background image

 

User manual MatriX I.T.C. Honeywell

 

6 < 

<

 

<

 

<

 

 

Operation I.T.C. “Intelligent Technical 
Controller” (fig. 1.4) 

The I.T.C. controls, monitors, records the 
consumption and if necessary, gives warning and 
error codes. The I.T.C. is not connected to the 
internet and not accessible to third parties from 
the outside. Only in combination with the optional 
available Domotica Interface Unit is it possible, if 
desired, to realise connection at a great distance. 
 
Control is possible with remote control, 
Smartphone or Tablet. All 3 use a Bluetooth 
connection with the fire. The latter has a limited 
range so that you need to be in the vicinity of the 
fire at all times. 
 
Starting procedure 
Starting the fire is done according to a built-in 
procedure. This procedure may differ per type of 
fire. During this procedure no commands can be 
entered. This is shown on the remote control by a 
white flashing LED and in the App this will be 
visible on the display. If a start-up procedure is 
aborted by the user or the fire does not ignite at 
the end of the start-up procedure, then there is a 
waiting period of 30 sec. after switching off before 
it will be possible to restart. The waiting time 
increases in case of multiple starting attempts.  
After 3 full attempts, the I.T.C. is blocked for at 
least half an hour. The I.T.C. restores itself after 
this half hour. The waiting period is visible in the 
App. 
If during normal use the fire is switched off it is 
possible to switch it on again after 15 seconds.  
 
Automatic internal control of the electronics 
The burner control automatically checks the 
correct operation twice per 24 hours. After 12 
hours the first check takes place, but this is skipped 
if the device is actually burning. If the device is 
burning at the second attempt 12 hours later, the 
device is switched off and switched on again 
immediately after checking the safety system and 
will return to the position in which the device was 
before the test. 
 

 

Please note! 
If it is not possible anymore to operate the fire 
using the remote control or App, the fire can 
be switched on/off with the on/off button on 
the I.T.C., see fig. 1.4. (The latter is located 
behind the small service door). 

 
Fire OFF: Press On/Off button briefly. 
Fire ON: Press and hold On/Off button until the 
LED turns green. 
 

(If released earlier the start is interrupted). 
At pressing longer, the flame will change from low 
to high and from narrow to wide. Release the 
button at the moment when the desired position 
has been reached. If the button is not released, the 
fire will automatically switch off.  
(If the button is pressed longer than 5 min., the 
I.T.C. shows an error message that the button 
might be broken and that service is desired). 

 

Remote control (fig. 1.0) 

The remote control is already connected to the 
I.T.C. so that the fire is ready for use. If this is not 
the case, follow the instructions in accordance with 
section 4.1. With the remote control all the basic 
functions can be activated. For the operation of 
the thermostat function and to change settings, it 
is necessary to use the Faber App on Smartphone 
or Tablet. The remote control also functions as a 
room thermostat and must therefore be placed in 
a suitable place in the supplied cradle.  
(See chapter 8). 
 
Remote control button functions 

1:

 

OFF 

(top left) 

2:

 

ON 

(top right) 

3:

 

Fire lower  

(centre left) 

4:

 

Fire higher  

(centre right) 

5:

 

Switching step mode(s) 

(bottom left) 

6:

 

Glow effect on/off  

(bottom right) 

 
The function of button 6 is only available with an 
installed Symbio LED module or HPL module. 
The LED intensity can be customised by pressing 
and holding button 6 and simultaneously briefly 
pressing button 3 or 4 one or more times. This new 
setting is saved. 
 

 

Please note! 
The fireplace is switched off if the remote 
control: 

 

is out of reach of the fireplace; 

 

is no longer connected to the fireplace; 

 

the batteries are empty. 
 

 

Содержание MatriX 800/400 I

Страница 1: ...User manual MatriX I T C Honeywell ENG Intelligent Technical Controller 40011722 2141...

Страница 2: ...I III 2 MatriX 800 500 I II III H MatriX 800 500 RD ST LL MatriX 800 500 RD H ST H MatriX 800 650 I II III MatriX 800 650 I II III 2 MatriX 800 650 I II III H MatriX 1050 400 I II III MatriX 1050 500...

Страница 3: ...User manual MatriX I T C Honeywell 3 2 4 3 6 1 5 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 2 0 2 1 2 2 2 3...

Страница 4: ...User manual MatriX I T C Honeywell 4 2 4 2 5 2 6 2 7 2 8 2 9...

Страница 5: ...fire is a source of heat hot air circulation is created As a result of natural air circulation moisture and not yet cured volatile components from paint building materials and carpeted floors are incl...

Страница 6: ...in immediately after checking the safety system and will return to the position in which the device was before the test Please note If it is not possible anymore to operate the fire using the remote c...

Страница 7: ...mitting user command Remote Control repeats command max 4 times if the command is not confirmed by the I T C LED flashes orange 4 times o 1 or more active I T C warnings To be read in the App LED flas...

Страница 8: ...urement of the I T C with your own home thermostat At this setting you specify the temperature difference of the I T C from your own home thermostat Via App Menu Settings Calibration Room temperature...

Страница 9: ...Campfire A 13 minute animation of a real campfire with flames continuously varying in height and a modulating glow effect variation The fire starts with a slightly yellowish weak glow effect Slowly t...

Страница 10: ...ing will be avoided Setting of clock thermostat The latter is switched OFF by default and can be switched ON only if the manual mode is switched ON Setting of clock program The clock thermostat has a...

Страница 11: ...o light blue Release the button and then briefly press the pairing button again All connections have now been erased from the memory In order to operate the fireplace the remote control must be connec...

Страница 12: ......

Отзывы: