1)  ATTENTION! To ensure the safety of people, it is important that you read 

all the following instructions. Incorrect installation or  incorrect use of the 
product could cause serious harm to people.

  2)  Carefully read the instructions before beginning to install the product.
  3)  Do not  leave packing materials (plastic, polystyrene, etc.)   within  reach 

of  children as  such materials  are  potential  sources  of  danger.

  4)  Store these instructions for  future reference.
  5)  This product was designed and built strictly for the use indicated in this 

documentation. Any other use, not expressly indicated here, could 
compromise the good condition/operation of the product and/or be 
a source of danger.

  6)  FAAC declines all liability caused by improper use or use other than that 

for which the automated system was intended.

  7)  Do not install the equipment in an explosive atmosphere: the presence 

of  inflammable gas or fumes is a serious danger to safety.

 8) T h e   m e c h a n i c a l   p a r t s   m u s t   c o n f o r m   t o   t h e 

p r o v i s i o n s   o f   S t a n d a r d s   E N   1 2 6 0 4   a n d   E N   1 2 6 0 5 .
For non-EU countries, to obtain an adequate level of safety, the 
Standards mentioned above must be observed, in addition to national 
legal regulations.

  9)  FAAC is not responsible for failure to observe Good Technique in 

the construction of the closing elements to be motorised, or for any 
deformation that may occur during use.

 10)  The installation must conform to Standards EN 12453 and EN 12445.
 

  For non-EU countries, to obtain an adequate level of safety, the Standards 

mentioned above must be observed, in addition to national legal 
regulations. 

 11)  Before attempting any job on the system, cut out electrical power.
 12)  The mains power  supply of the automated system must be fitted with an 

all-pole  switch with contact opening distance of 3 mm or greater. Use 
of a 6A thermal breaker with all-pole circuit break is recommended.

 13)  Make sure that a differential switch with threshold of 0.03 A is fitted 

upstream of the system.

 14)  Make sure that the earthing system is perfectly constructed and connect 

metal parts of the closure to it. 

 15)  The safety devices (EN 12978 standard)  protect any danger areas 

against 

mechanical movement Risks

, such as crushing, dragging, and 

shearing.

 16)  Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended 

for every system, as well as a warning sign adequately secured to the 
frame structure, in addition to the devices mentioned at point “15”.

 17)  FAAC declines all liability as concerns safety and efficient operation of 

the automated system, if system components not produced by FAAC 
are used.

 18)  For maintenance, strictly use original parts by FAAC.
 19)  Do  not in any way modify the components of the automated 

system.

 20)  The installer shall supply all information concerning manual operation 

of the system in case of an emergency and shall hand over to the user 
the warnings handbook supplied with the product.

 21)  Do not allow children or adults to stay near the product while it is 

operating.

 22)  Keep remote controls or other pulse generators away from children, to 

prevent the automated system from being activated involuntarily.

 23)  Transit is permitted only when the automated system is idle.
 24)  The user must not attempt any kind of repair or direct action whatever 

and contact qualified personnel only.

 25)  Check at least every 6 months the efficiency of the system, particularly 

the efficiency of the safety devices (including, where foreseen, the 
operator thrust force) and of the release devices.

 26)  Anything not expressly specified in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

CE DECLARATION OF CONFORMITY FOR MACHINES

(2006/42/EC DIRECTIVE)

Manufacturer: 

FAAC S.p.A.

Address:

 

Via Calari, 10 - 40069  Zola Predosa BOLOGNA - ITALY

Declares that: 

The operator mod. D700HS with E700HS board,

 

• is built to be incorporated in a machinery or to be assembled with other machines to form a machine 

 

   according to 2006/42/EC Directive;

 

•  complies with the essential safety requirements of the following EC directives:

 - 

2004/108/EC.

 - 

 

2006/95/EC.

 

  furthermore the manufacturer declares that the machinery cannot be put into service until the machine into 

which it will be integrated or of which it will become a component has been identified and it complies with the 

conditions of 2006/42/EC Directive and subsequent modifications assimilated in the Italian National legislation 

under Presidential Decree No. 17 of 27 January 2010.

 

Bologna, 01 February 2010

 

 

 

    The 

Managing 

Director

                                    A. Marcellan

Содержание D700HS

Страница 1: ...D700HS...

Страница 2: ...s and components of board E700HS p 6 8 2 Terminal boards and connectors p 7 8 3 DS1 Programming dip switches p 7 8 4 Operating logics p 7 9 COURTESY LAMP p 8 10 CONNECTIONS p 8 11 PROGRAMMING p 8 11 1...

Страница 3: ...anical closures of the door so that it is the automated system that blocks the door when closed apply the warning stickers according to the instructions install manual release devices at a height not...

Страница 4: ...er areas against mechanical movement Risks such as crushing dragging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequat...

Страница 5: ...rinsic safety device Class 2 Sectional door max width mm 5000 Sectional door max height mm See useful travel Sliding guide useful travel mm 2000 2600 3200 3800 Protection class Only for internal use I...

Страница 6: ...before starting with the installation 1 Release the carriage see par 7 4 point 3 and take it to the slot on the upper part of the sliding guide 2 Fit the terminal of the small cable into its relevant...

Страница 7: ...ght of 180 cm off the ground then cut the rope in excess 2 Make a knot at the end of the rope and assemble the release handle Fig 23 3 Pull downwards the release handle and check if the door can be mo...

Страница 8: ...ntrol device with NO contact see chapter OPERATING LOGICS STOP Device with NC contact that causes the block of the automated system Negative for OPEN A and STOP devices FSW Closing safety device with...

Страница 9: ...at opening and closing in the automatic mode instead the control board autonomously determines the movement parameters If the procedure is not completed correctly i e due to excessive friction during...

Страница 10: ...ing the normal operation of the automated system AUTOMATIC LEARNING WITH LOGIC A AUTOMATIC NOTA we recommend you to perform this learning at LOW speed dip switch 4 ON Hold down the SET UP push button...

Страница 11: ...radio control to add observing the following procedure On the memory stored radio control press and hold down the push buttons P1 and P2 simultaneously The LED of the radio control begins to flash Rel...

Страница 12: ...of the lock release operations of the operator as shown in the mentioned guide 14 FALL PREVENTION CABLES Connect the fall prevention cables to the rear door and to the ceiling fitting Fig 32 15 MAINTE...

Страница 13: ...s signalling a fault Theautomatedsystemperformsfrequent reversals of movement during the opening and or closing movement The automated system detects an excessive difficult movement of the door If you...

Страница 14: ...2000 2600 3200 3800 1 2 3 Inserto Immagini Pictures Collection Inserto Immagini Pictures Collection Collection de Figure Cojunto de Imagenes Collection de Figure Cojunto de Imagenes Photo Kollektion...

Страница 15: ...8 5 6 7 4...

Страница 16: ...15 14 13 12 11 10 A B C 9...

Страница 17: ...23 22 21 20 15 20 19 18 17 16...

Страница 18: ...28 OPEN A ALTRE SICUREZZE STOP 27 26 25 24 A C B...

Страница 19: ...35 34 31 32 33 30 OPEN B OPEN A RADIO SET UP 29...

Страница 20: ...43 2 sec 5 sec 42 41 8 sec 40 1 sec 38 39 2 sec 5 sec 37 8 sec 36 1 sec...

Страница 21: ...50 49 51 4 sec 2 sec 5 sec 48 5 sec 47 2 sec 5 sec 46 44 45 5 sec 4 sec...

Страница 22: ...ansmission chain or belt pulls the door open to allow access If the automatic mode was set the door closes automatically after pause time has elapsed An opening pulse given during the opening stage ha...

Страница 23: ...chnician Customer 9 Technician Customer 10 Technician Customer Installer Customer Type of system Serial No Installation date Start up PART MODEL SERIAL NUMBER Operator Safety device 1 Safety device 2...

Страница 24: ...en conservant les caract ristiques essentielles sans devoir pour autant mettre jour cette publication Die Beschreibungen und Abbildungen in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich da...

Отзывы: