17
ENGLISH
Perform the SET-UP as follows:
1.
Enter BASIC programming and go to the parameter
tL
, when F is released
--
will appear.
2.
Ensure that the gate leaves are closed. Otherwise, proceed as follows:
- Press and hold -/R2 to close leaf 2
- Press and hold +/R1 to close leaf 1
Should pr/R1 and/or -/R2 command opening of the corresponding leaf, cut off power and, on terminal board J11 or J12, invert
the cables of the corresponding motor.
3.
With the gate leaves closed, launch SETUP by pressing and holding
+
and
-
until
S1
begins to flash on the display (about 3 sec).
4.
Release
+
e
-
. Leaf 1 begins its opening movement.
Operation WITHOUT Safecoder
Leaf 1 automatically acknowledges the mechanical stop.
Operation WITH Safecoder or S800H ENC
Leaf 1 automatically acknowledges the mechanical stop. It will in
any case be possible to stop leaf movement at any time and in the
desired point by sending an OPEN A pulse.
5.
On the display
S2
will flash (only if 2 motors have been selected): leaf 2 begins opening.
Operation WITHOUT Safecoder
Leaf 2 automatically acknowledges the mechanical stop.
Operation WITH Safecoder or S800H ENC
Leaf 2 automatically acknowledges the mechanical stop. It will in
any case be possible to stop leaf movement at any time and in the
desired point by sending an OPEN A pulse.
Steps 4 and 5 with function
FA
:
FA
=
01
(the limit switch determines the stopping of motion) the OPEN A pulse for stopping motion is ignored.
FA
=
02
(the limit switch determines the start of deceleration) with
Safecoder
installed or operator
S800H ENC
send an OPEN A pulse
only after involving the opening limit switch, without
Safecoder
or with operators different than
S800H ENC
, make sure that the limit
switch is engaged before the mechanical stop.
6.
On the display
S3
will flash (only if 2 motors have been selected): leaf 2 begins closing.
Operation WITHOUT Safecoder
Leaf 2 automatically acknowledges the mechanical stop.
Operation WITH Safecoder or S800H ENC
Leaf 2 automatically acknowledges the mechanical stop. It
will in any case be possible to stop leaf movement at any
time and in the desired point by sending an OPEN A pulse.
7. On the display
S4
flashes: leaf 1 begins closing.
Operation WITHOUT Safecoder
Leaf 1 automatically acknowledges the mechanical stop
Operation WITH Safecoder or S800H ENC
Leaf 1 automatically acknowledges the mechanical stop. It will in
any case be possible to stop leaf movement at any time and in the
desired point by sending an OPEN A pulse.
Steps 6 and 7 with function
FC
:
FC
=
01
(the limit switch determines the stopping of motion) the OPEN A pulse for stopping motion is ignored.
FC
=
02
(the limit switch determines the start of deceleration) with
Safecoder
installed or operator
S800H ENC
send an OPEN A
pulse only after involving the closing limit switch, without
Safecoder
or with operators different than
S800H ENC
, make sure that the
limit switch is engaged before the mechanical stop
8.
S5
flashes on the display: both leaves open at full speed.
9.
S6
flashes on the display: both leaves close at full speed.
10.
The board will automatically exit the programming menu and will display the automated system status (
00
) to confirm that the SETUP
procedure has been completed correctly. If the procedure is not completed correctly, on the display
S0
will start flashing, indicating that a
new SETUP procedure must be performed.
The deceleration spaces can be configured and modified
from the display using the parameters
r1
and
r2
(see
Advanced Programming) without repeating the SETUP.
TESTING THE AUTOMATED SYSTEM
Once installation and programming is completed, ensure that the
system is operating correctly.
Be especially careful that the safety devices operate correctly and
ensure that the system complies with all current safety regulations.