17
LOGIC "AP"
PULSES
STATUS OF AUTOMATED SYSTEM
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and recloses after
the pause time
opens the gate partially
time B
no effect
no effect
(OPEN inhibited)
no effect
(OPEN inhibited)
no effect
no effect
(OPEN inhibited)
DURING OPENING
locks operation (1)
locks operation
recloses the gate
locks operation
see 2nd level prog.
no effect
locks and opens on
disengagement (OPEN
locks - stores CLOSE)
OPEN IN PAUSE
locks operation (1)
locks operation
recloses the gate
locks operation
no effect
reloads pause time
(CLOSE inhibited)
reloads pause time
(CLOSE inhibited)
DURING CLOSING
reopens the gate
reopens the gate
no effect
locks operation
no effect
reverses to opening (see
2nd level prog.)
locks and opens on
disengagement (OPEN
locks - stores CLOSE)
LOCKED
closes the gate
closes the gate
closes the gate
no effect
(OPEN/CLOSE inhibited)
no effect
(OPEN inhibited)
no effect
(CLOSE inhibited)
no effect
(OPEN/CLOSE inhibited)
LOGIC "At" (2)
PULSES
STATUS OF AUTOMATED SYSTEM
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and recloses after
the pause time
opens the gate partially
time B
no effect
no effect
(OPEN inhibited)
no effect
(OPEN inhibited)
no effect
no effect
(OPEN inhibited)
DURING OPENING
no effect (1)
no effect
recloses the gate
locks operation
reverses to closing (1)
no effect
locks and opens on
disengagement
(stores CLOSE)
OPEN IN PAUSE
reloads pause time (1)
reloads pause time
recloses the gate
locks operation
no effect
reloads pause time
(CLOSE inhibited)
reloads pause time
(CLOSE inhibited)
DURING CLOSING
reopens the gate
reopens the gate
no effect
locks operation
no effect
reverses to opening (see
2nd level prog.)
locks and opens on
disengagement
(stores CLOSE)
LOCKED
closes the gate
closes the gate
closes the gate
no effect
(OPEN/CLOSE inhibited)
no effect
(OPEN inhibited)
no effect
(CLOSE inhibited)
no effect
(OPEN/CLOSE inhibited)
LOGIC "S"
PULSES
STATUS OF AUTOMATED SYSTEM
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and recloses after
the pause time
opens the gate partially
time B
no effect
no effect
(OPEN inhibited)
no effect
(OPEN inhibited)
no effect
no effect
(OPEN inhibited)
DURING OPENING
reverses to closing (1)
reverses to closing (1)
recloses the gate
locks operation
see 2nd level prog.
continues to open and
recloses immediately
on
locks and opens
disengagement (stores
CLOSE)
OPEN IN PAUSE
recloses the gate (1)
recloses the gate
recloses the gate
locks operation
no effect
locks and immediately
closes on disengagement
locks and closes on
disengagement
DURING CLOSING
reopens the gate
reopens the gate
no effect
locks operation
no effect
reverses to opening (see
2nd level programming) and
closes immediately at the
end
locks and on disengage-
ment opens and at the
end immediately closes
LOCKED
closes the gate
closes the gate
closes the gate
no effect
(OPEN/CLOSE inhibited)
no effect
(OPEN inhibited)
no effect
(CLOSE inhibited)
no effect
(OPEN/CLOSE inhibited)
LOGIC "SP"
PULSES
STATUS OF AUTOMATED SYSTEM
OPEN A
OPEN B
CLOSE
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and recloses after
the pause time
opens the gate partially
time B
no effect
no effect
(OPEN inhibited)
no effect
(OPEN inhibited)
no effect
no effect
(OPEN inhibited)
DURING OPENING
locks operation (1)
locks operation
recloses the gate
locks operation
see 2nd level prog.
continues to open and
recloses immediately
locks and on disengagement opens
and at the end immediately closes
(OPEN locks - stores CLOSE)
OPEN IN PAUSE
recloses the gate (1)
recloses the gate
recloses the gate
locks operation
no effect
locks and immediately
closes on disengagement
locks and immediately
closes on disengagement
DURING CLOSING
locks operation
locks operation
no effect
locks operation
no effect
reverses to opening (see
2nd level prog.)
locks and opens on
disengagement
(stores CLOSE)
LOCKED
resumes motion in reverse
direction. After STOP, always
closes
resumes motion in reverse
direction. After STOP, always
closes
recloses the gate
no effect
(OPEN/CLOSE inhibited)
no effect
(OPEN inhibited)
no effect
(CLOSE inhibited)
no effect
(OPEN/CLOSE inhibited)
ENGLISH
and closes it after pause
and closes it after pause
and closes it after pause
and closes it after pause
(1) During the partial opening cycle, an OPEN A pulse causes total opening