Manual ignition (by the installer) 

This action is intended for service purposes only! 
To do this the following procedure should be 
followed: 
 

 

Remove the ignition lead from the 
receiver (fig. 1.3-F) and place this on the 
gas valve (fig. 1.5-C). 

 

Turn the knob “B” clockwise with the 
arrow to the OFF position (fig. 1.5). 

 

Turn the dial “A” clockwise with the arrow 
in the MAN position (fig. 1.5). Now the 
pilot light valve “C” and the piezo-ignition 
E are accessible. 

 

Press the pilot flame valve “D” with a 
screwdriver and keep the valve pressed. 
Simultaneously press the piezo ignition 
“E” several times. The pilot flame will now 

ignite. If the pilot flame is burning, wait 
approximately 20 sec. before releasing the 
pilot valve. 

 

Now turn the dial “A” anticlockwise with 
the arrow to the ON position. (fig. 1.6). 

 

Now the flame height can be adjusted by 
turning the knob “B” anticlockwise past 
the ON position (fig. 1.6) This causes a 
rattling sound! 
 

 

Please note! 
When step burner, you can't switch between 
narrow and wide manually! 

 

 
 
 
 
 

 

Fault codes remote control 

Fault code 

Duration time 
fault code on 
display 

Symptom 

Possible cause 

F04 

4 sec. 

-

 

No pilot flame within 30 sec. 
(Attention! After 3 failed 
ignition attempts, error code 
F06 appears). 

-

 

No gas supply. 

-

 

Air in burner pipe pilot flame. 

-

 

No spark. 

-

 

Reversed polarity in thermocouple 
wiring. 

F06 

4 sec. 

-

 

3 failed ignition attempts within 
5 min. 

-

 

Fire doesn’t respond, no pilot 
flame. 

-

 

No gas supply. 

-

 

Air in burner pipe pilot flame. 

-

 

No spark. 

-

 

Reversed polarity in thermocouple 
wiring. 

F09 

4 sec. 

-

 

No electronic control of fire. 

-

 

The remote control isn’t paired with 
receiver (see section 4.3). 

Battery 
symbol (F40) 

Permanent 

-

 

Low battery voltage in remote 
control 

-

 

Replace batteries in remote control 
(see section 3.2). 

F46 

4 sec. 

-

 

Fire doesn’t respond. 
 
 

-

 

Intermittent response. 

-

 

No electronic control of fire. 

-

 

No or bad connection between 
remote control and receiver. (see 
section 4.3). 

-

 

Low battery receiver (see section 3.2). 

-

 

Power supply (6V adapter) is broken. 

 
 

 

TVH 

Содержание Mertik

Страница 1: ...User manual Symax Mertik ENG 40011927 1939...

Страница 2: ...l number This user manual is intended for the following gas fires MatriX 450 500 I II III MatriX 450 650 I II III MatriX 800 500 I II III MatriX 800 650 I II III MatriX 1050 500 I II III MatriX 1050 6...

Страница 3: ...User manual Symax 2 1 1 1 2 1 3 1 4 1 5 1 6 2 0...

Страница 4: ...ed around the fireplace As a fire is a source of heat hot air circulation is created As a result of natural air circulation moisture and not yet cured volatile components from paint building materials...

Страница 5: ...air them again Remote control The battery indication in top right corner of the display screen indicates the status of the batteries fig 2 0 After replacing the batteries the settings of the Thermosta...

Страница 6: ...o key operation Standard is one key operation To set this immediately press the key for 10 seconds after placing the batteries and wait until 1 or 2 flashes Release the key when the desired number of...

Страница 7: ...nfirm press the key or wait Now the light effect is adjusted Extended functions Countdown timer Please note The countdown timer works in Manual and Thermostatic mode only Max countdown time is 9 hours...

Страница 8: ...e key until OFF appears and the temperature flashes Press the or key to set the switch off temperature To confirm press the key Set day ALL flashes Press the or key to set the right day or period To c...

Страница 9: ...ast the ON position fig 1 6 This causes a rattling sound Please note When step burner you can t switch between narrow and wide manually Fault codes remote control Fault code Duration time fault code o...

Страница 10: ...User manual Symax 9...

Страница 11: ...User manual Symax 10...

Страница 12: ......

Отзывы: