FAAC XTR B Скачать руководство пользователя страница 15

XTR B 

3FW#

SW2

2

3

SW2

SW2

 ~ 20 s

2

 2 s  1 

  , 

¿

 10 s  , 

Ä

 10 s  ,

 + 

z

 1 s  , 

{

SW2

 ~20 s

1

SW2

SW2

1

 2 s  N (

¿

 )  , 

z

1

  , 

¿

 10 s  , 

Ä

 10 s  ,  1 

 + 

z

 1 s  , 

{

® ®

N

 times  (N

 

= Group number)

3. DELETING ALL TAGS

!

This procedure permanently deletes all Tags from memory.

The XTR B must be in standby.

TOTAL DELETION

DELETING a GROUP

1. 

Press and hold the button throughout the entire 

sequence:

 

-

After 2 s, the XTR B will beep once and starts 

to flash for 10 s. The frequency of flashing then 

increases for another 10 s. Finally the XTR B will 

beep once and the LEDs turn on for 1 s: the Tags 

have been deleted.

 

-

The LEDs turn off: XTR B in standby.

2. 

Release the button.

To interrupt the deletion procedure, release the

button before the beep in step 

1

.  The LEDs turn

off: XTR B in standby.

4. DELETING A TAG GROUP

!

This procedure permanently deletes all the Tags of the Group.  The procedure is only active if the 

XTR B is connected to a BUS-RELAY interface.  In other cases, carry out the “Total Deletion” procedure.

The XTR B must be in standby.

1. 

Select the Group to delete:  press the button 

the same number of times as the number of the 

Group (e.g.: Group 3, press 3 times).

 

-

After 2 s, the XTR B will beep and flash the

same number of times as the number of the 

Group.  Then the LEDs will turn on steadily.

2. 

Press and hold the button throughout the entire 

sequence:

 

-

The XTR B will beep once and starts to flash for 

10 s. The frequency of flashing then increases 

for another 10 s. Finally the XTR B will beep 

once and the LEDs turn on for 1 s: the Group has 

been deleted.

 

-

The LEDs turn off: XTR B in standby.

3. 

Release the button.

To interrupt the deletion procedure, release the

button before the beep in step 

2

.  The LEDs turn

off: XTR B standby.

Note

:  If the XTR B signals an error at step 

1

 and 

then the LEDs turn off, carry out the “Total deletion” 

procedure.

Содержание XTR B

Страница 1: ...XTR B EN...

Страница 2: ...XTR B 2 3FW...

Страница 3: ...Leer las instrucciones C Eliminar seg n las directivas vigentes D Referencia Notified Body E Lugar de fabricaci n F Frecuencia Identificatielabelproduct A Identificatiecode van het model B De instruc...

Страница 4: ...mm 15 mm XTR B INOX XTR B GuarnizioneditenutaIP IPsealinggasket Jointd tanch it IP IPDichtung Junta de estanqueidad IP IP afdichting GuarnizioneditenutaIP IPsealinggasket Jointd tanch it IP IPDichtun...

Страница 5: ...asy Morsetti BUS 2easy Terminals BUS 2easy bornes BUS 2easy Klemmen BUS2easyBornes BUS2easyAansluitklemmen BZ1 Buzzer Buzzer Buzzer Buzzer Zumbador Buzzer DL2DL3 Led LED Led LED Led Led 0 5mm2 Sezione...

Страница 6: ...Guarnizione di tenuta IP IP sealing gasket Joint d tanc h it IP IP Dichtung Junta de estanqueidad IP IP afdichting Guarnizione di tenuta IP IP sealing gasket Joint d tanc h it IP IP Dichtung Junta de...

Страница 7: ...XTR B 05 3FW 4 5 5 click click XTR B INOX XTR B...

Страница 8: ...XTR B 06 3FW 6 SW1 BZ1 J7 J5 SW2 ON 1 2 3 4 5 SW1 BZ1 SW1 BZ1 J7 J5 SW2 ON 1 2 3 4 5 SW1 BZ1 XTRB A XTRB B A B A B A B...

Страница 9: ...Maintained action command 1 10 Maintained action command 2 10 8 ADDING TAGS 11 9 MAINTENANCE 11 EN Translation of the original instructions CEDECLARATIONOFCONFORMITY The Manufacturer Companyname FAAC...

Страница 10: ...The range also includes for example the XK10 XK11 and XKP B see catalogue The XTR B only recognises dedicated FAACTags see catalogue A limited number of Tags can be ena bled EachTagcanbeusedforanimpul...

Страница 11: ...ices that are alreadyinstalledinordertoidentifywhichcommandsarealreadyused Forfuturereference you canmakeanoteofthecommandsofalltheinstalleddevicesinthetableattheendofthismanual The configuration of B...

Страница 12: ...s storing enabled 3 Repeat step 2for furtherTags 4 To finish let 10 s pass without bringing any new Tags up to the reader or press the button immediately The LEDs turn off XTR B in standby Errorsduri...

Страница 13: ...4 irrelevant Each control device connected to the BUS RELAY interface must have a different ID LInordertoaddanXTRBtoanexistingsystemyoumustknowtheIDsoftheotherBUS2easydevices that are present See the...

Страница 14: ...enabled 4 To finish let 10 s pass without bringing any new Tags up to the reader or press the button immediately The LEDs turn off XTR B in standby Repeat the procedure to enable another Group At step...

Страница 15: ...ll theTags of the Group The procedure is only active if the XTRBisconnectedtoaBUS RELAYinterface Inothercases carryoutthe TotalDeletion procedure The XTR B must be in standby 1 Select the Group to del...

Страница 16: ...0s bringupaMasterTagalreadystored on the previous XTR B The XTR B will beep and flash the same number oftimesasthenumberoftheGroupandtheLEDs will come on for 2 s then flashing resumes 4 Press the butt...

Страница 17: ...adily 2 Move the Tag away when you wish to stop the command the LEDs turn off IMPULSECOMMAND2 1 With the XTR B in standby bring the Tag close to the reader and hold it there the XTR B beeps once and t...

Страница 18: ...away when you wish to stop the command the LEDs turn off MAINTAINEDACTIONCOMMAND2 1 With the XTR B in standby bring the Tag close to the reader and hold it there the XTR B beeps once and the LEDs will...

Страница 19: ...come on steadily 2 Move theTag away 3 Bring the previously stored MasterTag up to the reader within 10 s The LEDs still remain steady the XTR B will BEEP once 4 Move the MasterTag away within 5 s It...

Страница 20: ...XTR B 12 3FW Dispositivo Device Dispositif Vorrichtung Dispositivo Inrichting 1 Comando Command Commande Steuerung Comando Commando 2 Comando Command Commande Steuerung Comando Commando ID...

Страница 21: ...XTR B 13 3FW Dispositivo Device Dispositif Vorrichtung Dispositivo Inrichting 1 Comando Command Commande Steuerung Comando Commando 2 Comando Command Commande Steuerung Comando Commando ID...

Страница 22: ......

Страница 23: ......

Страница 24: ...XTR B 14 3FW FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 758518 www faac it www faacgroup com...

Отзывы: