![FAAC E124 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/faac/e124/e124_original-instructions-manual_3115894031.webp)
1 9
E124 29
532365 - Rev.A
OPEN A
OPEN B
- +
-
RADIO
CLOCK BATTERY
BATTERY
RESET
SETUP
R2
R1
PRGRM
LCD1
POWER
SUPPLY
USB
F
XF MODULE
+
8.8.
1 2
1 2 1 2
3 4 5 6 7 8
11 12 13 14 15 16 17 18 19 20
DL1 DL2 DL3 DL4
DL9 DL10 DL11
DL12
SW3
DL14
BATTERY
SW1
SW2
DL13
DL5
DL6 DL7 DL8
ALARM
RESET
DL12
DL1 DL2 DL3DL4
DL6
DL7DL8
DL9
DL5
DL13
DL10 DL11
2EASY
OUT2
OUT1
LAMP LOCK MOT1 MOT2
+
-
+
-
IN1
IN2
IN4
IN5
GND
IN3
GND
+24
FCA
1
FCC
1
FCC
2
FCA
2
GND
GND
GND
ENC
1
+24
ENC
2
LED
R1
- +
-
RADIO
CLOCK BATTERY
BATTERY
RESET
SETUP
R2
R1
PRGRM
LCD1
POWER
SUPPLY
USB
F
XF MODULE
+
8.8.
1 2
1 2 1 2
3 4 5 6 7 8
11 12 13 14 15 16 17 18 19 20
DL1 DL2 DL3 DL4
DL9 DL10 DL11
DL12
SW3
DL14
BATTERY
SW1
SW2
DL13
DL5
DL6 DL7 DL8
ALARM
RESET
DL12
DL1 DL2 DL3DL4
DL6
DL7DL8
DL9
DL5
DL13
DL10 DL11
2EASY
OUT2
OUT1
LAMP LOCK MOT1 MOT2
+
-
+
-
IN1
IN2
IN4
IN5
GND
IN3
GND
+24
FCA
1
FCC
1
FCC
2
FCA
2
GND
GND
GND
ENC
1
+24
ENC
2
LED
R2
RC
P2
RC
P1
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
7.5 RADIO CONTROLS - RC/LC
MEMORISING THE RADIO CONTROLS ON THE
BOARD
This memorisation procedure applies to the integrated OmniDEC
receiver combined with the 3-pin plug in module (it allows OPEN A
and OPEN B commands to be memorised).
If a 5-pin plug in receiver is used (only for OPEN A command), follow
the specific instructions.
MEMORISING OPEN A
1. Press the
++
(or
R1
) button on the board and release
it when
Led R1
starts to flash, for 20 s (time available
for the next step).
2. Press and release button
P1
on the radio con-
trol.
The command is executed immediately
and
LED R1
on the board becomes steady for 2 s (memorisation
completed), then starts to flash again. Another
radio control can be memorised within 20 s.
The procedure ends after 20 s when
LED R1
switches
off. To add additional radio controls, repeat the pro-
cedure from step 1.
MEMORISING OPEN B
Proceed as for memorising OPEN A, using the
--
(or
R2
) button combined with
LED R2
and button
P2
on
the board.
ADDING RADIO CONTROLS
Use a LC/RC radio control that is already use by the automation,
without having to use the board.
OPEN A COMMAND
1. Take a radio control that is already in use, on one of
the two (OPEN A or OPEN B) channels and move
close to the board.
2. Press buttons
P1
and
P2
simultaneously on the radio
control that is already in use and release them when
the
LED
starts to flash slowly for 5 s (time available
for the next step).
3. Press and hold down button
P1
and check the
LED
on the board:
starts to flash, for 20 s (time available
for the next step).
4. Press button
P1
on the new radio control. Check
LED
R1
on the board:
it becomes steady for 2 s (memo-
risation complete), then starts to flash again and it
is possible to memorise OPEN A on the new radio
control within 20 s.
The procedure ends after 20 s when the
LED
on the
board switches off. To add additional radio controls,
repeat the procedure from step 1.
OPEN B COMMAND
Proceed as for OPEN A, using button
P2
on the radio
control at steps 2 and 3 and checking
LED R2
on the
board.
Содержание E124
Страница 1: ...E124 Translation of the original instructions...
Страница 43: ......