![FAAC S450H Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/faac/s450h/s450h_instructions-for-intallation_3223174013.webp)
13
FAAC Model S450H 24V Hydraulic Swing Gate Operator
b
a
6. BLEEDING
2. Remove the screw in Fig. 24 ref.d
from the front fitting
3. Remove the joint (Fig.24 ref.f) from the operator stem.
(Fig. 24 ref. g).
1. Loosen the tie-rods (Fig. 23 ref. a) and remove the metal
protective housing (Fig. 23 ref. b)
.
Remove the upper tie-rod and be careful with the
O-ring that must remain it its seat.
4. Remove all spacers, if present (Fig. 25).
5. Tilt the operator upward as much as possible. Do not force
the rear fitting too much.
6. Supply the operator with power and repeatedly move the
stem in and out, over its complete stroke, until reaching a
smooth movement (Fig. 27).
7. After bleeding, repeat the operations described above in
reverse order.
TO PREVENT OIL LEAKAGE FROM
THE BREATHER HOLE, DO NOT TILT THE
OPERATOR DOWNWARD
Fig.23
d
f
g
Fig.24
Fig.26
Fig.25
Fig.27