manualshive.com logo in svg
background image

4

FAAC Model S450H 24V Hydraulic Swing Gate Operator

Gate Construction

Vehicular gates should be constructed and installed 

in accordance with ASTM F2200: Standard Specifica

-

tion for Automated Vehicular Gate Construction. 

For more information, contact ASTM at: 

www.astm.org

Installation

• 

If you have any questions or concerns regarding the 

safety of the gate operating system, do not install the 

operator and consult the manufacturer. 

• 

The condition of the gate structure itself directly 

affects the reliability and safety of the gate operator.

• 

Only qualified personnel should install this equipment. 

Failure to meet this requirement could cause severe 

injury and/or death, for which the manufacturer 

cannot be held responsible.

• 

The installer must provide a main power switch that 

meets all applicable safety regulations.

• 

It is extremely unsafe to compensate for a damaged 

gate by increasing hydraulic pressure.

• 

Install devices such as reversing edges and photo 

beams to provide better protection for personal 

property and pedestrians. Install reversing devices 

that are appropriate to the gate design and 

application.

• 

Before applying electrical power, ensure that voltage 

requirements of the equipment correspond to the 

supply voltage. Refer to the label on your gate 

operator system.

Usage

• 

Use this equipment only in the capacity for which it 

was designed. Any use other than that stated should 

be considered improper and therefore dangerous.

• 

The manufacturer cannot be held responsible 

for damage caused by improper, erroneous or 

unreasonable use. 

• 

If a gate system component malfunctions, disconnect 

the main power before attempting to repair it.

• 

Do not impede the movement of the gate, you may 

injure yourself or damage the gate system as a result.

• 

This equipment may reach high thermal temperatures 

during normal operation, therefore use caution when 

touching the external housing of the gate operator.

• 

Use the manual release mechanism according to the 

procedures presented in this manual.

• 

Before performing any cleaning or maintenance 

operations, disconnect power to the equipment.

• 

All cleaning, maintenance or repair work must 

performed by qualified personnel.

General Safety Precautions

9.  For gate operators that utilize a contact sensor (edge 

sensor or similar): 

• 

Locate one or more contact sensors where the risk 

of entrapment or obstruction exists, such as at the 

leading edge, trailing edge, and post mounted both 

inside and outside of a vehicular horizontal slide 

gate

• 

Locate one or more contact sensors at the bottom 

edge of a vehicular vertical lift gate.

• 

Locate one or more contact sensors at the bottom 

edge of a vertical barrier (arm).

• 

Locate one or more contact sensors at the pinch 

point of a vehicular vertical pivot gate.

• 

Locate hard-wired contact sensors and wiring so 

that communication between sensor and gate 

operator is not subjected to mechanical damage.

• 

Locate wireless contact sensors, such as those 

that transmit radio frequency (RF) signals, where 

the transmission of signals are not obstructed or 

impeded by building structures, natural landscaping 

or similar hindrances. Wireless contact sensors shall 

function under their intended end-use conditions.

• 

Use only FAAC MSE MO, CN60 or M60 edge 

sensors.

Important Installation Instructions (continued)

Содержание S450H

Страница 1: ...ernational Inc Headquarter East Coast Operations 5151 Sunbeam Road Suites 9 11 Jacksonville FL 32257 Tel 866 925 3222 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Aven...

Страница 2: ...ON 3 Important Safety Instructions 3 Important Installation Instructions 3 General Safety Precautions 4 UL325 Gate Operator Classifications 5 Installing the Warning Signs 5 1 DESCRIPTION AND TECHNICAL...

Страница 3: ...or Reset buttons must be located within line of sight of the gate Activation of the reset control shall not cause the operator to start 7 All warning signs and placards must be installed and easily s...

Страница 4: ...nreasonable use If a gate system component malfunctions disconnect the main power before attempting to repair it Do not impede the movement of the gate you may injure yourself or damage the gate syste...

Страница 5: ...ildings such as factories loading docks or other locations not intended to service the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator system intended for u...

Страница 6: ...Not necessary when using opening mechanical stops inside the operator Fig 1 Ref 7 3 INSTALLING THE AUTOMATED SYSTEM Ensure that the following conditions have been met to ensure safety and the efficie...

Страница 7: ...Z a 3 a 2 D a 1 3 2 1 TAB 1 B XXX XXXX D XXX 120 3 120 3 XXX 110 2 110 2 XXX 115 1 110 1 a B ATTENTION do not cut the rear bracket for any reason Refer to Figures 4 and 5 and Table 1 to determine the...

Страница 8: ...2 95 3 97 3 7 65 8 0 90 1 90 1 95 1 90 2 90 2 95 2 90 3 95 3 8 0 8 45 90 1 90 1 90 2 90 2 90 2 90 3 90 3 8 5 8 8 90 1 89 2 90 2 90 2 90 2 90 3 90 3 Z a 3 a 2 D1 a 1 3 2 1 TAB 2 B1 XXX XXXX D1 XXX 115...

Страница 9: ...Tab 1 never cut the rear fitting moreover it must be installed with the word UP facing up as shown in Figure 6 Ref a a b c Fig 8 b a Fig 10 Fig 11 6 Screw one half of the thread of the front articula...

Страница 10: ...7 Remove the front ar ticulated joint and insert on the rod the number of spacers required to reach the desired opening angle Fig 14 If an external mechanical stop point at closure is present extend...

Страница 11: ...ring leaf movement Leaf stationary DL 1 must always be ON to ensure the right connection between encoder and board DL 2 identifies the leaf to which the encoder is installed If the encoder is installe...

Страница 12: ...CKET COVER OF LEAF 1 VERIFY THAT THE LEDS DL1 AND DL2 ARE ON WHEN THE MOTOR IS NOT IN OPERATION LEAF 1 TWO LEDS ON THROUGH THE BRACKET COVER OF LEAF 2 VERIFY THAT THE LED DL1 IS ON WHEN THE MOTOR IS N...

Страница 13: ...be careful with the O ring that must remain it its seat 4 Remove all spacers if present Fig 25 5 Tilt the operator upward as much as possible Do not force the rear fitting too much 6 Supply the operat...

Страница 14: ...R CARTER S450H 07 7119405 CAP FOR HOLES COVER CARTER 08 7073035 M10 JOINT 09 702101 HEX NUT 10 5588 5S Z 10 703027 WASHER 10 6593 CAT C R40 Z 11 63001945 S450H FRONT FASTENING Part Part Number Descrip...

Страница 15: ...6 TC M4X30 TORX T20 INOX DE 7 12 63000626 S450H MOTOR COVER KIT 13 63000636 S450H MOTOR ASSEMBLY 14 63000806 S450H REAR FLANGE 15 63000786 S450H TIE ROD 16 703121 WASHER GROWER M5 A2 UNI 1751 INOX Par...

Страница 16: ...5 GASKET OR 10 82X1 78 2043 04 4404085 STOP VALVE IN ZAMACK 05 7090350025 GASKET OR 34 60X2 62 3137 06 7090280015 GASKET OR 5 28X1 78 2021 07 63000826 RELEASE VALVE S450H Part Part Number Description...

Страница 17: ...ic Operator Diagram 4 Emergency Lock Release Part Part Number Description 01 63001985 RELEASE ASSY S450H 02 7290445 2005 RELEASE HAND GRIP 03 7090895 21X2 N70B200V SEAL 04 7131005 KEY MOD 3889 0913 05...

Отзывы: