READ THIS BEFORE ANY USE
Wait for the end of the phrases before pressing the keys, when carrying out the different
configurations and consultation of the system.
The transmitter will automatically disconnect itself if no pressure is exerted for 90 seconds.
To return at any time to the main menu, starting off from any function, press key of the telephone.
Likewise, 2 successive pressings of key enable you to hang up.
Any non-confirmed modification of parameters (no pressure of the indicated push-button, exiting
the function before finishing, etc…) will not be considered.
The old parameters will be maintained (time, date, access code, etc…).
How to access the main menu
Starting from a telephone line (fixed or mobile):
- type the telephone number of the line to which the
control unit is connected,
- allow to ring once or twice, then hang up,
- wait for 10 seconds, and then call again within one
minute.
The transmitter engages the line and asks you to
type the access code:
- type in the 6 digits of the access code (1 2 3 4 5 6
by default).
The transmitter communicates the system status,
internal temperature and, later, your main menu.
You can now:
- modify the system's status (ON or OFF),
- listen to what is happening in the rooms where the
transmitter is installed,
- speak so you can be listened to in the protected
rooms,
- customise the transmitter (if the control unit is in
MAINTENANCE PROGRAM mode),
- hang up.
How to confirm reception of an event
Until a given alarm is encountered, it is
communicated to the transmitter at every new
access. To confirm the reception of the alarm:
- access to the main menu,
- press the 0 push-button.
You may now hang up.
Allow to ring once or twice,
hang up,
wait for 10 seconds.
Main menu
To enable the alarm system, press 1,
To listen, press 2,
To speak, press 3,
To customise the transmitter, press 4,
To hang up, press twice
Main menu,
To delete the alarm, press 0,
To enable the alarm system, press 1,
......
#
Call
Access code
Call again
Hello, type in the access code
Alarm disabled, no signals, indoor temperature is 21
degrees
Delete the alarm
MANAGEMENT BY TELEPHONE
#