Instruction for Installation 

4.1

 

Gas Connection 

Installation pipes should be in accordance with BS 6891. Pipe work from the meter to the 

appliance must be of adequate size. 

The complete installation including the meter must be tested for soundness and purged as 

described in the above code. 

A means of isolation must be provide in the supply to facilitate servicing. The connection 

should be made in 8 mm copper or similar semi flexible tube. (max 1 meter). Ensure that 

the gas pipe does not interfere with the removal or replacement of the burner tray or of 

the controls. The gas connection is nut and olive suitable for 8 mm pipe. 

 

4.2

 

Preparing the appliance 

Remove the packaging and the pallet under the appliance.  

Adjust the total height of the appliance considering the way the appliance will be placed 

(see appendix H,J & K). For reasons of transportation the height is pre-adjusted to high.  

There are two ways to adjust the height: 

ƒ

 

Rough adjustment: by removing the nut and bolt. Shift the leg 30mm and replace 

the nut and bolt 

ƒ

 

Fine adjustment: by adjusting the couple legs 

 

4.3

 

Placing the appliance 

ƒ

 

Check paragraph 3.1 before commencing installation 

ƒ

 

If possible, first place the appliance before assembling the flue 

ƒ

 

Check if the floor and wall are sufficiently level and perpendicular. If not, you 

should fix this 

ƒ

 

Prepare the gas connection, see paragraph 4.1 

ƒ

 

Position the firebox in the fireplace opening. Make sure that the appliance is level 

ƒ

 

Check the appliance height by moving the control cover drawer. There should be a 

clearance of several millimetres (see appendix J & K)between the drawer and the 

floor 

ƒ

 

Fasten the appliance to the back wall using the four slidable positioning lips on top 

and on either side of the appliance 

ƒ

 

Assemble the flue system onto the firebox (see appendix C) 

Содержание Hestia

Страница 1: ...Hestia Installation Guide IRL UK 40010610 0746 ...

Страница 2: ...1 UK IRL Content 1 1 1 2 1 3 1 4 1 5 1 6 A B D C ...

Страница 3: ... 2 UK IRL Hestia with Wirdum Surround 2 1 2 2 2 3 2 4 2 5 2 6 ...

Страница 4: ...3 UK IRL Hestia with Jellum Surround 3 1 3 2 3 3 3 4 3 5 3 6 ...

Страница 5: ... 4 UK IRL Hestia Frameless 3 1 3 2 3 3 3 4 3 5 3 6 ...

Страница 6: ...5 UK IRL De mounting the Glass 4 1 4 2 4 3 4 4 4 5 ...

Страница 7: ...sioning functional checks 15 5 1 Pilot ignition check 15 5 2 Check functional burner and pilot burner 15 6 Handing over final check and customer briefing 16 7 Servicing 16 7 1 Routine anual servicing 16 7 2 Cleaning the glass 16 7 3 Cleaning the combustion chamber and burner 17 7 4 Cleaning the Surround 17 Appendix A Example calculation 18 Appendix B Flue restrictor 19 Appendix C Installation of t...

Страница 8: ...sting builders opening or false chimney breast in combination with the Jellum 670 surround in combination with the Wirdum 670 surround Special features Room sealed appliance inlet and outlet are led to the outside using a natural draught concentric pipe system 100 mm 150 mm no power fan required Air supply and flue gases go to outside atmosphere through wall or roof A maximum horizontal extension ...

Страница 9: ...al safety It is the law in the UK that all gas appliances are installed by a competent person in accordance with the Gas Safety Installation and Use Regulations as amended the relevant British Standards for Installation work Building Regulations Codes of Practice and the manufacturers instructions Always use an additional guard if there are elderly infirm or children in the same room of the applia...

Страница 10: ... place the appliance on combustible materials or carpets the false chimney breast has to be made of non combustible material e g Promatect do not place the lintel surround or marble stone directly onto the appliance If possible apply a lintel made of cement or something similar always ventilate the space above the appliance Use a Faber ventilation grid to avoid cracking the plaster has to dry for ...

Страница 11: ...each 90 degree bend which is in the horizontal area counts for 2 meter 2 each 45 degree bend which is in the horizontal area counts for 1 meter 3 elbows and bends at the transition from horizontal to vertically are not to be counted 4 the wall mounted terminal counts for 1 meter 3 3 Flue restrictor If applicable in the table of appendix B is also stated the size of a flue restrictor This restricto...

Страница 12: ...ance will be placed see appendix H J K For reasons of transportation the height is pre adjusted to high There are two ways to adjust the height Rough adjustment by removing the nut and bolt Shift the leg 30mm and replace the nut and bolt Fine adjustment by adjusting the couple legs 4 3 Placing the appliance Check paragraph 3 1 before commencing installation If possible first place the appliance be...

Страница 13: ...ed Check that all the parts supplied in the crate are complete and undamaged Lay them out in a safe place so that you have a clear idea of what the various parts are As far as possible measure the dimensions using the drawing of the fireplace see Appendix J or K Smooth the floor using a suitable screed Be careful with limestone fireplaces you may have to seal the hearth or lay plastic sheet undern...

Страница 14: ...must also be able to absorb pressure at right angles onto the backing wall We therefore recommend a brickwork structure Saw the filler pieces to the right size The size depends upon the way in which the hearth is fitted in relation to the fireplace The components may be fastened together using acid free silicone paste or two component marble adhesive Silicone paste takes longer to set and so gives...

Страница 15: ... happens in reversed order Turn the glass carefully with the leftside towards the appliance Be sure that the glass slides behind the glass clamps at the left side Slide the glass as far as possible to the left Simultaneously turn and lift the glass towards the appliance till it closes the combustion chamber Check that the glass is positioned on the upperside of the glass clamp Slide the glass as m...

Страница 16: ...d pressure Perform this measuring when the appliance burns on full capacity and when only the pilot ignition burns When the pressure is too low check if the gas pipes are made of material with the right diameter When the pressure is too high more than 5 mBar overpressure you may not install the appliance and you should contact your gas company Always check the burner pressure when the functional p...

Страница 17: ...f the gas supply before commencing any servicing Always test for gas soundness after refitting the appliance 7 1 Routine anual servicing Clean if necessary a the pilot system b the burner c the combustion chamber d the glass Check the log layout and replace the embers if applicable Do the operating test as described in chapter 6 Check the flue system and terminal for damage and soundness visual in...

Страница 18: ...he distribution of the flame if so then replace the burner Remove the front glass and log holder if applicable Break the gas supply at the control valve Unscrew the burner assembly and take them out of the combustion chamber Replace the burner assembly after cleaning 7 4 Cleaning the Surround Clean the Surround using a dry non scratch cloth or a vacuum cleaner Be careful Do not use cleaning agents...

Страница 19: ...mounted terminal 1 m Total effective height 2 m According to the table in Appendix B is this situation allowed without a flue restrictor Please remove the flue restrictor Calculation 2 Calculation horizontal extension fig 2b Flue length J L 0 5 0 5 1 m Elbows K M 2m 2m 4 m Terminal 1 m Total horizontal extension 6 m Calculation effective height Hvert Flue length H 1 m According to the table in App...

Страница 20: ... x 0 5 x X x x x x x 1 0 0 0 x x x X 1 5 0 0 0 0 x x X 2 30 0 0 0 0 x x 3 30 30 0 0 0 0 x 4 40 30 30 0 0 0 X 5 40 40 30 30 0 0 X 6 50 40 40 30 30 0 x 7 50 50 40 40 30 30 x 8 60 50 50 40 40 x x 9 60 60 50 50 x x x 10 65 60 60 x x x x 11 65 65 x x x x x Real vertaical height m 12 65 x x x x x x Horizontale length m Hestia Logburne 0 1 2 3 4 5 6 0 X x x x x x x 0 5 0 0 x x x x x 1 0 0 0 0 x x X 1 5 3...

Страница 21: ...mp every 2m so the weight of the pipes is not resting onto the appliance The outside of the pipe can become hot 140 degrees Stay 50 mm away from wall surface or sealing Make sure to provide sufficiently heat resistant isolation when going through the wall or roof Because of expansion or cooling down the concentric pipes can turn loose It is recommended to fix the spring clip with a self tapping sc...

Страница 22: ...iency class 2 2 Inlet pressure Mbar 20 37 Gas rate l h 925 350 Gas rate gram h 660 Working pressure high Mbar 11 0 27 5 Injector size Mm Bray 900 Bray 280 Reduced input restraint Mm 2 10 1 30 Pilot assembly SIT 145 SIT 145 Code Nr 36 Nr 23 Flue system Flue size Mm 100 150 100 150 Std Flue restrictor Mm 30 30 Gas control GV 36 C5AOEHC68M C5AODHC68M Gas connection Nut olive 8 mm 8 mm at 15ºC and 101...

Страница 23: ...Efficiency class 2 2 Inlet pressure mbar 20 37 Gas rate l h 790 293 Gas rate gram h 550 Working pressure high mbar 11 5 29 6 Injector size mm 1 50 0 90 Reduced input restraint mm 1 80 1 10 Pilot assembly SIT 160 SIT 160 Code Nr 51 Nr 30 Flue system Flue size mm 100 150 100 150 Std Flue restrictor mm 30 30 Gas control GV 36 C5AOEHC68M C5AODHC68M Connection Nut olive 8 mm 8 mm at 15º C and 1013 mbar...

Страница 24: ...23 UK IRL Appendix F Dimensions Hestia Frameless ...

Страница 25: ... 24 UK IRL Appendix G Dim Hestia with Jellum surround ...

Страница 26: ...25 UK IRL Appendix H Dim Hestia with Wirdum surround ...

Страница 27: ... 26 UK IRL ...

Страница 28: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 40010610 0746 ...

Отзывы: