background image

Installation

 

Instructions

 

 

6 < 

<

 

<

 

<

 

1

 

Dear

 

user

 

Congratulations

 

on

 

purchasing

 

your

 

Faber

 

product!

 

A

 

quality

 

product,

 

which

 

provide

 

you

 

with

 

the

 

warmth

 

and

 

atmosphere

 

for

 

many

 

years.

 

Please

 

read

 

the

 

user

 

manual

 

before

 

using

 

the

 

fire.

 

Should,

 

despite

 

the

 

careful

 

final

 

checks,

 

a

 

malfunction

 

occur,

 

please

 

contact

 

your

 

Faber

 

dealer.

  

 

 

Please

 

note:

  

The

 

data

 

of

 

your

 

fire

 

is

 

available

 

in

 

the

 

user

 

manual.

 

1.1

 

Introduction

 

Only

 

have

 

the

 

appliance

 

installed

 

by

 

a

 

qualified

 

installer

 

according

 

to

 

the

 

gas

 

safety

 

regulations.

 

Read

 

this

 

installation

 

manual

 

properly.

 

1.2

 

Please

 

check

 

Check

 

the

 

fire

 

for

 

transport

 

damage

 

and

 

report

 

any

 

damage

 

immediately

 

to

 

your

 

dealer.

  

1.3

 

CE

 

Declaration

 

Glen

 

Dimplex

 

Benelux

 

certifies

 

that

 

this

 

Faber

 

fire

 

complies

 

with

 

the

 

essential

 

requirements

 

of

 

the

 

gas

 

appliances

 

directive.

 

Product:

 

gas

 

room

 

heater

 

Model:

 

Relaxed

 

Premium

 

L

  

Applicable

 

EC

 

directives:

 

90/396/EEC

 

Harmonised

 

standards

 

applied:

 

NEN

EN

613

 

NEN

EN

613/A1

 

 

This

 

Declaration

 

is

 

invalid,

 

if

 

without

 

the

 

written

 

permission

 

of

 

Glen

 

Dimplex

 

Benelux:

 

 

Changes

 

are

 

made

 

to

 

the

 

appliance.

 

 

The

 

fire

 

is

 

connected

 

to

 

other

 

exhaust

 

materials

 

than

 

specified.

 

2

 

Safety

 

instructions

 

 

The

 

unit

 

must

 

be

 

installed

 

and

 

checked

 

every

 

year

 

according

 

to

 

these

 

instructions

 

and

 

the

 

applicable

 

national

 

and

 

local

 

regulations.

 

 

Ensure

 

that

 

the

 

data

 

on

 

the

 

type

 

label

 

matches

 

the

 

local

 

gas

 

type

 

and

 

pressure.

 

 

The

 

settings

 

and

 

the

 

construction

 

of

 

the

 

fire

 

must

 

not

 

be

 

changed!

 

 

Do

 

not

 

place

 

extra

 

imitation

 

wood

 

or

 

other

 

smouldering

 

material

 

on

 

the

 

burner

 

or

 

in

 

the

 

combustion

 

chamber.

  

 

The

 

unit

 

is

 

for

 

atmosphere

 

and

 

heating

 

purposes.

 

This

 

means

 

that

 

all

 

surfaces,

 

including

 

the

 

glass,

 

can

 

be

 

very

 

hot

 

(over

 

100°C);

 

exceptions

 

to

 

this

 

are

 

the

 

bottom

 

of

 

the

 

fire

 

and

 

the

 

control

 

elements.

 

 

Do

 

not

 

place

 

any

 

combustible

 

materials

 

within

 

0.5

 

m

 

of

 

the

 

radiation

 

area

 

of

 

the

 

fire.

  

 

Light

 

the

 

fire

 

for

 

the

 

first

 

time

 

and

 

run

 

for

 

several

 

hours

 

on

 

the

 

highest

 

setting,

 

so

 

that

 

the

 

paint

 

can

 

cure.

 

Provide

 

adequate

 

ventilation,

 

so

 

that

 

any

 

fumes

 

can

 

disperse

 

;

 

we

 

recommend

 

vacating

 

the

 

room

 

during

 

this

 

process

 

 

 

Please

 

note

  

Through

 

the

 

natural

 

air

 

circulation

 

of

 

the

 

fire

 

moisture

 

and

 

uncured

 

volatile

 

components

 

from

 

paint,

 

building

 

materials

 

and

 

carpeted

 

floors,

 

etc.

 

are

 

attracted.

 

These

 

parts

 

can

 

settle

 

as

 

soot

 

on

 

cold

 

surfaces.

 

Therefore

 

do

 

not

 

light

 

the

 

fire

 

shortly

 

after

 

installation.

 

3

 

Installation

 

requirements

 

3.1

 

Fire

 

 

This

 

device

 

can

 

be

 

built

 

into

 

an

 

existing

 

or

 

new

 

chimney.

 

 

For

 

devices

 

with

 

flexible

 

gas

 

pipes

 

the

 

gas

 

regulator

 

block

 

is

 

mounted

 

on

 

the

 

right

 

side

 

of

 

the

 

fire

 

for

 

transport

 

reason.

 

 

The

 

gas

 

regulator

 

block

 

with

 

the

 

receiver

 

and

 

the

 

I.T.C.

 

must

 

be

 

placed

 

directly

 

behind

 

a

 

service

 

door.

 

(see

 

Fig.

 

3.1)

  

3.2

 

False

 

chimney

 

breast

 

or

 

other

 

structure

   

 

The

 

False

 

chimney

 

should

 

be

 

of

 

non

combustible

 

material.

 

 

The

 

space

 

above

 

the

 

fire

 

should

 

always

 

be

 

ventilated

 

using

 

the

 

supplied

 

grids

 

or

 

a

 

similar

 

alternative

 

with

 

minimal

 

free

 

passage

 

of

 

200cm²

 

per

 

grid.

  

3.3

 

Fluepipe

 

and

 

terminal

 

requirements

 

 

For

 

the

 

supply

 

of

 

the

 

combustion

 

air

 

and

 

the

 

discharge

 

of

 

the

 

combustion

 

gases

 

you

 

should

 

always

 

use

 

the

 

Flue

 

materials

 

specified

 

by

 

Faber

.

 

 

 

Please

 

note:

 

 

Only

 

when

 

using

 

these

 

materials

 

can

 

Faber

 

guarantee

 

the

 

safe

 

and

 

proper

 

operation

 

of

 

the

 

appliance.

 

 

The

 

outside

 

of

 

the

 

concentric

 

flue

 

material

 

can

 

heat

 

up

 

to

 

+/

150°C.

 

Ensure,

 

when

 

penetrating

 

a

 

flammable

 

wall

 

or

 

ceiling,

 

Содержание 40010959-1440

Страница 1: ...Relaxed Premium M 40010959 1440 Relaxed Premium M ENG ...

Страница 2: ...Installation Instructions 1 3 alternative finishes 1 1a 1 1b 1 1c ...

Страница 3: ...Installation Instructions 2 1 2 1 3 1 4 7 ...

Страница 4: ...Installation Instructions 3 1 9 1 5 1 6 B ...

Страница 5: ...Installation Instructions 4 2 1 2 2 2 3 3 1 3 2 3 3 3 4 ...

Страница 6: ...Installation Instructions 5 3 5 4 1 4 2 4 3 ...

Страница 7: ...e and heating purposes This means that all surfaces including the glass can be very hot over 100 C exceptions to this are the bottom of the fire and the control elements Do not place any combustible materials within 0 5 m of the radiation area of the fire Light the fire for the first time and run for several hours on the highest setting so that the paint can cure Provide adequate ventilation so th...

Страница 8: ...30mm with CE marking for 600 C Please note The minimum chimney diameter for a 130mm flexible stainless steel pipe must 200 x 200mm And for a 100mm flexible stainless steel pipe 150x150mm 4 Preparation and installation instructions 4 1 Gas connection The gas connection must comply with the applicable local standards We advise using a Ø 15mm gas connection directly from the gas meter to the applianc...

Страница 9: ...ngs Fig 1 2 C Spacer Fig 1 2 D F and H Fig 1 3 Please note Ensure that the fire is not load bearing with regard to the false chimney breast See the dimensional drawing Chapter 18 1 Pay special attention to the following points 1 Check during work if the glass can be inserted and removed 2 Check during work if the mouldings B Fig 1 2 or Q Fig 1 5 match 4 6 4 Method 1 Fig 1 1a Build the false chimne...

Страница 10: ...e ignition of the main burner on full and small setting ignition must be smooth and quiet 7 2 Checking for gas leaks Check with a gas leak finder or spray all connections and pipes for gas leakage 7 3 Checking the burner pressure and primary pressure Check that the burner pressure and primary pressure match the information listed in the manual Chapter 14 Technical specifications Measuring the prim...

Страница 11: ...mber o The glass o The logs for breakage o The outlet Replace if necessary o Chips Embers Glow wire 9 2 Cleaning the glass Most deposits can be removed with a dry cloth Clean the glass with a ceramic hob cleaner Please note Avoid fingerprints on the glass These are no longer removable after they are burnt in Now carry out check up as described in Chapter 7 Checking after installation 10 Conversion...

Страница 12: ...zontal bends are bends which are entirely in the horizontal plane Bends Elbows 90 vertical to horizontal plane These are 90 elbows which proceed from horizontal to vertical Fig 12 2 and 12 3 G O and S Bends 45 or 30 vertical to horizontal plane These are 30 or 45 bends with a vertical offset of less than 45 Fig 12 1 B and D Pipes under a tilt angle These are pipes which are vertically ascending at...

Страница 13: ...50 50 50 40 40 30 x x x x 10 60 60 50 50 50 40 30 x x x x 11 60 60 60 50 50 40 30 x x x x 12 65 60 60 50 50 40 30 x x x x 13 65 60 60 50 50 40 30 x x x x 14 65 60 60 50 50 40 30 x x x x 15 65 60 60 50 50 40 30 x x x x 16 65 60 60 50 50 40 30 x x x x 17 65 60 60 50 50 40 30 x x x x 18 65 60 60 50 50 40 30 x x x x 19 65 60 60 50 50 40 30 x x x x 20 65 60 60 50 50 40 30 x x x x 21 65 60 60 50 50 40 3...

Страница 14: ...Installation Instructions 13 12 Example Fig 12 1 Fig 12 2 Fig 12 3 ...

Страница 15: ...Installation Instructions 14 13 Calculation Sheet ...

Страница 16: ...Installation Instructions 15 ...

Страница 17: ...h 0 932 0 956 0 836 0 253 0 253 At 15 C and 1013 mbar gr h 480 480 Burner pressure at full load mbar 16 16 11 25 25 Nozzle main burner mm Middle 390 Side 360 Middle 390 Side 360 Middle 390 Side 360 ST 1 04 ST 1 04 Low flow rate mm 1 8 1 8 1 8 1 3 1 3 Pilot light SIT145 SIT145 SIT145 SIT145 SIT145 Nozzle code No 36 No 36 No 36 No 23 No 23 Diameter exhaust supply mm 130 200 130 200 130 200 130 200 1...

Страница 18: ... Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof termina...

Страница 19: ...Installation Instructions 18 16 Dimensional drawings 16 1 Relaxed Premium M 834 Ext Build in opening 348 Ext 460 max 110 min ...

Страница 20: ...Installation Instructions 19 16 2 Ventilation grid and control door ...

Страница 21: ...Installation Instructions 20 ...

Страница 22: ...Installation Instructions 21 ...

Страница 23: ...Installation Instructions 22 ...

Страница 24: ...Dealer info ...

Отзывы: