Key Components of E124 Board
Description of Key Components
LCD
SIGNALS AND PROGRAMMING DISPLAY
DL8
“FCA2” STATUS LED -LIMIT SWITCH OPEN – IF GATE CLOSED ON
SW4
“+” PROGRAMMING BUTTON
DL9
“FCC2” STATUS LED -LIMIT SWITCH CLOSED – IF GATE CLOSED OFF
SW5
“-” PROGRAMMING BUTTON
DL12
LED FOR BUS-2EASY DEVICE ACTIVE
SW6
“F” PROGRAMMING BUTTON
DL13
LED FOR BUS-2EASY DIAGNOSTICS
SW7
“RESET SW” SOFTWARE RESET BUTTON
DL14
LED SIGNALING PRIMARY POWER ON
DL1
“IN1” STATUS LED – DEFAULT OPEN A - NORMAL STATE OFF
DL19
LED FOR WHEN “SW7” IS PRESSED
DL2
“IN2” STATUS LED – DEFAULT OPEN B - NORMAL STATE OFF
DL20
LED SIGNALLING “ALARM”
DL3
“IN3” STATUS LED – DEFAULT STOP - NORMAL STATE ON
J3
CONNECTOR FOR CONNECTION OF BUS-2EASY DEVICES
DL4
“IN4” STATUS LED – DEFAULT FSW OP - NORMAL STATE ON
J4
CONNECTOR FOR TERMINAL BOARD INPUTS
DL5
“IN5” STATUS LED – DEFAULT FSW CL - NORMAL STATE ON
J5
CONNECTOR FOR OUTPUT 2 (OUT2)
DL6
“FCA1” STATUS LED -LIMIT SWITCH OPEN – IF GATE CLOSED ON
J6
CONNECTOR FOR TRAVEL LIMITS
DL7
“FCC2” STATUS LED -LIMIT SWITCH CLOSED – IF GATE CLOSED OFF
Electrical Connections
Connection of Traditional Photocells
The E124 Control Board allows for the use of traditional photocells (n/c with relay). Below is a layout drawing showing the
basic positions normally covered. The wiring diagram is for Fail-Safe enabled photocells. In order to comply with the standards,
all devices used for safety should either have a circuit monitored by the control board or be self-monitoring. FAAC Control
boards are able to perform the monitoring by the use of a Fail-Safe function, whereby the test negative is momentarily dropped
(please note that this may not be compatible with non-FAAC equipment). This function is enabled by entering Advanced
Programming (detailed below) and setting function
o1 to 01
.
8
8
6
6
7
5
6
4