background image

 

User manual Symax

 

7 < 

<

 

<

 

<

 

Turn on 
Press the   key until   appears in the display 
screen (first, the preset temperature will be 
displayed, then the room temperature). 
 
Turn off 
Press the   key until   disappears in the display 
screen. 
 
If the   or   keys are pressed (Manual mode), or 
the Program mode (key  ) is activated, the 
Thermostatic mode will be switched off. 
 

 

Program mode 

The Program mode can regulate the temperature 
once or twice for the ON and OFF temperature 
during a period of 24 hours. 
 
The following periods can be set: 

 

Week   

“ALL” 

 

Weekend 

“SA:SU” 

 

1 until 7 days 

“1, 2, 3, 4, 5, 6 or 7” 

 
The set temperature for Thermostatic mode is the 
temperature for the ON time in Program mode. 
Changing the temperature for Thermostatic mode 
also changes the ON time temperature in Program 
mode. 
 
The temperature for the ON and OFF time are the 
same for each day and for Program 1 and 2. 
 
Default settings: 
ON time temperature 

-21°C (70°F) 

OFF time temperature  

- “--“ (pilot flame only) 

 
Set temperature 

 

Press the   key until   
flashes. “ON” and the in 
Thermostatic mode set 
temperature appears. This 
can’t be changed now. 

 

Press the   key until “OFF” 
appears and the temperature 
flashes. 

 

Press the   or   key to set 
the switch-off temperature. 

 

To confirm press the   key. 

Set day 

 

“ALL” flashes. Press the   or 

 key to set the right day or 

period. 

 

To confirm press the   key. 
 
 
 
 

Set ON time Program 1 

 

 

1 and “ON” appears in 

the display screen and the 
hour flashes. 

 

Press the   or   key to set 
the switch-on hour. 

 

Press the   key to confirm 
and the minutes flashes. 

 

Press the   or   key to set 
the minutes for the “ON” 
time. 

 

To confirm press the   key. 

Set OFF time Program 1 

 

1 and “OFF” appears in 

the display screen and the 
hour flashes. 

 

The OFF time can be set in the 
same way as the ON time. 

 
 
 

Either continue to Program 2 or stop programming 
at this point and Program 2 remains deactivated. 
 
If ALL, SA: SU or daily timer are programmed for 
the switching-ON/OFF times and temperatures of 
Program 1 and 2, then these are the new standard 
times. To reset this, remove the batteries. 
 
Turn on 
Press the   key until 

 and 1 or 2, and ON or OFF 

appears on the display screen. 
 
Turn off 
Press the   key until 

 disappears from the 

display screen. 
 

 

Please note! 
If the   or   keys are pressed, or the 
Thermostatic mode (key  ) is activated, the 
Program mode will be switched off. 
 

 

ECO mode 

This feature is not applicable. 
 

 

Circulating fan operation 

This feature is not applicable. 
 

 

Содержание Mertik

Страница 1: ...User manual Symax Mertik ENG 40011927 1939...

Страница 2: ...l number This user manual is intended for the following gas fires MatriX 450 500 I II III MatriX 450 650 I II III MatriX 800 500 I II III MatriX 800 650 I II III MatriX 1050 500 I II III MatriX 1050 6...

Страница 3: ...User manual Symax 2 1 1 1 2 1 3 1 4 1 5 1 6 2 0...

Страница 4: ...ed around the fireplace As a fire is a source of heat hot air circulation is created As a result of natural air circulation moisture and not yet cured volatile components from paint building materials...

Страница 5: ...air them again Remote control The battery indication in top right corner of the display screen indicates the status of the batteries fig 2 0 After replacing the batteries the settings of the Thermosta...

Страница 6: ...o key operation Standard is one key operation To set this immediately press the key for 10 seconds after placing the batteries and wait until 1 or 2 flashes Release the key when the desired number of...

Страница 7: ...nfirm press the key or wait Now the light effect is adjusted Extended functions Countdown timer Please note The countdown timer works in Manual and Thermostatic mode only Max countdown time is 9 hours...

Страница 8: ...e key until OFF appears and the temperature flashes Press the or key to set the switch off temperature To confirm press the key Set day ALL flashes Press the or key to set the right day or period To c...

Страница 9: ...ast the ON position fig 1 6 This causes a rattling sound Please note When step burner you can t switch between narrow and wide manually Fault codes remote control Fault code Duration time fault code o...

Страница 10: ...User manual Symax 9...

Страница 11: ...User manual Symax 10...

Страница 12: ......

Отзывы: