![Faber Relaxed Premium XL Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/faber/relaxed-premium-xl/relaxed-premium-xl_manual_535943010.webp)
Installation
Instructions
9 <
<
<
<
5
Removing
the
glass
Remove
the
mouldings,
see
Chapter
4.6.6
Place
the
suction
cups
on
the
glass.
Draw
the
sealing
cord
from
the
slot.
(Fig.
2.1).
Slide
the
glass
to
the
top
so
that
the
bottom
is
released
from
the
slot.
Now
pull
the
glass
out
and
gradually
down.
(Fig.
2.3).
6
Placing
the
decoration
material
It
is
not
permitted
to
use
other
or
to
add
more
material
in
the
combustion
chamber.
Keep
the
pilot
light
always
free
of
decoration
material!
Do
not
place
all
decoration
material
at
one
time
on
the
burner;
the
fabric
parts
can
block
it.
6.1
Log
set
Place
some
of
the
chips
on
the
burner
and
on
the
bottom.
Place
the
logs
as
specified.
(see
Fig.
(4.1
of
included
log
set
card)
Divide
the
rest
of
the
chips
on
the
burner
and
on
the
bottom.
Prevent
a
thick
layer
on
the
burner;
this
adversely
affects
the
fire
image.
6.2
Glow
wire
The
“
glow
wire
”
gives
a
decorative
glow
effect.
Pull
the
wool
well
apart
and
place
in
different
places
tufts
on
the
burner.
Please
note:
Do
not
use
the
glow
wire
near
the
pilot
flame!
This
can
cause
a
short
circuit
in
the
ignition
system!
6.3
Pebbles
Place
the
pebbles
on
the
burner
and
on
the
bottom.
(see
Fig.
4.2
and
4.3
of
included
wood
set
card).
Prevent
a
double
layer;
this
adversely
affects
the
fire
image.
Replace
the
glass
and
check
the
fire
image.
Start
the
fire
as
described
in
the
user
manual.
Check
if
the
flame
distribution
is
good.
Move
the
chips
if
necessary,
until
a
good
flame
distribution
is
achieved.
7
Checking
the
installation
7.1
Checking
the
main
burner
ignition,
pilot
flame
Ignite
the
fire
as
described
in
the
user
manual.
Check
that
the
pilot
flame
is
well
above
the
main
burner
and
not
covered
by
chips.
Check
the
ignition
of
the
main
burner
on
full
and
small
setting.
(ignition
must
be
smooth
and
quiet).
7.2
Checking
for
gas
leaks
Check
with
a
gas
leak
finder
or
spray
all
connections
and
pipes
for
gas
leakage.
7.3
Checking
the
burner
pressure
and
primary
pressure
Check
that
the
burner
pressure
and
primary
pressure
match
the
information
listed
in
the
manual,
Chapter
14
Technical
specifications.
Measuring
the
primary
pressure:
Close
the
shutoff
valve.
Turn
measuring
nipple
B
(see
Fig.
3.2)
some
turns
open
and
connect
a
measuring
hose
to
the
gas
regulator.
Take
this
measurement
at
highest
setting
of
the
fire
and
when
the
fire
is
set
to
pilot
light.
Do
not
connect
the
unit
if
the
pressure
is
too
high.
Measuring
the
burner
pressure:
Check
the
burner
pressure
only
with
proper
primary
pressure.
Turn
measuring
nipple
A
(see
Fig.
3.2)
some
turns
open
and
connect
a
measuring
hose
to
the
gas
regulator.
The
pressure
must
correspond
to
the
value
indicated
in
the
technical
specifications
of
this
manual.
In
case
of
deviation
contact
the
manufacturer.
Please
note:
Close
all
pressure
measuring
nipples
and
check
for
gas
leakage.
7.4
Checking
the
flame
image
Let
the
fire
burn
for
at
least
20
minutes
at
highest
setting
and
check
the
flame
for:
1.
Flame
distribution
2.
Colour
of
the
flames
Содержание Relaxed Premium XL
Страница 1: ...Relaxed Premium XL 40010949 14xx Relaxed Premium XL ENG ...
Страница 2: ...Installation Instructions 1 3 alternative finishes 1 1a 1 1b 1 1c ...
Страница 3: ...Installation Instructions 2 1 2 1 3 1 4 7 ...
Страница 4: ...Installation Instructions 3 1 9 1 5 1 6 B ...
Страница 5: ...Installation Instructions 4 2 1 2 2 2 3 3 1 3 2 3 3 3 4 ...
Страница 6: ...Installation Instructions 5 3 5 4 1 4 2 4 3 ...
Страница 15: ...Installation Instructions 14 12 Example Fig 12 1 Fig 12 2 Fig 12 3 ...
Страница 16: ...Installation Instructions 15 13 Calculation Sheet ...
Страница 17: ...Installation Instructions 16 ...
Страница 20: ...Installation Instructions 19 16 Dimensional drawings 16 1 Relaxed Premium L 348 Ext ...
Страница 21: ...Installation Instructions 20 16 2 Ventilation grid and control door ...
Страница 22: ...Installation Instructions 21 Dealer info ...