background image

 

User manual MatriX I.T.C. Honeywell

 

5 < 

<

 

<

 

<

 

 

Dear user

 

Congratulations on your purchase of a Faber fire! A 
quality product from which you will experience 
warmth and atmosphere for many years. We 
recommend that you read this manual carefully 
before using the fireplace. If any problem arises 
despite our strict quality control, you can always 
contact your dealer or Glen Dimplex Benelux B.V. 

 

For any warranty claims, it is essential you first 
register your fireplace. During this registration, 
you’ll find all information regarding our warranty. 
 
Details about your fire can be found on page 3 or 
in the App. (See section 6.1). 
 
You can register your fire at: 

www.faberfires.com

 

 
Glen Dimplex Benelux B.V. 
Address: Saturnus 8 
 

NL-8448 CC 
Heerenveen 

Tel: 

+31 (0)513 656 500  

Email:  [email protected] 
Info: 

www.faberfires.com

 

 

Introduction 

Installation and maintenance of the appliance must 
be carried out by a professional with proven 
knowledge and competence. A professional takes 
into account all technical aspects such as heat 
radiation and gas connection as well as flue gas 
exhaust requirements. 
 
Where the installation instructions are not clear, 
national/local regulations must be followed. 

 

Check 

Check the fire for transport damage and 
immediately report any damage to your supplier. 

 

CE Declaration 

We hereby declare that Glen Dimplex Benelux B.V. 
released Faber gas-atmosphere heating appliance 
by its design and construction method complies 
with the Regulation (EU): 2016/426 and (EU) 
2015/1188. 

 

Safety instructions for the user 

 

 

Please note! 
It is advisable to always install a screen for the 
fireplace if children, elderly or disabled people 
are present in the same room as the fireplace. 
If regularly vulnerable persons can be present 
in the room without supervision, sufficient 
protection must always be placed around the 
fireplace. 

 

As a fire is a source of heat, hot air 
circulation is created. As a result of 
natural air circulation, moisture and not 
yet cured volatile components from paint, 
building materials and carpeted floors are 
included in this air circulation. These parts 
can settle as soot on cold surfaces. The 
moment, using the fire for the first time, 
depends on various circumstances. 
Consult your installer/dealer about this 
matter. 

 

The appliance is designed for atmospheric 
and heating purposes, meaning that all 
visible surfaces, including the glass, can 
become hotter than 100 ° C. An exception 
for free standing models is the underside 
of the fireplace and the control buttons. 

 

The fire cannot be used when: the glass is 
damaged or removed or when the 
combustion chamber is open. 

 

Do not place flammable materials inside 
the combustion chamber. 

 

Do not place extra imitation wood or 
other material on the burner or in the 
combustion chamber. 

 

Do not place any combustible materials 
within 0,5m of the radiation area of the 
fire.  

 

Do not allow children to use the remote 
control without supervision. 

 

Using the fire for the first time 

Provide extra ventilation and open all the windows 
of the room during the initial start-up of the fire. 
Let the fire burn at the highest setting for a few 
hours so that the paint gets the chance to harden 
and any released vapours are safely removed. Keep 
vulnerable people and pets out of this room during 
this process. 

 

Cleaning and maintenance 

The device must be cleaned and checked by a 
qualified specialist to ensure the safe use and to 
guarantee a long service life. 
The outside of the fire can be cleaned with a clean 
damp cloth. 
 
Cleaning of the glass 
Remove the glass as described in the installation 
instructions. The glass can be cleaned with Faber 
glass polish. This is a specially formulated cleaning 
agent that can be ordered at authorised Faber 
dealers. Never use aggressive cleaning agents or 
abrasive products. 
 

 

Please note! 
Avoid fingerprints on the glass, these are no 
longer removable once the fire is used. 

Содержание MatriX 800/400 I

Страница 1: ...User manual MatriX I T C Honeywell ENG Intelligent Technical Controller 40011722 2141...

Страница 2: ...I III 2 MatriX 800 500 I II III H MatriX 800 500 RD ST LL MatriX 800 500 RD H ST H MatriX 800 650 I II III MatriX 800 650 I II III 2 MatriX 800 650 I II III H MatriX 1050 400 I II III MatriX 1050 500...

Страница 3: ...User manual MatriX I T C Honeywell 3 2 4 3 6 1 5 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 2 0 2 1 2 2 2 3...

Страница 4: ...User manual MatriX I T C Honeywell 4 2 4 2 5 2 6 2 7 2 8 2 9...

Страница 5: ...fire is a source of heat hot air circulation is created As a result of natural air circulation moisture and not yet cured volatile components from paint building materials and carpeted floors are incl...

Страница 6: ...in immediately after checking the safety system and will return to the position in which the device was before the test Please note If it is not possible anymore to operate the fire using the remote c...

Страница 7: ...mitting user command Remote Control repeats command max 4 times if the command is not confirmed by the I T C LED flashes orange 4 times o 1 or more active I T C warnings To be read in the App LED flas...

Страница 8: ...urement of the I T C with your own home thermostat At this setting you specify the temperature difference of the I T C from your own home thermostat Via App Menu Settings Calibration Room temperature...

Страница 9: ...Campfire A 13 minute animation of a real campfire with flames continuously varying in height and a modulating glow effect variation The fire starts with a slightly yellowish weak glow effect Slowly t...

Страница 10: ...ing will be avoided Setting of clock thermostat The latter is switched OFF by default and can be switched ON only if the manual mode is switched ON Setting of clock program The clock thermostat has a...

Страница 11: ...o light blue Release the button and then briefly press the pairing button again All connections have now been erased from the memory In order to operate the fireplace the remote control must be connec...