ELECTRICAL CONNECTIONS
- In order to prevent dangerous situations or malfunctioning, the electrical
command elements wired to the motor must be sized according to the motor’s
electrical features.
- Means for disconnection must be incorporated in the fixed wiring in accordance
with the national installation standards.
- For outdoor use, provide the appliance with a supply cable with designation
H05RN-F containing at least 2% of carbon.
- If not used, the white or black wire must be insulated. It is dangerous to touch
the white or black wire when the motor is powered.
* Optional step by
step - Switch
brown
blue
white or black
green-yellow
* Installing this switch is optional. The connection can be done differently using
the brown wire or the blue wire. The switch affords the possibility to command the
motor in stepping mode (up, stop, down, stop, up, stop, down, stop..)