31
Standby Time Out (Minute)
This field specifies the length of a period of system inactivity (like hard disk or video)
while in full power on state. When this length of time expires, the system enters
Standby power state.
Available Options: Disabled, 1 Minute, 2 Minute, 4 Minute, and 8 Minute, up to 60
Minute.
Default setting: Disabled
Suspend Time Out (Minute)
This field specifies the length of a period of system inactivity (like hard disk or video)
while in Standby state. When this length of time expires, the system enters Suspend
power state.
Available Options: Disabled, 1 Minute, 2 Minute, 4 Minute, and 8 Minute, up to 60
Minute.
Default setting: Disabled
Throttle Slow Clock Ratio
When the system enter Suspend or standby mode, the CPU clock runs only part of
the time. You may select the percent of time that the clock runs.
Available Options: 0%-6.25, 25%37.5%, 75%87.5% and
93.75%-100%
Default setting: 50%-56.25%
IRQ3 ~IRQ15
This field specifies the power down mode of the system based on the device.
When the system does not receive signals from the device, it will enter the Power
Down mode immediately. To enable the power saving mode, select Monitor. To
disable it, select Ignore.