To ensure that the various modules used by the Ticket Reader 

operate in optimum conditions, a temperature of  22° Celsius must 

be maintained inside the column. This characteristic will ensure 

that the laser scanner operates at its best, when the ticket is read. 

This is in addition to eliminating any condensation accumulated 

inside, due to possible temperature ranges between day and night. 

We therefore advise you to always power the Ticket Dispenser 

and adjust the thermostat knob to 22°C.

 

 6.  CONTROL UNIT

 6.1  P.LITE COBRA BOARD 

The Ticket Reader electronic control unit is defined as: 

Cobra 

P.Lite

. It has specifically created firmware for commanding all 

devices which need to be controlled on the exit lane from the 

parking area.

The board manages some processes in a fully independent way, 

whereas others can be subordinated through the board to the 

ParkLite management software.

We must underscore the fact that every equipment for treating 

tickets and cards in the ParkLite system uses this type of unit.

The various devices of the system (Ticket Dispenser, Ticket 

Reader, Cash Desk, etc) make use of this control board with 

the same firmware. The function to which the equipment is 

addressed, is acquired by inserting a jumper, located on the 

board’s CN1 connector.   

Whenever the Ticket Reader is powered up, the Cobra P.Lite 

control unit controls the function to which it is delegated, 

through the jumper fitted on the CN1 connector, and it sets 

itself to manage all the specified devices for that use. 

Therefore this jumper must be correctly fitted.

Obviously, the Ticket Reader is supplied with the jumper 

already set in the right position. Fig.15 shows all the settings 

which can be carried out on the management unit. This figure 

is included in order to be used, if this board has to be replaced 

on the equipment.   

 6.3 RS485 LINE TERMINATION

On the Cobra P.Lite board, there is a connector which makes 

it possible to fit a 120 Ohm termination resistor on the RS485 

data transmission line.

We should stress that this resistor must be fitted 

only if the 

equipment is located on one of the ends of the line section. 

Use the CN8 connector to fit this resistor.

Figure 15 shows the insertion of this characteristic.

Set-up of function jumper and insertion of termination resistor

 5.2  THERMOSTAT ADJUSTMENTS 

 6.2  JUMPER FUNCTION 

Fig. 15

Set-up of function Jumper

NB: make sure that the jumper is positioned between E and F of CN1.

Termination resistor on RS485 network

Position of Jumper in CN1 Description of function

A

TICKET DISPENSER

B

CASH-DESK (ON LANE OR DECENTRALISED)

C

SUBSCRIPTION (VEHICULAR)

D

SUBSCRIPTION (PEDESTRIAN)

E

TICKET READER

Position of Jumper in CN8 Description of function

DOWN (Toward ALI board) 120 OHM RESISTOR NOT INSERTED

R (UP)

120 OHM RESISTOR INSERTED

Cobra P.Lite board

Содержание ParkLite TR

Страница 1: ...TR ParkLite rev A INSTALLATION MANUAL Ticket Reader ParkLite Ticket Reader ParkLite ...

Страница 2: ...irectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendment 92 31 EEC and 93 68 EEC and also conforms to the following standards EN 50081 1 EN 60555 2 IEC 801 2 EN 50082 1 EN 60555 3 IEC801 3 EN 60335 1 EN 55022 IEC 801 4 EN 60204 1 EN 55014 Additional notes This product underwent a test in a typical uniform configuration all products of FAAC S p A Bologna 01 January...

Страница 3: ...9 The installation must be carried out by observing standards EN12453 and EN12445 10 Before attempting any action on the system cut out the electrical power supply 11 Install an omnipolar switch upstream of the power supply line for the ParkLite Ticket Reader with contact opening distance of 3 mm or more We advise you to use a 6A thermal breaker with omnipolar switching 12 Make sure that a differe...

Страница 4: ...NDINGS 2 4 MASONRY PREPARATIONS 2 4 1 LAYING THE FOUNDATION PLATES 2 4 2 FASTENING 2 5 COMPONENT DIMENSIONS 2 6 PREPARATION OF CHANNELS 2 7 POSITION OF EQUIPMENT 3 ELECTRICAL PREPARATIONS 3 1 SAFETY INSTRUCTIONS 3 2 TYPES OF CABLES 4 ELECTRICAL CONNECTIONS 4 1 CONNECTIONS ON INTERFACE BOARD 4 2 DATA TRANSMISSION LINES 4 3 INTERCOM CONNECTION 5 SETTING OF COMPONENTS 5 1 DETECTOR CONFIGURATION 5 2 T...

Страница 5: ...can be connected to a specific intercom control unit optional which enables the operator to remotely communicate with the user situated on the exit lane Connection with two magnetic loops able to detect the pre sence and transit direction of the vehicle is obligatory for all models The engagement and disengagement of these sensors allows the Ticket Reader to enable the ticket card reading modules ...

Страница 6: ...OL UNIT COBRA 5000 P Lite board RAM CONTROL UNIT 512 KByte USER CAPACITY 5000 EVENT CAPACITY 15000 BARCODE READER One way laser scanner SCANNING RESOLUTION 16 lines SCANNING SPEED 1200 per second READ TICKET DETECTION Barcode with 22 characters 2 5 interleaved Tab 1 Characteristics present on all ParkLite Ticket Reader models Tab 2 Characteristics present only on ParkLite TR TAG Tab 3 Characterist...

Страница 7: ...ndicated in paragraph 3 2 Type of cables Furthermore all the instructions in paragraph General safety rules on page 3 must be respected and with reference to the specific electrical preparations as described in paragraph 3 1 Safety rules The Ticket Reader was designed to manage automatically the exit of vehicles from a parking area Therefore transit by pedestrians must be forbidden in the area res...

Страница 8: ...le insulation cable with a cross section of 1 5 mm2 inside it and then lay the loop thus constructed inside the chase NB in both cases respect the requirements specified in point 2 3 1 described up to here around the perimeter in which it must be constructed Procedure for the above operation insert the cable end from the sharp edge providing access into the chosen seat next run it inside for a set...

Страница 9: ...ow the dimensions in millimetres of the main lane equipment 2 4 MASONRY PREPARATIONS The foundation plate for securing the Ticket Reader is identical to the one used for installing the 620 barrier The drawing be low shows the dimensions and methods for laying them both 2 4 1 LAYING THE FOUNDATION PLATES Ticket Reader Dimensions Fig 6 Dimensions of 620 Barrier Fig 7 Dimensions in mm Fig 5 The dimen...

Страница 10: ...ercom serial data line etc Furthermore appropriately size the diameter of the cable ducts to be laid in relation to the cross section and number of cables to be inserted To this end please refer to section 3 Electrical preparations of this manual Channel lay out for Exit lane Driving direction 1 Input of Ticket Reader power cables 2 Input and output of cables for data transmission line on RS 485 p...

Страница 11: ...switch with a threshold of 0 03A is installed upstream of the system Make sure that the earthing system is expertly made and connect to it the metal parts of the closing element Apply all the instructions described in the preceding points to all the lane devices in addition to the Ticket Reader Fig 12 Foundation plate for ParkLite column Foundation plate for 620 rapid barrier RH version Driving di...

Страница 12: ...col All devices must be multidrop connected as shown in lay out Data Line Connections 5 Shielded cable for intercom 2 x 1 5 mm if Legacy model Telephone pair 0 4 mm 275 Ohm Km Line Double wire or telephone pair 0 6 mm 122 Ohm Km Line Double wire if Deluxe model 6 Flame retardant cable 2 x 0 5 mm input for barrier closure safety 7 Flame retardant cable 3 x 0 5 mm open closed barrier commands Power ...

Страница 13: ...op output C Transit loop output NC Presence loop output NA Presence loop output C Presence loop output Input 6 additional Common input Comune Open Closed Barriera Closed Barrier Open Barrier Input 2 Input 6 Additional inputs Vehicle detection loops on exit lane 620 640 barrier configured in P logic Barrier photocell 620 640 barrier configured in P logic Sch RS 485 Polling Out RS 485 Polling Out RS...

Страница 14: ...stem uses NET stations both the concentrator PC and the NET PC must have a static address assigned to them The fundamental parameters for network connection between PCs such as IP address Netmask Gateway etc must be supplied by the customer s network administrator RS 485 Data transmission line Use a paired twisted and screened cable for transmission on data network with RS 485 protocol type Belden...

Страница 15: ...tely for each channel It is essential to differentiate the frequency among the channels of the detectors which command two adjacent loops in order to avoid any kind of noise Presence time and reset Dip switches 3 and 7 enable you to set a continuous detection time of 5 minutes after which a reset and a consequent self set are performed automatically This type of setting is normally not recommended...

Страница 16: ...et Reader is powered up the Cobra P Lite control unit controls the function to which it is delegated through the jumper fitted on the CN1 connector and it sets itself to manage all the specified devices for that use Therefore this jumper must be correctly fitted Obviously the Ticket Reader is supplied with the jumper already set in the right position Fig 15 shows all the settings which can be carr...

Страница 17: ...d Output 1 M7 CN1 on Interface board Closed Barrier Command Output 2 M6 Not connected Output 3 M5 Not connected Output 4 M4 CN2 on Interface board Inputs loops engage disengage in5 and in1 area down count or reserve remaining M13 Ticket Reader Scanner Receive the data of the ticket read by the laser scanner Pratic 503 Destination Function CM1 M1 on Cobra P Lite board Connection of reader input to ...