Installation
Instructions
11 <
<
<
<
Alternatively
use
the
exhaust
calculation
table.
(see
chapter
13).
The
alternatives
of
outlet
lengths
and
any
restrictors
are
set
out
in
the
restictor
table.
In
the
table
we
work
with
Start
Length
(STL)
Total
Vertical
Height
(TVH)
and
Total
Horizontal
Length
(THL).
Start
Length
(STL)
This
is
the
first
part
that
is
placed
on
the
fire
and
represents
a
certain
value
(Fig.
12.1,
12.2
and
12.3
A,
N,
F).
This
value
is
in
the
top
row
of
the
table
(see
table).
Total
Vertical
Height
(TVH)
TVH
is
the
difference
in
height
measured
from
the
top
of
the
unit
to
the
outlet;
it
can
be
measured
or
determined
from
the
building
plan.
For
clarification
see
the
TVH
indication
in
the
drawings.
(Fig.
12.1,
12.2
and
12.3:
TVH)
Total
Horizontal
Length
(THL)
THL
is
the
Total
Horizontal
Length
and
consists
of
elbows
and
pipes
which
are
entirely
in
the
horizontal
plane.
Elbows
I,
K
and
Q
and
the
elements
H,
J,
L,
M,
P
and
R
(Fig.
12.1
and
12.2).
Horizontal
length
The
horizontal
length
consists
of
the
elements
H,
J,
L,
M,
P
and
R
(Fig.
12.1
end
12.2).
Elbows
90°
in
the
horizontal
plane
Horizontal
bends
are
bends
which
are
entirely
in
the
horizontal
plane
(Fig.
12.1,
12.2
and
12.3
I,
K
and
Q).
Bends
45°
or
30°
in
the
horizontal
plane
Horizontal
bends
are
bends
which
are
entirely
in
the
horizontal
plane
Bends
Elbows
90°
vertical
to
horizontal
plane
These
are
90°
elbows,
which
proceed
from
horizontal
to
vertical
(Fig.
12.2
and
12.3
G,
O
and
S)
Bends
45°
or
30
°vertical
to
horizontal
plane
These
are
30°
or
45°
bends
with
a
vertical
offset
of
less
than
45°
(Fig.12.1
B
and
D).
Pipes
under
a
tilt
angle:
These
are
pipes
which
are
vertically
ascending
at
an
angle
of
30°
or
45°.
(Fig.
12.1
C).
Fill
in
only
in
combination
with
at
least
2
x
30
or
45°
bends
in
the
vertical
part.
Table:
See
the
table
at
the
right
vertical
(TVH)
and
horizontal
length
(THL).
For
“x”
and
if
the
values
are
outside
the
table,
then
the
combination
is
not
allowed.
Only
then
adjust
the
TVH
or
THL.
If
a
value
is
indicated,
check
that
the
calculated
STL
value
is
not
lower
than
indicated
in
the
table.
In
this
case
STL
must
be
adjusted.
The
found
value
indicates
the
width
of
the
restrictor
(“0”
means
no
restrictor).
Standard
is
a
restrictor
of
30mm
installed.
(Fig.
3.4).
Содержание Relaxed Premium XL
Страница 1: ...Relaxed Premium XL 40010949 14xx Relaxed Premium XL ENG ...
Страница 2: ...Installation Instructions 1 3 alternative finishes 1 1a 1 1b 1 1c ...
Страница 3: ...Installation Instructions 2 1 2 1 3 1 4 7 ...
Страница 4: ...Installation Instructions 3 1 9 1 5 1 6 B ...
Страница 5: ...Installation Instructions 4 2 1 2 2 2 3 3 1 3 2 3 3 3 4 ...
Страница 6: ...Installation Instructions 5 3 5 4 1 4 2 4 3 ...
Страница 15: ...Installation Instructions 14 12 Example Fig 12 1 Fig 12 2 Fig 12 3 ...
Страница 16: ...Installation Instructions 15 13 Calculation Sheet ...
Страница 17: ...Installation Instructions 16 ...
Страница 20: ...Installation Instructions 19 16 Dimensional drawings 16 1 Relaxed Premium L 348 Ext ...
Страница 21: ...Installation Instructions 20 16 2 Ventilation grid and control door ...
Страница 22: ...Installation Instructions 21 Dealer info ...