TM2
ERX
37
A4518_6G41_Rev.A
SPECIAL FUNCTIONS
SHORT-TERM SETTING OF A REMOTE CONTROL
This function makes it possible to store a remote control temporarily, for example,
with the purpose of setting the limit switches during assembly in the factory. A later
final saving of the remote control will be possible using the appropriate command
sequence (see: “SETTING THE FIRST REMOTE CONTROL”). The operations described
below can be carried out only when the motor has just come out of the factory or
after a full memory clearing (see: “FULL MEMORY CLEARING”). The motor makes
the following operations possible only within the time limits described in order
to make sure that the short-term setting is used only in the installation or factory
setting phase and not during daily use.
Power up the motor, make sure that no other motors having an empty memory are
powered up in the same operating range.
Within 30 seconds after start
, press the B and C buttons simultaneously until the
motor gives a confirmation signal.
The remote control will remain stored for 5 minutes
, while the motor is powered up.
After 5 minutes or when the motor has its power cut off, the remote control will
be cancelled.
T1: First remote control to be set
T1
+
B
C
EN