Troubleshooting
No AC Output but Weld Output
If the welder section functions properly but you have no AC output remove the
receptacle panel and make sure the white plugs are plugged solid. If there are
connected all the way, disconnect and make a resistance reading as follows
Blue to Brown (1.2ohm)
Black to White (1.2ohms)
If either one of those two readings are open the AC windings are defective. If they both
check out ok, check the receptacle and the wires going to the receptacles. To be certain
that is in the receptacle panel wiring, very carefully startup the welder and check for
120 volts between Blue and Brown and again 120 Volts between Black and White. If
you have 120 Volts pressing at those two readings, you must have a defective receptacle
or receptacle wiring.