![Faber Hestia Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/faber/hestia/hestia_installation-manual_535913022.webp)
21 <
<
<
<
UK
IRL
Appendix D: Technical specifications Flatburner
Flatburner
Flatburner
Country
UK / IRL
UK / IRL
Cat
II 2E+3+
II 2H3+
Appliancetype
C11 of C31
C11 of C31
Reference gas
G20
G31
Input (nett)
kW
8.8
7.6
Efficiency class
2
2
Inlet pressure
Mbar
20
37
Gas rate*
l/h
925
350
Gas rate*
gram/h
660
Working pressure (high)
Mbar
11.0
27.5
Injector size
Mm
Bray 900
Bray 280
Reduced input restraint
Mm
2.10
1.30
Pilot assembly
SIT 145
SIT 145
Code
Nr.36
Nr.23
Flue system
Flue size
Mm
100-150
100-150
Std. Flue restrictor
Mm
30
30
Gas control
GV 36
C5AOEHC68M
C5AODHC68M
Gas connection
Nut/olive
8 mm
8 mm
* at 15ºC and 1013 mbar
Содержание Hestia
Страница 1: ...Hestia Installation Guide IRL UK 40010610 0746 ...
Страница 2: ...1 UK IRL Content 1 1 1 2 1 3 1 4 1 5 1 6 A B D C ...
Страница 3: ... 2 UK IRL Hestia with Wirdum Surround 2 1 2 2 2 3 2 4 2 5 2 6 ...
Страница 4: ...3 UK IRL Hestia with Jellum Surround 3 1 3 2 3 3 3 4 3 5 3 6 ...
Страница 5: ... 4 UK IRL Hestia Frameless 3 1 3 2 3 3 3 4 3 5 3 6 ...
Страница 6: ...5 UK IRL De mounting the Glass 4 1 4 2 4 3 4 4 4 5 ...
Страница 24: ...23 UK IRL Appendix F Dimensions Hestia Frameless ...
Страница 25: ... 24 UK IRL Appendix G Dim Hestia with Jellum surround ...
Страница 26: ...25 UK IRL Appendix H Dim Hestia with Wirdum surround ...
Страница 27: ... 26 UK IRL ...