FAAC H4 Скачать руководство пользователя страница 24

24

READ THIS BEFORE ANY USE

„

„

Wait for the end of the phrases before pressing the keys, when carrying out the different

configurations and consultation of the system.

„

„

The transmitter will automatically disconnect itself if no pressure is exerted for 90 seconds.

„

„

To return at any time to the main menu, starting off from any function, press key       of the telephone.

Likewise, 2 successive pressings of key       enable you to hang up.

„

„

Any non-confirmed modification of parameters (no pressure of the indicated push-button, exiting

the function before finishing, etc…) will not be considered.
The old parameters will be maintained (time, date, access code, etc…).

„

„

How to access the main menu

Starting from a telephone line (fixed or mobile):

- type the telephone number of the line to which the
control unit is connected,
- allow to ring once or twice, then hang up,
- wait for 10 seconds, and then call again within one
minute.

The transmitter engages the line and asks you to
type the access code:

- type in the 6 digits of the access code (1 2 3 4 5 6
by default).
The transmitter communicates the system status,
internal temperature and, later, your main menu.

You can now:
- modify the system's status (ON or OFF),
- listen to what is happening in the rooms where the
transmitter is installed,
- speak so you can be listened to in the protected
rooms,
- customise the transmitter (if the control unit is in
MAINTENANCE PROGRAM mode),
- hang up.

„

„

How to confirm reception of an event

Until a given alarm is encountered, it is
communicated to the transmitter at every new
access. To confirm the reception of the alarm:

- access to the main menu,
- press the 0 push-button.

You may now hang up.

Allow to ring once or twice,

hang up,

wait for 10 seconds.

Main menu

To enable the alarm system, press 1,
To listen, press 2,
To speak, press 3,
To customise the transmitter, press 4,
To hang up, press          twice

Main menu,

To delete the alarm, press 0, 
To enable the alarm system, press 1, 
......

#

Call

Access code

Call again

Hello, type in the access code

Alarm disabled, no signals, indoor temperature is 21 
degrees

Delete the alarm

MANAGEMENT BY TELEPHONE

#

Содержание H4

Страница 1: ...de 2 secs Alarm memory stored In progress System sabotage alarm Discharged batteries Peripheral units fault Telephone line fault Passage open signal Installation and use instructions H4 Alarm Control...

Страница 2: ...2...

Страница 3: ...Areas 15 4 CUSTOMISING THE SYSTEM Access to the telephone transmitter 16 Modifying the system parameters 17 Control Unit internal functions 19 System test 20 5 USE Status diagram use with radio contr...

Страница 4: ...ovement detector Opening detector Alarm control unit with siren and telephone transmitter 3 Analyse process Alarm ON Alarm OFF Maintenance Program mode 2 secs Alarm memory stored In progress System sa...

Страница 5: ...area The control unit can protect the whole of an ambient room or just part of it AMBIENT TO BE PROTECTED first floor staircases garage ground floor AREA 4 AREA 2 SYSTEM MODE ON AREA 3 AREA 1 Each de...

Страница 6: ...Maintenance Program mode Alarm ON Alarm OFF Passage open signal Peripheral units fault Telephone line fault Discharged batteries System sabotage alarm Alarm memory stored In progress PRESENTATION OF H...

Страница 7: ...d on steady beam EFF TEST Fault indicator lights Detector Remote control Control keypad Telephone transmitter Siren Alarm memory stored In progress Sabotage memory stored Sabotage in progress except c...

Страница 8: ...t of about 1 5 m from 90 to 100 from 10 to 70 from 65 to 95 from 0 to 10 plaster wood plasterboard reinforced concrete brick agglomerate metal metallic protection Radio wave propagation rate not recom...

Страница 9: ...te Insert the cable with the RJ11 plug taking care not to crush it Connect the RJ11 plug to the control unit via the supplied pre wired socket long side Connect the RJ11 plug to the entry point of the...

Страница 10: ...control unit is in Maintenance Program mode and is ready to memory store the control keypad as the first element AP EFF TEST Passage open signal Peripheral units fault Telephone line fault Discharged...

Страница 11: ...it supplies status and alarm information Status Closed contact alarm system enabled Open contact alarm system disabled Alarm output of alarm in progress open collector The output which is normally flo...

Страница 12: ...e control Time to carry out this operation is limited Procedure Press the future ON key for 10 seconds the control unit beeps once and goes into Add Devices menu The yellow operation indicator light c...

Страница 13: ...ve remote control you have to work in steps in a limited time period Step 1 synchronise the slave remote control with the master remote control Bring the two remote controls forward so that they touch...

Страница 14: ...ed To eliminate one device at a time Select the DELETE DEVICES menu on the control keypad and confirm Select the device to be eliminated by pressing keys and or by directly pressing the TEST push butt...

Страница 15: ...TEST push button of the detector assigned to the area The screen shows the relevant identity of every allocated detector To access the other areas press the key of the keypad and select the area you r...

Страница 16: ...hone answering system or other automatically enabled equipment The control unit must be in MAINTENANCE PROGRAM mode See Alarm Control Unit Instructions Wait for 1 2 ring tones Tuu Wait for 5 10 ring t...

Страница 17: ...gistered type in the telephone number and confirm by pressing The transmitter asks you to type in the position of another telephone number to be modified Repeat the operation for everyone of the 4 tel...

Страница 18: ...omising menu or hang up HOW TO MODIFY THE DATE access the customising menu press push button 5 of the telephone The transmitter shows the recorded date and then invites you to type in the 6 digits of...

Страница 19: ...quency battery saving AP SUP TEST 2 secs Passage open signal Peripheral units fault Telephone line fault Discharged batteries Alarm memory stored In progress Maintenance Program mode Alarm ON Alarm OF...

Страница 20: ...perating correctly For security reasons the test should be run whenever a device is added before a long period of absence and in any event regularly Remote control test When the ON or OFF keys of the...

Страница 21: ...arm is tripped by simulating an intrusion e g open a door on which an opening detector is installed Make sure that the telephone call was interrupted Test for checking if the external telephone call i...

Страница 22: ...mode on Press OFF ADD DEVICES Press the ON key for a long time Press 1 2 and then press the OFF Key for a long time Master only Press OFF Close the battery compartment Open the battery compartment you...

Страница 23: ...typing in the real access code whereas a telephone call is tripped without any acoustic signal To do this you have to add a unit to the first digit of your keypad access code and then select OFF For e...

Страница 24: ...asks you to type the access code type in the 6 digits of the access code 1 2 3 4 5 6 by default The transmitter communicates the system status internal temperature and later your main menu You can no...

Страница 25: ...point the transmission control unit allows the user to speak in the protected rooms or to change over to the function Listen to the protected rooms by pressing push button 2 You can speak and be list...

Страница 26: ...up Access the customising menu The control unit must be in MAINTENANCE PROGRAM mode access the main menu press push button 4 of the telephone The transmitter indicates the customising menu You can now...

Страница 27: ...en to the protected rooms speak in the protected rooms confirm reception of the call Select one of the suggested functions or hang up Intrusion alarm press You are communicating with your Home Shield...

Страница 28: ...ssage open signal Peripheral units fault Telephone line fault Discharged batteries System sabotage alarm Alarm memory stored In progress A device is present No devices A detector is present in the are...

Страница 29: ...rogress Indicator light This lights up when an intrusion or technical alarm is stored in the memory It remains lighted until manual confirmation by the alarm itself Self protection Indicator light It...

Страница 30: ...nce as shown at the side here The transmitter exits the cycle as soon as the call reception confirmation code push button 4 is received or when the cycle has been performed 4 times for numbers 1 2 and...

Страница 31: ...ring tone hang up and wait for 10 seconds retype in the number within one minute The transmitter will answer after one ring tone You are connected to your Home Shield Alarm ON Alarm OFF Maintenance Pr...

Страница 32: ...status 300 mA Average consumption in transmission status 50 mA Self protection at opening and removal Radio frequency 434 and 868 MHz band Radio range in free field from 200 to 300 m according to envi...

Страница 33: ...ector Transmitter OFF ON 2 Immediate Delayed OFF ON 3 NC NO OFF ON TRANSMISSION CONTROL UNIT 1 Indoor siren OFF enabled 2 Siren confirmation acoustic level OFF loud 3 Control unit supervision ON enabl...

Страница 34: ...and correct reception of the radio transmissions during the tests Parameter Used for defining the type of signal sirens Radio Range The distance at which a device in a radio system remote control dete...

Страница 35: ...60950 October 2000 Electromagnetic compatibility EN 301489_3 July 2000 NF EN 50130_4 April 1995 A1 1998 Effective use of the radioelectric spectrum EN 300 220_3 V1 1 1 September 2000 EN 300 220_1 V1 3...

Страница 36: ...illustrations in this manual are not binding While leaving the essential characteristics of the equipment unaltered FAAC reserves the right at any time and without having to update this publication t...

Отзывы: