VENTING   REQUIREMENTS

Determine which venting method is best for your application.  

Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should 

be kept to a minimum to provide efficient performance.  The 

size of the ductwork should be uniform.  Do not install two el-

bows together.  Use duct tape to seal all joints in the ductwork 

system.  Use caulking to seal exterior wall or floor opening 

around the cap.

Flexible ductwork is not recommended.  Flexible ductwork 

creates  back  pressure  and  air  turbulence  that  greatly 

reduces performance.

Make sure there is proper clearance within the wall or floor for 

exhaust duct before making cutouts.  Do not cut a joist or stud 

unless absolutely necessary.  If a joist or stud must be cut, then 

a supporting frame must be constructed. 

FOR MORE SPECIFIC DUCTWORK INFORMATION, GO 

TO PAGE 4.

WARNING - To Reduce The Risk Of Fire, Use Only Metal 

Ductwork.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a 

separate 15 amp fused circuit.  A time-delay fuse or circuit 

breaker is recommended.  The fuse must be sized per local 

codes in accordance with the electrical rating of this unit as 

specified on the serial/rating plate located inside the unit near the 

field wiring compartment.  THIS UNIT MUST BE CONNECTED 

WITH COPPER WIRE ONLY.  Wire sizes must conform to the 

requirements of the National Electrical Code, ANSI/NFPA 70 

- latest edition, and all local codes and ordinances.  Wire size 

and connections must conform with the rating of the appliance.  

Copies of the standard listed above may be obtained from: 

 

National Fire Protection Association

 

Batterymarch Park

 

Quincy, Massachusetts  02269

• Venting system MUST terminate outside the 

home.

• DO NOT terminate the ductwork in an attic or 

other enclosed space.

• DO NOT use 4" laundry-type wall caps.

• Flexible-type ductwork is not recommended.

• DO NOT obstruct the flow of combustion and 

ventilation air.

• Failure to follow venting requirements may result 

in a  fire.

This appliance should be connected directly to the fused discon-

nect (or circuit breaker) through flexible, armored or nonmetallic 

sheathed copper cable.  Allow some slack in the cable so the 

appliance can be moved if servicing is ever necessary.  A UL 

Listed, 1/2" conduit connector must be provided at each end 

of the power supply cable (at the appliance and at the junction 

box).

When making the electrical connection, cut a 1   1/4" hole in the 

wall.  A hole cut through wood must be sanded until smooth.  A 

hole through metal must have a grommet. 

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC 

SHOCK, do not use this fan with any solid-state speed 

control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI

-

CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:  Use this unit only in the manner intended 

by the manufacturer.  If you have any questions, contact 

the manufacturer.

Before  servicing  or  cleaning  unit,  switch  power  off  at 

service panel and lock the service disconnecting means 

to  prevent  power  from  being  switched  on  accidentally.  

When the service disconnecting means cannot be locked, 

securely fasten a prominent warning device, such as a tag, 

to the service panel.

CAUTION: For General Ventilating Use Only.  Do Not Use To 

Exhaust Hazardous  or  Explosive Materials and Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI

-

CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING: Installation Work And Electrical Wiring Must 

Be Done By Qualified Person(s) In Accordance With All 

Applicable  Codes  And  Standards,  Including  Fire-Rated 

Construction.  

Sufficient air is needed for proper combustion and exhaust

-

ing of gases through the flue (chimney) of fuel burning 

equipment  to  prevent  backdrafting.    Follow  the  heating 

equipment manufacturer's guideline and safety standards 

such as those published by the National Fire Protection 

Association (NFPA), and the American Society for Heating, 

Refrigeration and Air Conditioning Engineers (ASHRAE), 

and the local code authorities.

When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.

   WARNING

• Electrical ground is required on this rangehood.

• If cold water pipe is interrupted by plastic, 

nonmetallic gaskets or other materials, DO NOT 

use for grounding.

• DO NOT ground to a gas pipe.

• DO NOT have a fuse in the neutral or grounding 

circuit.  A fuse in the neutral or grounding circuit 

could result in electrical shock.

• Check with a qualified electrician if you are in doubt 

as to whether the rangehood is properly grounded. 

• Failure to follow electrical requirements may result 

in a fire.   

   WARNING

For residential use only.

!

!

Cold Weather installations

An additional back draft damper should be installed to minimize 

backward cold air flow and a nonmetallic thermal break should 

be installed to minimize conduction of outside temperatures 

as part of the vent system. The damper should be on the cold 

air side of the thermal break. The break should be as close as 

possible to where the vent system enters the heated portion 

of the house.

Содержание Dama Isola

Страница 1: ...ejamaislaisser un élément de la table de cuisson fonctionner sans surveillance à la puissance de chauffage maximale un renversement débordement de matière graisseuse pourrait provoquer une inflammation et le génération de fumée Utiliser toujours une puissance de chauffage moyenne ou basse pour le chauffage d huile b Veiller à toujours faire fonctionner le ventilateur de la hotte lors d une cuisson...

Страница 2: ...ut a 1 1 4 hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRI CAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you...

Страница 3: ...ritédufournisseurtelsqueceuxpubliés par l Association Nationale de la Sauvegarde contre l Incendie et l Association Américaine d Ingénieurs de Chauffage Frigorifaction et Air Climatisé ainsi que les codes municipaux En perçant un mur veillez à ne pas perforer un autre fil électrique Une ventilateur à évacuation extérieure doit être raccordée à l extérieur AVERTISSEMENT Le système d évacuation DOIT...

Страница 4: ...crews on the outside bottom of the chimney cover Remove the UPPER CHIMNEY COVER C from the CHIMNEY SUPPORT F by removing the 2 philips screws on the outside top of the chimney cover CALCULATE THE DUCTRUN LENGTH The ductrun should not exceed 35 equivalent feet if ducted with the required minimum of 6 roundduct Calculatethelengthoftheductwork by adding the equivalent feet in FIGURE 2 for each piece ...

Страница 5: ... section of the support structure FIGURE 5 needs to be removed Out of the box the minimum chimney length is 32 not27 asshowninthedimensional diagram Add 5 to all minimum ceiling heightcalculations ifkeepingthemiddle section in place Contact Faber at 508 358 5353 for more information DUCTED INSTALLATION DIMENSIONS vented to the outside PLAN THE INSTALLATION This rangehood can be installed as either...

Страница 6: ...udes an additional support structure which adds 27 1 2 to the various ceiling heights in FIGURE 6 upper chimney cover ductless lower chimney cover canopy cabinet base x distancefromhoodtocooktop varies depending on installation min 24 suggested max 30 also consult cooktop manufacturer s recommendation 8 3 8 min 15 3 8 max 23 5 8 36 FIGURE 6 DUCTLESS DIMENSIONS x min max ceiling height examples x 3...

Страница 7: ...OVER C in FIGURE 11 attaches using two screws provided GinFIGURE11 If using the High Ceiling Chimney Kit use the UPPERCHIMNEYCOVER supplied with the kit Slide up and attach the UPPER CHIMNEY COVER 2 Attachtheductworktothe DAMPER MinFIGURE1 Make sure to seal all joints with duct tape to prevent leaks 3 The LOWER CHIMNEY COVER B in FIGURE 11 attaches using two screws provided G in FIGURE 11 Install ...

Страница 8: ...IGURE 12 FIGURE 14 6 Install the grease filters FIGURE 15 FIGURE 15 7 Turn the power supply on Turn on blower and lights If the rangehood does not operate check that the circuit breaker is not tripped or the house fuse blown If the unit still does not operate disconnect the power supply and check that the wiring connections have been made properly 5 Connect the CONTROL CABLES together as indicated...

Страница 9: ...develop proper airflow Allow the unit to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen Cleaning Thestainlesssteelgreasefiltersshouldbecleanedfrequentlyin hot detergent solution or washed in the dishwasher Stainless steelcleanershouldbeusedonstainlessrangehoods Abrasives and scouring agents can scratch stainless steel finishes and should not be ...

Страница 10: ...lumbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than normal single family household use 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes ...

Страница 11: ...ONGUEUR DU CONDUIT La longueur du conduit ne doit jamais excéder 35pis ils agitdeconduitrondde6po Calculer la longueur du conduit en ajoutant l équivalent en pied de la figure 2 pour chaque pièce du conduit du système Un exemple est donné à la figure 3 Pour de meilleurs résultats ne pas utiliser plus de trois coudes de 90o S assurer qu il y ait un minimum de 24 po de conduit droit entre les coudes...

Страница 12: ...9 pi 1 3 4 po regardez la distance entre la hotte et la table de cuisson X en FIGURE 4 Cela s accomplit en utilisant plus ou moins du couvercle de la cheminé supérieure La FIGURE 4 illustre les dimensions de chaque pièce du modèle Diamante Isola Pour des installations plus élevées de plafondinclutunestructredesoutènemant additionnelle qui additionne 27 1 2 aux diverses tailled de plafond sur le FI...

Страница 13: ...3 4 po x 24 po min 8 pi 3 4 po max 8 pi 7 3 4 po dimensions d installatioN SANS CONDUIT 121 2 po 4 3 4 po 3 1 2 po à cause de la dimension et du poids de cette hotte le support doit Être fixé fermement au plafond Pour les plafonds en plâtre ou en panneaux muraux secs le support doit être fixé aux solives Si cela est impossible une structure renforcée doit être érigée derrière le plâtre ou les pann...

Страница 14: ... Déterminer et marquer clairement à l aide d un crayon la ligne centrale sur le mur où la hotte sera installée 3 Un gabarit Lde la FIGURE 7 pour installer le support est fourni aveccedernier Utilisercegabarit pourmarquerlestrousdusupport au plafond INSTALLATIONS SANS CONDUIT 1 Le COUVERCLE CHEMINÉE SUPÉRIEURE C de la FIGURE 11 se fixe avec les deux vis fournies G de la FIGURE 11 Si en utilisant Le...

Страница 15: ...ircuit Mettreencircuitleventilateur et la lumière Les interrupteurs de contrôle de la hotte se trouvent à droite sous la hotte Si la hotte ne fonctionne pas vérifiersiledisjoncteurn estpasdéclenchéousilefusiblen est pas grillé Si l appareil ne fonctionne toujours pas débrancher l alimentation et vérifier si les connexions ont été effectuées correctement 5 Connecter le CONNECTEUR DES COMMANDES A de...

Страница 16: ... l acier inoxydable sur les hottes en acier inoxydable Ne pas utiliser de produits abrasifs ou de récurants car ils peuvent égratigner le fini en acier inoxydable et ils ne devraient pas être employés pour nettoyer les surfaces de finition Remplacement de la lumière halogène Avant d essayer de remplacer les ampoules s assurer que l interrupteur soit hors circuit Retirer les deux vis de la FIGURE17...

Страница 17: ... les fusibles de votre maison ou pour corriger votre câblage ou votre système de plomberie 2 Les appels de service pour remplacer ou réparer les ampoules les fusibles ou les filtres de votre hotte de cuisinière 3 Les réparations lorsque votre hotte de cuisinière a été utilisée plus que la normale c est à dire plus que pour une famille par foyer 4 Les dommages résultant d un accident de l altératio...

Отзывы: