background image

UK/IRL

 19

UK/IRL

 18

4.2 Preparing the appliances Widescreen and Whisper (continuing)

4. Take the box with the log set out of the combustion chamber.

5. Place the right flue restrictor in the combustion chamber. To

determine the right flue restrictor, see chapter 3. 

C

C

C

C

C

C

C

C

C

C

fig. 8

fig. 9

4.2 Preparing the appliances Widescreen and Whisper (continuing)

2.

Remove the back panel by loosening the screws B (see fig. 6). 

3. Remove the glass by removing the glass clamps C (see fig. 7) for

instance with a screwdriver. Careful when removing the glass! Wear

gloves! Before placing the glass back, be sure that there are no

fingerprints on the glass, it is not possible to remove those prints

after you burn the appliance or a while (they will be burnt in).

A

A

A

B

B

B

B

B

fig. 6

fig. 7

Содержание CADRA NOVA

Страница 1: ...al room sealed built in gas fireplace 40 010 527 02 37 SILENCE FEELING WHISPER SPECTRA NOVA CADRA NOVA MISTY Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 Log Burner Technology ...

Страница 2: ... Connection of the flue 27 5 2 Placing through existing chimney 28 5 3 Remote control 30 6 COMMISIONING 32 6 1 Check pilot ignition 32 6 2 Functional burner check 32 6 3 Functional balanced flue check 33 6 2 Check reference pressure 33 7 HANDING OVER 34 8 SERVICING 35 8 1 Routine annual servicing 35 USER GUIDE 45 9 SAFETY INSTRUCTIONS FOR THE USER 46 10 CONTROLING THE APPLIANCE 48 11 CLEANING AND ...

Страница 3: ...stribution conditions identification of the type of gas and pressure and the adjustment of the appliance are compatible This gas appliance is factory set and shall not be adjusted by the installer This appliance does not contain any component manufactured from asbestos or any asbestos related products The pilot and flame sensing device fitted to this fire is also a safety device If for any reason ...

Страница 4: ... producing appliances soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured This should be born in mind when installing the appliance 3 1 Builders opening and surround The appliance can be installed in the following situations In a non combustible fireplace or builders opening This could be either an existing builders opening or a new ma...

Страница 5: ...d out of non combustible composition board Fibrelux and you install the appliance without a mantel then Ventilate the space above the appliance min 1000 mm2 Always fit the DC convection set The plaster of the outside has to be resistant to a high temperature Use therefore the plaster materials especially made for this to prevent discoloring min 100 C temperature resistant If the appliance is to be...

Страница 6: ...al position if the desired situation is possible To establish this you will need to calculate The effective height this is the real difference in height between the upper side of the appliance and the terminal The total horizontal extension This is the total horizontal flue length where each elbow which is in the horizontal area counts for 2 meters each 45 degree bend which is in the horizontal ar...

Страница 7: ...ed 0 remove flue restrictor Horizontal extension Effective height Number is size in mm of the flue restrictor table 2 interior Widescreen table 3 interior MV100 UK IRL 10 fig 2a Hvert N M L K J I H fig 2b Hvert A F G E D C B Example calculation 1 Calculati0n horizontal extension fig 2a Flue lenght C E 1m 1m 2 m Elbows D 2m 2 m Total horizontal extension 4 m Measure or calculate effective height Hv...

Страница 8: ...st 0 5 meters of the sides of the roof excluded the ridge UK IRL 12 Table Cadra Nova with interior MV150 Determine according to the table 4 the right total horizontal and vertical length When meeting an X and when the values are outside the table the combination is not allowed Normally the 30 mm flue restrictor is preinstalled Misty with roundscreen Determine according to the table 5 the right tot...

Страница 9: ...es 500 mm F Below balconies or car port roof 600 mm G From a vertical drain pipe or soil pipe 300 mm H From an internal or external corner 600 mm I Above ground roof or balcony level 300 mm J From a surface facing the terminal 600 mm K From a terminal facing the terminal 600 mm L From an opening in the carport e g 1200 mm window into the dwelling M Vertically from a terminal on the same wall 1500 ...

Страница 10: ...ind the door see fig 5 Lift and pull forward when you take it away A C B gas supply routes when fire is fitted in a deep surround C Through wall Pipe must be sleeved and sealed to fire A B Behind surround Sleeve pipe through surround inner wall outer wall cavity surround marble Example of how terminal position is measured 3 2 2 Using an existing chimney as air inlet You can connect the appliance o...

Страница 11: ...g 8 fig 9 4 2 Preparing the appliances Widescreen and Whisper continuing 2 Remove the back panel by loosening the screws B see fig 6 3 Remove the glass by removing the glass clamps C see fig 7 for instance with a screwdriver Careful when removing the glass Wear gloves Before placing the glass back be sure that there are no fingerprints on the glass it is not possible to remove those prints after y...

Страница 12: ...paring the appliance Misty 1 Remove the door frame Lift and pull forward see fig 10 2 Open the ashtray door by pulling down bottom handle 3 To open the door remove the screws C see fig 11 The door opening is limited if you need more space then remove the door lift and pull forward Be sure that there are no fingerprints on the glass It is not possible to remove those prints after you burn the appli...

Страница 13: ... right flue restrictor see chapter 3 fig 15 4 4 Preparing the appliances Spectra Nova Cadra Nova 1 To open the door remove the screws A see fig 13 Open and remove the door lift and pull forward Be sure that there are no fingerprints on the glass It is not possible to remove those prints after you burn the appliance for a while they are burnt in 2 Remove the back panel by loosening the 4 screws B s...

Страница 14: ... frame first ceramic blanket ceramic blanket ceramic blanket ceramic blanket ceramic blanket 4 5 Fitting the firebox Points of attention for placement If possible first locate the appliance before assembling the flue If this is not possible then always use an extendible pipe before connection onto the appliance 1 Position the firebox in the fireplace opening You can adjust the height with the 4 ad...

Страница 15: ...r roof mounted terminal To obtain a smoke sealed connection the inner pipe must be 20 mm longer then the outside pipe The horizontal pipes need to rise away from the appliance at a rate of 3 degrees per metre UK IRL 26 4 6 Placing the log set Never place extra elements of any kind into the combustion chamber To guarantee good combustion the log set may only be installed in the way specified by Fab...

Страница 16: ... chimney The existing chimney then functions as air supply where a flexible stainless steel liner to BS715 of 100 mm performs the flue function Any existing chimney used as an air supply must only service this appliance Requirements 300 mm of free space above the appliance The chimney only supply s air to this appliance The existing chimney needs to be clean and very well swept The existing chimne...

Страница 17: ...trol now functions 6 Check if you can hear a sound and the motor runs when you push a button on the remote control fig 22 UK IRL UK IRL 5 3 Remote control if applicable The remote control is only meant to regulate the flames it functions only when the pilot burner is ignited It is therefore not possible to ignited the appliance with the remote control or to shut off the pilot flame The radio frequ...

Страница 18: ...ight the appliance Turn to max input and test around the test point D for gas soundness using a suitable leak detection fluid C D D C A B B A fig 24 UK IRL UK IRL 6 COMMISSIONING functional checks 6 1 Check pilot ignition 1 Push in and turn the control knob A from anticlockwise to the setting small flame You will hear a tick meaning there is ignition Hold the knob in and wait for a few seconds whi...

Страница 19: ...the log lay and replace the embers if applicable 3 Do the functional test as described at page 34 4 Check the flue system and terminal on damage and soundness visual inspection UK IRL UK IRL 7 HANDING OVER final check and customer briefing 7 1 Instruct the customer on the full operation of the appliance 7 2 1 Advise the customer how to clean the appliance including the glass 7 2 2 Instruct the cus...

Страница 20: ...glass with clean hands wear gloves if possible 3 To fit the glass proceed in reverse order Make sure that the log set has been installed correctly before fixing the glass Attention Before placing the glass check the glass sealing rope is in good condition and makes an effective seal Be sure that there are no fingerprints on the glass It is not possible to remove those prints after you burn the app...

Страница 21: ...ioned in the flue outlet A Ratio of CO CO2 should be less than 0 01 within 30 minutes 100ppm CO per 1 CO2 A reading of CO in the room centre should give a rise of less than 9ppm over ambient peak reading 8 1 6 Gas control block A Governor B Adjusting screw pilot flame C Inlet pressure test point D Burner pressure test point C D D C A B B A fig 26 ...

Страница 22: ...54 20900154 20900154 20900154 20900154 Thermocouple 37002033 37002033 37002033 37002033 37002033 37002033 Spark electrode 06006600 06006600 06006600 06006600 06006600 06006600 Embers 20900019 20900019 20900019 20900019 20900019 20900019 Heat resisting paint spray for comb chamb 09000008 09000008 09000008 09000008 09000008 09000008 Set of glass clips 20900008 20900008 20900008 x x x Touch Latch ass...

Страница 23: ...ing material kg 75 75 Dimensions see table 1 Country UK IRL UK IRL Category II2H3 II2H3 Model type C11 0f C31 C11 0f C31 Heat input Hi kW 7 5 7 5 Efficiency class 2 2 NOX class 4 4 Type of gas G20 G30 Inlet pressure mbar 20 30 37 Gas rate 15 C 1013 mba m3 h 790 231 kg h 540 g Reference burner pressure mbar 17 22 Injector size mm 2x 1 40 3x 1 00 1x 1 30 Reduced input restrictor mm 1 8 1 1 Pilot ass...

Страница 24: ...e 15 C 1013 mbar m3 h 900 231 kg h 540 g Reference burner pressure mbar 16 25 Injector size mm 3x 1 50 3x 0 95 Reduced input restrictor mm 1 8 1 1 Pilot assembly Type SIT 160 SIT 160 Code Nr 51 Nr 30 Flue system MV size 100 150 100 150 Preinstalled flue restrictor mm 30 30 Gas control GV36 with GV36 without pressure reg pressure reg Remote control Voltage adapter V 4 5 Batteries 2x LR03 1 5 V Alka...

Страница 25: ...NS FOR THE USER 9 1 General safety instructions If a gas leak is found or suspected turn off the gas supply at the meter and contact your installer or gas emergency service These instructions should be read carefully and retained for future reference Do not use the fire with a broken or damaged glass The fire has a safety device which turns off the gas supply if there is a build up from flue gasse...

Страница 26: ...ited by the pilot flame Once ignition has taken place the fire may be set to any level between min and max by adjusting the control knob B 10 2 To light 1 Push in and turn the control knob A from anticlockwise to the setting small flame You will hear a ignition click Check that the pilot is lit if not repeat 2 Continue to hold in the control knob for a further ten seconds to ensure that the pilot ...

Страница 27: ...wise to position 2 To disable knob B turn knob A to the position 3 To extinguish the pilot turn control knob A to position although it is in order lo leave the pilot permanently lit 10 3 1 When the pilot extinguishes Warning When the pilot extinguishes for whatever reason you should wait at least 5 minutes before trying to turn it on again Possible causes of pilot extinguish are Operating error In...

Страница 28: ...ontrol The remote control now functions 7 Check if you can hear a sound and the motor runs when you push a button on the remote control 10 4 4 Changing the batteries There is no risk of electric shock as the low voltage supply is similar to that used in torches Always turn off the appliance before changing batteries Remote control 1 Remove the cover on the back of the remote control 2 Carefully re...

Страница 29: ...d of responsibly and in conformity with government regulations Remove the batteries before disposing of the remote control Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities 11 CLEANING AND SERVICE INSTRUCTIONS Important Turn off the fire and allow it to cool down before commencing cleaning It is recommended that the fire is inspected servi...