12
ENGLISH
Display
Advanced Function
cF
0
1 2 4 3
6
5
r2
LEAF 2 DECELERATION (visualised only with the function
Mn
=
2
):
You can adjust the deceleration space as a percentage of the total travel
of leaf 2.
Adjustable from
00
to
99
%, in 1% steps.
00
= no deceleration
01
= minimum deceleration space
99
= maximum deceleration space
30
30
20
30
PF
PRE-FLASHING:
You can enable/disable the pre-flashing. Pre-flashing duration = 3 sec.
You can choose:
no
= disabled
OC
= pre-flashing before each movement
CL
= pre-flashing before a closing movement
OP
= pre-flashing before an opening movement
PA
= pre-flashing only at the end of the pause time
no
no
no
no
Ph
CLOSING PHOTOCELLS
:
The intervention of closing photocells causes the reversing of automated
system (opening).
You can choose:
Y
= operate the reversal only after the photocells are released
no
= operate the reversal immediately
no
no
no
no
Ad
ADMAP FUNCTION
:
Allows operation in compliance with French regulation NFP 25/362.
Y
=
enabled
no
= disabled
no
no
no
no
EC
ANTI-CRUSHING SENSITIVITY:
Varying this function varies the amount of time after which, in case of
obstacle, the board commands reversal of the leaves, or it will command
a stop if the leaves are in the contact point search space (see the pa-
rameter
rB
).
The fourth consecutive obstacle detected in the same direction and posi-
tion will be defined as a contact point and the leaf will stop in that position.
0 1
= minimum sensitivity (maximum time before reversal)
10
= maximum sensitivity (minimum time before reversal)
0 1
06
05
05
US
ULTRA-SENSITIVITY:
This function activates an obstacle detection system, based on the
control of the variation of the current absorbed by the motor, causing
immediate leaf reversal.
Y
=
active
no
=
excluded
no
no
Y
Y
rB
MECHANICAL STOP SEARCH ANGLE
(NOT displayed if function
FC
or
FA
=
01
)
:
You can adjust the contact point search angle within which the board
will stop movement without reversing, if it encounters an obstacle or the
contact point.
Adjustable from
0.3
to
20
degrees.
From
0.3
to
9.9
degrees, adjustments are made in 0.1 degree steps.
From
10
to
20
degrees, adjustments are made in 1 degree steps.
10
10
4.0
4.0