E045S
14
532373 - Rev.A
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
Function
default
rB
SEARCH FOR STOP
(displayed only if
En
=
Y
)
This function specifies the angular space in which
to search for the opening/closing stop. In this
space, the automation is stopped by a mechanical
stop/obstacle and not by the anti-crushing system.
00
~1°
02
~4°
02
Sp
PROGRAMMING OUTPUT W.L.
00
LED function
06
automation closed warning
00
tA
ADDITIONAL OPERATING TIME
(displayed only if
En
=
no
)
Adds additional operating time at the end of the
movement.
00
…
30
(Adjustment step: 1 s)
03
St
LEAVING THE PROGRAMMING MODE
Y
exit saving the settings
no
exit without saving the settings
After having confirmed using button
FF
, the display
indicates the STATUS of the automation:
Y
00
CLOSED
06
CLOSING
01
OPEN
07
FAILSAFE IN PROGRESS
02
STATIONARY THEN OPENS
08
CHECK Bus 2easy
03
STATIONARY THEN CLOSES
09
PREFL ASHING BEFORE
OPENING
04
IN PAUSE
10
PREFL ASHING BEFORE
CLOSING
05
OPENING
6.3 OPERATING LOGICS
i
the STOP command has priority in all the logics and
stops the automation.
The CLOSE command always closes the automation.
■
E
SEMI-AUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening, stops the gate and the next
OPEN command closes it.
OPEN during closing, causes it to reopen.
The triggering of the photocells: during movement,
reverses the gate.
■
EP
SEMI-AUTOMATIC STEP-BY-STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to open.
OPEN if the automation is open, causes it to close.
OPEN during opening or closing, stops the gate and
the next OPEN command reverses the direction.
The triggering of the photocells: during movement,
reverses the gate.
■
SP
AUTOMATIC STEP BY STEP
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during pause, causes it to close.
OPEN during opening or closing, stops it and the
next OPEN command reverses the direction.
The triggering of the closing photocells: during
pause, closes the gate - during opening, requests
closing - during closing, causes the gate to open and
then closes it immediately.
■
A
AUTOMATIC
This logic only uses the OPEN command.
OPEN if the automation is closed, causes it to
open. The automation closes automatically after the
pause time has elapsed.
OPEN during the pause, resets the pause time.
OPEN during opening, is ignored.
OPEN during closing, causes it to reopen.
The triggering of the closing photocells: during pause,
reloads the pause time.