FAAC XTR B Скачать руководство пользователя страница 19

XTR B 

11 

3FW#

3

4

5

1

2

> 5  s

- MASTER

- SLAVE

4

6

z

z

 

< 5  s

®

2 (

¿

)  , 

z

® ®

®

®

 ~ 

5 s

8. ADDING TAGS

This procedure allows additional Tags to be enabled 

subsequently to the first storage procedure. 

You must have a Master Tag that has already been 

stored and be close to the reader (without having to 

open it).  If the XTR B is connected to a BUS-RELAY 

interface, use a Master Tag of the required Group.

Tags can be added as either Master or Slave tags.

L

Slave tags cannot be used to enable the 

addition of Tags.

ADDING MASTER TAGS

 

The XTR B must be in standby.

1. 

Bring a Tag that has NOT been stored up to the 

reader and wait for about 5 s:

 

-

The XTR B will beep twice and flash twice, then 

the LEDs will come on steadily.

2. 

Move the Tag away.

3. 

Bring the previously stored Master Tag up to the 

reader within 10 s.

 

-

The LEDs still remain steady, the XTR B will

BEEP once.

4. 

Move the Master Tag away within 5 s.

 

-

It will flash for 10 s (storing enabled).

5. 

Bring the Tags to add up to the reader in se-

quence, within 10 s of each other.  The XTR B 

beeps once and the LEDs turn on for 1 s for each 

Tag added.

6. 

To finish, let 10 s pass without bringing a new 

Tag up to the reader.

 

-

The LEDs turn off: XTR B in standby.

ADDING SLAVE TAGS

 

Follow the previous procedure but at step 

4

, wait 

until the XTR B beeps twice before moving the 

Master Tag away.

9. MAINTENANCE

Clean the outer surfaces only with a soft cloth Do not 

use detergents or oils.

ADDING TAGS

Master  Tag  already 

stored

Tag NOT stored

Tag to add

 

timeout without Tag: 

{

  END

...  10  s   (

 

timeout)

...  

¿

 10 s  MAX

¿

10 s  (

 

timeout)

 + 

z

 1 s:  Tag OK  , 

¿

 10 s 

 

timeout

Содержание XTR B

Страница 1: ...XTR B EN...

Страница 2: ...XTR B 2 3FW...

Страница 3: ...Leer las instrucciones C Eliminar seg n las directivas vigentes D Referencia Notified Body E Lugar de fabricaci n F Frecuencia Identificatielabelproduct A Identificatiecode van het model B De instruc...

Страница 4: ...mm 15 mm XTR B INOX XTR B GuarnizioneditenutaIP IPsealinggasket Jointd tanch it IP IPDichtung Junta de estanqueidad IP IP afdichting GuarnizioneditenutaIP IPsealinggasket Jointd tanch it IP IPDichtun...

Страница 5: ...asy Morsetti BUS 2easy Terminals BUS 2easy bornes BUS 2easy Klemmen BUS2easyBornes BUS2easyAansluitklemmen BZ1 Buzzer Buzzer Buzzer Buzzer Zumbador Buzzer DL2DL3 Led LED Led LED Led Led 0 5mm2 Sezione...

Страница 6: ...Guarnizione di tenuta IP IP sealing gasket Joint d tanc h it IP IP Dichtung Junta de estanqueidad IP IP afdichting Guarnizione di tenuta IP IP sealing gasket Joint d tanc h it IP IP Dichtung Junta de...

Страница 7: ...XTR B 05 3FW 4 5 5 click click XTR B INOX XTR B...

Страница 8: ...XTR B 06 3FW 6 SW1 BZ1 J7 J5 SW2 ON 1 2 3 4 5 SW1 BZ1 SW1 BZ1 J7 J5 SW2 ON 1 2 3 4 5 SW1 BZ1 XTRB A XTRB B A B A B A B...

Страница 9: ...Maintained action command 1 10 Maintained action command 2 10 8 ADDING TAGS 11 9 MAINTENANCE 11 EN Translation of the original instructions CEDECLARATIONOFCONFORMITY The Manufacturer Companyname FAAC...

Страница 10: ...The range also includes for example the XK10 XK11 and XKP B see catalogue The XTR B only recognises dedicated FAACTags see catalogue A limited number of Tags can be ena bled EachTagcanbeusedforanimpul...

Страница 11: ...ices that are alreadyinstalledinordertoidentifywhichcommandsarealreadyused Forfuturereference you canmakeanoteofthecommandsofalltheinstalleddevicesinthetableattheendofthismanual The configuration of B...

Страница 12: ...s storing enabled 3 Repeat step 2for furtherTags 4 To finish let 10 s pass without bringing any new Tags up to the reader or press the button immediately The LEDs turn off XTR B in standby Errorsduri...

Страница 13: ...4 irrelevant Each control device connected to the BUS RELAY interface must have a different ID LInordertoaddanXTRBtoanexistingsystemyoumustknowtheIDsoftheotherBUS2easydevices that are present See the...

Страница 14: ...enabled 4 To finish let 10 s pass without bringing any new Tags up to the reader or press the button immediately The LEDs turn off XTR B in standby Repeat the procedure to enable another Group At step...

Страница 15: ...ll theTags of the Group The procedure is only active if the XTRBisconnectedtoaBUS RELAYinterface Inothercases carryoutthe TotalDeletion procedure The XTR B must be in standby 1 Select the Group to del...

Страница 16: ...0s bringupaMasterTagalreadystored on the previous XTR B The XTR B will beep and flash the same number oftimesasthenumberoftheGroupandtheLEDs will come on for 2 s then flashing resumes 4 Press the butt...

Страница 17: ...adily 2 Move the Tag away when you wish to stop the command the LEDs turn off IMPULSECOMMAND2 1 With the XTR B in standby bring the Tag close to the reader and hold it there the XTR B beeps once and t...

Страница 18: ...away when you wish to stop the command the LEDs turn off MAINTAINEDACTIONCOMMAND2 1 With the XTR B in standby bring the Tag close to the reader and hold it there the XTR B beeps once and the LEDs will...

Страница 19: ...come on steadily 2 Move theTag away 3 Bring the previously stored MasterTag up to the reader within 10 s The LEDs still remain steady the XTR B will BEEP once 4 Move the MasterTag away within 5 s It...

Страница 20: ...XTR B 12 3FW Dispositivo Device Dispositif Vorrichtung Dispositivo Inrichting 1 Comando Command Commande Steuerung Comando Commando 2 Comando Command Commande Steuerung Comando Commando ID...

Страница 21: ...XTR B 13 3FW Dispositivo Device Dispositif Vorrichtung Dispositivo Inrichting 1 Comando Command Commande Steuerung Comando Commando 2 Comando Command Commande Steuerung Comando Commando ID...

Страница 22: ......

Страница 23: ......

Страница 24: ...XTR B 14 3FW FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 758518 www faac it www faacgroup com...

Отзывы: