Country
UK/IRL
UK/IRL
Category
II
2H3+
II
2H3+
Model type
C11 0f C31
C11 0f C31
Heat input Hi
kW
7.5
7.5
Efficiency class
2
2
NOX class
4
4
Type of gas
G20
G30
Inlet pressure
mbar
20
30/37
Gas rate 15 °C / 1013 mbar
m3/h
800
231
kg/h
540 g
Reference burner pressure
mbar
13
25
Injector size
mm
3x 1.50
3x 0.90
Reduced input restrictor
mm
1.8
1.1
Pilot assembly
Type
SIT 160
SIT 160
Code
Nr 51
Nr 30
Flue system
MV size
100-150
100-150
Preinstalled flue restrictor
mm
30
30
Gas control
GV36 with
GV36 without
pressure reg. pressure reg
Remote control
Voltage adapter
V
4,5
Batteries
2x LR03 1,5 V Alkaline
Gas connection
mm
8 mm nut
8 mm nut
and olive
and olive
Weight incl. packing material
kg
75
75
Dimensions: see table 1
Country
UK/IRL
UK/IRL
Category
II
2H3+
II
2H3+
Model type
C11 0f C31
C11 0f C31
Heat input Hi
kW
7,5
7,5
Efficiency class
2
2
NOX class
4
4
Type of gas
G20
G30
Inlet pressure
mbar
20
30/37
Gas rate 15 °C / 1013 mba
m3/h
790
231
kg/h
540 g
Reference burner pressure
mbar
17
22
Injector size
mm
2x 1,40
3x 1,00
1x 1,30
Reduced input restrictor
mm
1,8
1,1
Pilot assembly
Type
SIT 160
SIT 160
Code
Nr 51
Nr 30
Flue system
MV size
100-150
100-150
Preinstalled flue restrictor
mm
30
30
Gas control
GV36 with
GV36 without
pressure reg.
pressure reg.
Remote control
Voltage adapter
V
4,5
Batteries
2x LR03 1,5 V Alkaline
Gas connection
mm
8 mm nut
8 mm nut
and olive
and olive
Weight incl packing material
kg
75
75
Dimensions: see table 1
UK/IRL
43
UK/IRL
42
8.3 TECHNICAL DATA
MV150 Cadra Nova
8.3 TECHNICAL DATA
MV100 Whisper and Spectra Nova