Installation requirements
Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of
importance that you do not use the appliance shortly after a renovation of the home. Due
to the natural circulation of air, moist and volatile components from paint, building
materials, carpet etc. will be attracted to the lit appliance. These components can settle
onto cold surfaces in the form of soot.
As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed
too near the appliance may become scorched or discoloured. This should be born in mind
when installing the appliance.
3.1
Builders opening and surround
The appliance can be installed in a non-combustible fireplace or a builders opening. This
could be either an existing builders opening or a new made prefab builders opening.
In both cases keep the following in mind:
•
do not place the appliance on combustible materials or carpets
•
the (false) chimney breast has to be made of non-combustible material (e.g.
Promatect)
•
do not place the lintel, surround or marble stone directly onto the appliance. If
possible, apply a lintel made of cement or something similar
•
always ventilate the space above the appliance. Use a Faber ventilation grid
•
to avoid cracking, the plaster has to dry for at least 1 day per millimetre plaster
•
to avoid discolouring the plaster has to be heat resistant to min. 100 °C
•
in case of a Wirdum surround the front of the appliance has to stick 123 mm out of
the wall (see appendix J for dimensions sketches)
3.2
Flue requirements
The appliance is of the type C11/C31. The appliance will need to be supplied with the
approved Faber flue pipes and terminal, it is not possible to supply your own. The
minimum effective height of the flue system must be 1 meter.
Flue routing:
•
a horizontal extension with elbows is allowed for a maximum of 4 meters (Hestia
with flatburner) or 6 meter (Hestia with logburner)
•
vertical max. 12 meters (without horizontal extensions only)
Содержание Hestia
Страница 1: ...Hestia Installation Guide IRL UK 40010610 0746 ...
Страница 2: ...1 UK IRL Content 1 1 1 2 1 3 1 4 1 5 1 6 A B D C ...
Страница 3: ... 2 UK IRL Hestia with Wirdum Surround 2 1 2 2 2 3 2 4 2 5 2 6 ...
Страница 4: ...3 UK IRL Hestia with Jellum Surround 3 1 3 2 3 3 3 4 3 5 3 6 ...
Страница 5: ... 4 UK IRL Hestia Frameless 3 1 3 2 3 3 3 4 3 5 3 6 ...
Страница 6: ...5 UK IRL De mounting the Glass 4 1 4 2 4 3 4 4 4 5 ...
Страница 24: ...23 UK IRL Appendix F Dimensions Hestia Frameless ...
Страница 25: ... 24 UK IRL Appendix G Dim Hestia with Jellum surround ...
Страница 26: ...25 UK IRL Appendix H Dim Hestia with Wirdum surround ...
Страница 27: ... 26 UK IRL ...