![FAAC S450H Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/faac/s450h/s450h_instructions-for-intallation_3223174007.webp)
7
FAAC Model S450H 24V Hydraulic Swing Gate Operator
TAB. 1
B
2.95-3.3
3.35-3.7
3.75-4.0
4.1-4.45
4.5-4.85
4.9-5.25
5.3-5.65
5.7-6.0
6.1-6.45
6.5-6.85
D
0.75-0.95
110° (3)
110° (3)
115° (3)
108° (3)
100° (3)
100° (3)
1.0-1.3
108° (3)
110° (3)
110° (3)
103° (3)
100° (3)
94° (3)
1.35-1.7
100° (3)
107° (3)
108° (3)
104° (3)
111° (2)
104° (2)
100° (2)
1.75-2.1
100° (3)
105° (3)
106° (3)
100° (3)
106° (2)
100° (2)
96° (2)
2.15-2.5
97° (3)
100° (3)
105° (3)
99° (3)
107° (2)
100° (2)
96° (2)
92° (2)
2.6-2.9
93° (3) 97° (3)
100° (3)
100° (3)
110° (2)
101° (2)
96° (2)
102° (1)
98° (1)
2.95-3.3
90° (3) 95° (3)
100° (3)
105° (2)
102° (2)
111° (1)
105° (1)
98° (1)
94° (1)
3.35-3.7
90° (3) 90° (3) 95° (3)
100° (2)
104° (2)
96° (2)
104° (1)
100° (1)
94° (1)
90° (1)
3.75-4.0
90° (3) 90° (3) 95° (3)
100° (2)
96° (2)
106° (1)
98° (1)
96° (1)
90° (1)
4.1-4.45
90° (3) 90° (3) 95° (2)
97° (2)
103° (1)
99° (1)
94° (1)
92° (1)
4.5-4.85
90° (3) 90° (2) 95° (2)
98° (1)
100° (1)
94° (1)
4.9-5.25
90° (2) 90° (2) 95° (1)
98° (1)
94° (1)
5.3-5.65
90° (2) 90° (2) 95° (1)
94° (1)
5.7-6.0
90° (1) 90° (1) 94° (1)
6.1-6.45
90° (1) 90° (1)
6.5-6.75
90° (1)
3⅜
41¾
2
3
4
Z
a
° (3)
a
° (2)
D
a
° (1)
(3)
(2)
(1)
TAB.1
B
XXX
XXXX
D
XXX
120° (3)
120° (3)
XXX
110° (2)
110° (2)
XXX
115° (1)
110° (1)
a
B
ATTENTION: do not cut the rear bracket for any reason.
Refer to Figures 4 and 5 and Table 1 to determine the installation position of the operator.
INSTALLATION DIMENSION "B"
(SEE FIGURES 4 and 5)
INSTALLATION
DIMENSION
"D"
(SEE FIGURE 5)
- INTERSECT THE DIMENSIONS "D" AND "B" TO OBTAIN THE MAXIMUM VALUE OF OPENING ANGLES.
- ATTENTION: USE MECHANICAL LIMIT SWITCHES IN ORDER NOT TO EXCEED THE MAXIMUM OPENING ANGLES STATED IN TABLE 1 AND GUARANTEE
THE CORRECT OPERATION OF THE AUTOMATED SYSTEM.
HOLE TO BE USED
ON THE REAR
BRACKET
HOLE TO BE USED ON THE REAR BRACKET
Dimensions in Inches
Fig. 4
Fig. 5
Dimensions in Inches
3.1
INSTALLATION DIMENSIONS
3.1.1 APPLICATION WITH BRACKET FASTENED TO THE COLUMN
- -
If the gate structure does not allow the stable fixing of the front fitting, create a firm bearing surface in the leaf structure.
- It is advisable to grease all fixing pins - Opening and closing stops must always be installed - Pay special attention not to
damage the operator rod.