ENGLISH
CYCLE COUNTER
READING THE CYCLES PERFORMED COUNTER
Add together the readings of functions
nc
(thou-
sands) and
nd
(tens) in ADVANCED programming.
RESETTING THE CYCLE COUNTER
In ADVANCED programming, with the function
AS
=
no
, go to function
nc
and press
++
and
--
for 5 s
.
MAINTENANCE REQUESTED
It is possible to program the number of cycles after
which maintenance is required.
When the automation reaches the set number of
cycles, there is a pre-flashing of at least 8 s at each
movement. The user should ask the installer to carry
out maintenance.
1. In ADVANCED programming, function
AS
, se-
lect
Y
to enable the maintenance request.
2. In function
nc
set the value in thousands using
the
++
and
--
buttons.
3. In function
nd
set the value in tens using the
++
and
--
buttons.
4. Exit and save the programming.
9.2 RESTORING FACTORY SETTINGS
The procedure:
-
restores all the default settings of the board
-
deletes the SETUP
-
deletes all the radio controls
-
resets the cycle counter
1. With the board not powered, switch on mains
power (the MAIN LED lights up).
2. A few seconds after having been switched on,
while the display shows the FW version (e.g.
4.0
), press and hold down the buttons
++
,
--
,
FF
simultaneously.
-
After approximately 10 s,
--
appears on the
display and LEDS
R1
and
R2
light up.
3. Release the buttons.
-
LEDs
R1
and
R2
switch off.
-
After approximately 10 s,
S0
flashes on the display