Installation

 

Instructions

 

 

11 < 

<

 

<

 

<

 

 

Total

 

Vertical

 

Height

 

(TVH)

 

TVH

 

is

 

the

 

difference

 

in

 

height

 

measured

 

from

 

the

 

top

 

of

 

the

 

unit

 

to

 

the

 

outlet;

 

it

 

can

 

be

 

measured

 

or

 

determined

 

from

 

the

 

building

 

plan.

 

For

 

clarification

 

see

 

the

 

TVH

 

indication

 

in

 

the

 

drawings.

 

(Fig.

 

12.1,

 

12.2

 

and

 

12.3:

 

TVH)

 

 

Total

 

Horizontal

 

Length

 

(THL)

 

THL

 

is

 

the

 

Total

 

Horizontal

 

Length

 

and

 

consists

 

of

 

elbows

 

and

 

pipes

 

which

 

are

 

entirely

 

in

 

the

 

horizontal

 

plane.

 

Elbows

 

I,

 

K

 

and

 

Q

 

and

 

the

 

elements

 

H,

 

J,

 

L,

 

M,

 

P

 

and

 

R

 

(Fig.

 

12.1

 

and

 

12.2).

 

 

Horizontal

 

length

 

The

 

horizontal

 

length

 

consists

 

of

 

the

 

elements

 

H,

 

J,

 

L,

 

M,

 

P

 

and

 

R

 

(Fig.

 

12.1

 

end

 

12.2).

 

 

Elbows

 

90°

 

in

 

the

 

horizontal

 

plane

 

Horizontal

 

bends

 

are

 

bends

 

which

 

are

 

entirely

 

in

 

the

 

horizontal

 

plane

 

(Fig.

 

12.1,

 

12.2

 

and

 

12.3

 

I,

 

K

 

and

 

Q).

 

 

Bends

 

45°

 

or

 

30°

 

in

 

the

 

horizontal

 

plane

 

Horizontal

 

bends

 

are

 

bends

 

which

 

are

 

entirely

 

in

 

the

 

horizontal

 

plane

 

 

Bends

 

Elbows

 

90°

 

vertical

 

to

 

horizontal

 

plane

  

These

 

are

 

90°

 

elbows,

 

which

 

proceed

 

from

 

horizontal

 

to

 

vertical

 

(Fig.

 

12.2

 

and

 

12.3

 

G,

 

O

 

and

 

S)

 

 

Bends

 

45°

 

or

 

30

 

°vertical

 

to

 

horizontal

 

plane

 

These

 

are

 

30°

 

or

 

45°

 

bends

 

with

 

a

 

vertical

 

offset

 

of

 

less

 

than

 

45°

 

(Fig.12.1

 

B

 

and

 

D).

 

 

Pipes

 

under

 

a

 

tilt

 

angle:

 

These

 

are

 

pipes

 

which

 

are

 

vertically

 

ascending

 

at

 

an

 

angle

 

of

 

30°

 

or

 

45°.

 

(Fig.

 

12.1

 

C).

 

Fill

 

in

 

only

 

in

 

combination

 

with

 

at

 

least

 

2

 

x

 

30

 

or

 

45°

 

bends

 

in

 

the

 

vertical

 

part.

 

 

Table:

 

See

 

the

 

table

 

at

 

the

 

right

 

vertical

 

(TVH)

 

and

 

horizontal

 

length

 

(THL).

 

 

For

 

“x”

 

and

 

if

 

the

 

values

 

are

 

outside

 

the

 

table,

 

then

 

the

 

combination

 

is

 

not

 

allowed.

 

Only

 

then

 

adjust

 

the

 

TVH

 

or

 

THL.

 

If

 

a

 

value

 

is

 

indicated,

 

check

 

that

 

the

 

calculated

 

STL

 

value

 

is

 

not

 

lower

 

than

 

indicated

 

in

 

the

 

table.

 

In

 

this

 

case

 

STL

 

must

 

be

 

adjusted.

  

The

 

found

 

value

 

indicates

 

the

 

width

 

of

 

the

 

restrictor

 

(“0”

 

means

 

no

 

restrictor).

 

Standard

 

is

 

a

 

restrictor

 

of

 

30mm

 

installed.

 

(Fig.

 

3.4).

 

 
 

Содержание 40010959-1440

Страница 1: ...Relaxed Premium M 40010959 1440 Relaxed Premium M ENG ...

Страница 2: ...Installation Instructions 1 3 alternative finishes 1 1a 1 1b 1 1c ...

Страница 3: ...Installation Instructions 2 1 2 1 3 1 4 7 ...

Страница 4: ...Installation Instructions 3 1 9 1 5 1 6 B ...

Страница 5: ...Installation Instructions 4 2 1 2 2 2 3 3 1 3 2 3 3 3 4 ...

Страница 6: ...Installation Instructions 5 3 5 4 1 4 2 4 3 ...

Страница 7: ...e and heating purposes This means that all surfaces including the glass can be very hot over 100 C exceptions to this are the bottom of the fire and the control elements Do not place any combustible materials within 0 5 m of the radiation area of the fire Light the fire for the first time and run for several hours on the highest setting so that the paint can cure Provide adequate ventilation so th...

Страница 8: ...30mm with CE marking for 600 C Please note The minimum chimney diameter for a 130mm flexible stainless steel pipe must 200 x 200mm And for a 100mm flexible stainless steel pipe 150x150mm 4 Preparation and installation instructions 4 1 Gas connection The gas connection must comply with the applicable local standards We advise using a Ø 15mm gas connection directly from the gas meter to the applianc...

Страница 9: ...ngs Fig 1 2 C Spacer Fig 1 2 D F and H Fig 1 3 Please note Ensure that the fire is not load bearing with regard to the false chimney breast See the dimensional drawing Chapter 18 1 Pay special attention to the following points 1 Check during work if the glass can be inserted and removed 2 Check during work if the mouldings B Fig 1 2 or Q Fig 1 5 match 4 6 4 Method 1 Fig 1 1a Build the false chimne...

Страница 10: ...e ignition of the main burner on full and small setting ignition must be smooth and quiet 7 2 Checking for gas leaks Check with a gas leak finder or spray all connections and pipes for gas leakage 7 3 Checking the burner pressure and primary pressure Check that the burner pressure and primary pressure match the information listed in the manual Chapter 14 Technical specifications Measuring the prim...

Страница 11: ...mber o The glass o The logs for breakage o The outlet Replace if necessary o Chips Embers Glow wire 9 2 Cleaning the glass Most deposits can be removed with a dry cloth Clean the glass with a ceramic hob cleaner Please note Avoid fingerprints on the glass These are no longer removable after they are burnt in Now carry out check up as described in Chapter 7 Checking after installation 10 Conversion...

Страница 12: ...zontal bends are bends which are entirely in the horizontal plane Bends Elbows 90 vertical to horizontal plane These are 90 elbows which proceed from horizontal to vertical Fig 12 2 and 12 3 G O and S Bends 45 or 30 vertical to horizontal plane These are 30 or 45 bends with a vertical offset of less than 45 Fig 12 1 B and D Pipes under a tilt angle These are pipes which are vertically ascending at...

Страница 13: ...50 50 50 40 40 30 x x x x 10 60 60 50 50 50 40 30 x x x x 11 60 60 60 50 50 40 30 x x x x 12 65 60 60 50 50 40 30 x x x x 13 65 60 60 50 50 40 30 x x x x 14 65 60 60 50 50 40 30 x x x x 15 65 60 60 50 50 40 30 x x x x 16 65 60 60 50 50 40 30 x x x x 17 65 60 60 50 50 40 30 x x x x 18 65 60 60 50 50 40 30 x x x x 19 65 60 60 50 50 40 30 x x x x 20 65 60 60 50 50 40 30 x x x x 21 65 60 60 50 50 40 3...

Страница 14: ...Installation Instructions 13 12 Example Fig 12 1 Fig 12 2 Fig 12 3 ...

Страница 15: ...Installation Instructions 14 13 Calculation Sheet ...

Страница 16: ...Installation Instructions 15 ...

Страница 17: ...h 0 932 0 956 0 836 0 253 0 253 At 15 C and 1013 mbar gr h 480 480 Burner pressure at full load mbar 16 16 11 25 25 Nozzle main burner mm Middle 390 Side 360 Middle 390 Side 360 Middle 390 Side 360 ST 1 04 ST 1 04 Low flow rate mm 1 8 1 8 1 8 1 3 1 3 Pilot light SIT145 SIT145 SIT145 SIT145 SIT145 Nozzle code No 36 No 36 No 36 No 23 No 23 Diameter exhaust supply mm 130 200 130 200 130 200 130 200 1...

Страница 18: ... Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof termina...

Страница 19: ...Installation Instructions 18 16 Dimensional drawings 16 1 Relaxed Premium M 834 Ext Build in opening 348 Ext 460 max 110 min ...

Страница 20: ...Installation Instructions 19 16 2 Ventilation grid and control door ...

Страница 21: ...Installation Instructions 20 ...

Страница 22: ...Installation Instructions 21 ...

Страница 23: ...Installation Instructions 22 ...

Страница 24: ...Dealer info ...

Отзывы: