9
ENGLISH
Display
Basic Function
cF
0
1 2 4 3
6
5
En
ENCODER USE:
You can enable/disable the use of encoders
(both BUS and GATECODER
encoders)
:
Y
= encoders on both motors
no
= encoders disabled
When using configurations
3
,
5
or
6
it is mandatory to
use the encoder,
no
is not selectable
no
no
Y
Y
FA
LIMIT SWITCH WHEN OPENING:
Lets you set or disable use of the opening limit switch on swing-leaves.
no
= opening limit switches disabled
01
= the limit switch determines the stopping of motion
02
= the limit switch determines the start of deceleration
After having changed the value of this function, SETUP is
required: the card will signal error
14
(configuration error)
until the SETUP is performed again or until the previous
value is restored
no
no
no
no
FC
LIMIT SWITCH WHEN CLOSING:
Lets you set or disable use of the closing limit switch on swing-leaves.
no
= closing limit switches disabled
0 1
= the limit switch determines the stopping of motion
02
= the limit switch determines the start of deceleration
After having changed the value of this function, SETUP is
required: the card will signal error
14
(configuration error)
until the SETUP is performed again or until the previous
value is restored.
no
no
no
no
Cd
DELAY FOR CLOSING LEAF (visualised only with the function
Mn
=
2
):
Is the delay time for starting leaf 1 closing with respect to leaf 2. Makes
it possible to avoid overlapping of the two leaves.
Adjustable from
00
to
59
sec, in 1- second steps.
Next the value 59, the viewing changes to minutes and tenths of a second
(separated by a decimal point) and time is adjusted in 10-second steps
up to the maximum value of
3
minutes
.
e.g.: if the display shows
1.2
, the time is 1 min and 20 sec
05
05
05
05
bu
BUS-2EASY
DEVICES ENTRY:
See the related paragraph.
no
no
no
no