5.3
PROGRAMMING
To access the programming menu, the display must indicate the gate
closed status (
00
).
To access the programming mode from whichever state the gate is in,
press and release the
RESET
button:
00
appears on the display.
Press button P1 (
ENTER
), for approximately 5 seconds, until the first
parameter
A
appears.
Press button P2 (
UP/DWN
) to modify the value of the parameter.
Press button P1 (
ENTER
) to go to the next parameter.
After 60 seconds of inactivity, the system will automatically exit from
the programming menu saving any changes that were made.
parameter default
A
OPEN B input configuration
0
partial opening only
1
closes only (
CLOSE
)
0
b
Failsafe
0
not
enabled
1
enabled
0
c
Automatic closing
0
not
enabled
1
enabled, pause 5 s
2
enabled, pause 10 s
3
enabled, pause 15 s
4
enabled, pause 20 s
5
enabled, pause 25 s
6
enabled, pause 30 s
7
enabled, pause 40 s
8
enabled, pause 80 s
9
enabled, pause 120 s
0
d
OPEN A
operation
0
open/stop/close/open...
1
open/close/open..."
0
E
Partial opening time
0
3
s
1
5
s
2
8
s
3
10
s
0
H
Condominium function
0
not enabled (the
OPEN A
command is operative during
opening)
1
enabled
(the
OPEN
command is ignored during opening)
0
L.
Maximum opening speed
0
10
m/min
1
20
m/min
2
30
m/min
3
40
m/min
0
.L
Maximum closing speed
0
10
m/min
1
20
m/min
2
30
m/min
3
40
m/min
0
o
Immediate closure after transit across photocells
0
not enabled (with automatic closing enabled, the gate always
closes after the pause time)
1
enabled (with automatic closing enabled, the gate closes
immediately after transit across the closing photocells)
0
parameter default
P
Timer function
0
not
enabled
1
enabled
(the
OPEN A
maintained action control keeps the gate
open until released)
1
U
Dead-man function
0
not
enabled
1
enabled (requires the
OPEN
A and
CLOSE
maintained action
controls to be used)
!
In the dead-man mode:
- The control must be activated intentionally and the
gate must be visible
- The OPEN input is disabled.
- If the SAFE input is activated during opening or
closing, it stops the movement immediately.
- If the FSW CL input is activated during closing, it
stops the movement.
- If the FSW OP input is activated during opening, it
stops the movement.
- the speed of the gate must be less than 5 m/min
0
Y
Pre-flashing during closing
0
not
enabled
1
1
s
2
2
s
3
3
s
4
4
s
0
The display, other than when in the programming menu, provides
information regarding the status of the automation (§ 7.2).