10
ENGLISH
Display
Function
Default
1
PO
PARTIAL OPENING:
It is possible to adjust the width of the partial leaf opening as a percentage of the total gate
travel.
Adjustable from 0 to 99% in 1% steps.
00
= no partial opening
01
= minimum partial opening
99
= maximum partial opening
50
t
TIME-OUT
It is advisable to set a value higher than the time taken by the gate to open or close fully.
Adjustable from
0
to
59
sec. in 1 second steps. Subsequently, display changes to minutes
and tens of seconds (separated by a point) and time is adjusted in 10-second steps, up to
the maximum value of
9.5
minutes.
E.g.: if the display shows
2.5
, pause time is 2 min. and 50 secs.
2.0
o 1
OUT 1:
Allows output OUT (open collector N.O.) to be activated in one of the following functions:
00
= Always active
01
= FAIL-SAFE
02
= WARNING LIGHT (off when closed, on during opening and open/pause, flashing during closing)
03
= COURTESY LIGHT (see next function)
04
= ALARM, BATTERY operation
05
= gate OPEN or PAUSED
06
= gate CLOSED
07
= gate in MOTION
08
= gate OPENING
09
= gate CLOSING
10
= ACTIVE safety
11
= timed output that can be activated by second radio channel (see next function)
12
= output that can be activated by second radio channel (step function)
00
t1
TIMING OF OUT 1 (only if option
03
or
11
is selected at the previous step):
Can be used to adjust timing of output OUT if a timed function was selected
(e.g.
03
or
1 1
) from
1
to
99
minutes in 1 minute steps.
02
Ob
OPEN B / CLOSE / EDGE SAFETY DEVICE:
It is possible to select the use of OPEN B input as partial opening, CLOSE command or EDGE
SAFETY DEVICE.
00
= OPEN B
01
= CLOSE
02
= EDGE SAFETY DEVICE
If you select a function logic that involves the use of the CLOSE command (logic
b
,
bC
,
C
) this function will be preset to
01
and it will not be possible to change it.
00
SP
STOP / EDGE SAFETY DEVICE
It is possible to select the use of STOP input as STOP or EDGE SAFETY DEVICE.
00
= STOP
01
= EDGE SAFETY DEVICE
00
Lc
MOTOR LOCK:
It is possible to select the use of the motor lock during battery operation:
Y
= the motor lock continues to operate regularly even during battery operation
no
= when the system switches to battery operation, the motor lock remains
open.
Y