...Slop to the final current Endi filling the crater Then terminate the arc and set time Post shielding gas will flow WELDING POINT SPOT In order to start spot welding SPOT select this option on the con...

Страница 17: ...open Using the knob V must be selected k rmym channel to be stored Approval of the selection nast puj after re pressing the V To exit the menu at any time by pressing the V 11 SYSTEM ERROR CODES 11 SY...

Страница 18: ...ould check if the vent is not blocked The distance between the welder and the welded object should not be less than 0 3m The operator should always pay attention to ventilation devices since they depe...

Страница 19: ...dust with clean compressed air If the unit is in working conditions in the smoke in the heavily polluted air every day remove accumulated dust Air pressure should be maintained at a level not to dama...

Страница 20: ...ocked Check that the end of the current contribution and the guide wire is selected according to the diameter and type of welding wire The device has stopped welding lit the lamp thermal protection at...

Страница 21: ...mentally friendly manner As the owner of the equipment should obtain information on approved collection systems from our local representative By following these guidelines protect environment and huma...

Страница 22: ...i tek shall not be liable for any errors or omissions We reserve the right to change the specifications of the products described at any time without prior notice ATTENTION The content of this manual...

Страница 23: ...12 EN 50445 2008 1 EN 60974 1 2012 EN 50445 2008 2 EN 60974 10 2014 EN 61000 3 11 2000 2 EN 60974 10 2014 EN 61000 3 11 2000 3 EN 61000 3 12 2011 3 EN 61000 3 12 2011 and meets the essential requireme...

Страница 24: ...TE NOTES STAMP AND SIGNATURE 1 The guarantee of the quality of the machine as manufacturer importer and distributor is 1 The guarantee of the quality of the machine as manufacturer importer and distri...

Страница 25: ...se for example Start up maintenance replacement batteries and other supplies 12 Said faulty equipment and parts become the property of the Guarantor REFUSAL OF COMPLAINTS The guarantor may refuse to a...

Страница 26: ...ty spray guns 13 Improper use LOSS OF WARRANTY AS FOLLOWS Loss of warranty in the event 1 non compliance with the operating instructions 2 misuse 3 overloading the machinery 4 operation without lubric...

Страница 27: ...Page 27 with 28 Page 27 with 28 Page 27 with 28 Page 27 with 28 MANUAL KRAMER BI pulse MIG MAG 200 Date of adoption release date The scope of repairs Stamp and signature service...

Страница 28: ...Page 28 with 28 Page 28 with 28 Page 28 with 28 Page 28 with 28 MANUAL KRAMER BI pulse MIG MAG 200 17 NOTES 17 NOTES...

Отзывы: