SPEED CHANGES
There are 10 speed adjustment levels for opening and closing.
Level 10 refers to the maximum speed permitted by door weight,
whereas level 1 refers to the corresponding minimum speed.
The OPENING and CLOSING speeds can be adjusted directly on
the board (entering programming).
no effect
no effect
restarts pause time
count
total opening and
re-closing after pause
time
restarts pause time
count
partial opening and
re-closing after pause
time
restarts pause time
count
total opening and
re-closing after pause
time
restarts pause time
count
partial opening and
re-closing after pause
time
no effect
no effect
no effect
no effect
restarts pause time
count
total opening and
re-closing after pause
time
restarts pause time
count
partial opening and
re-closing after pause
time
no effect
no effect
no effect
no effect
no effect
no effect
no effect
starts night pause time
count
total opening and
re-closing after night
pause time
starts night pause time
count
partial opening and
re-closing after night
pause time
starts night pause time
count
total opening and
re-closing after night
pause time
starts night pause time
count
partial opening and
re-closing after night
pause time
total opening and
re-closing after night
pause time
partial opening and
re-closing after night
pause time
no effect
no effect
starts pause time count
total opening
total opening
total opening
starts pause time count
total opening
total opening
total opening
total opening
total opening
no effect
immediate closing
immediate closing
no effect
immediate closing
no effect
immediate closing
no effect
immediate closing
no effect
no effect
no effect
IN ANY POSITION
OPEN
OPEN
CLOSED
PARTIALLY OPEN
CLOSED
OPEN
CLOSED
PARTIALLY OPEN
CLOSED
CLOSED
CLOSED
MANUAL
TOTALLY OPEN
TOTAL
AUTOMATIC
TWO-WAY
PARTIAL
AUTOMATIC
TWO-WAY
TOTAL
AUTOMATIC
ONE WAY
PARTIAL
AUTOMATIC
ONE WAY
TOTAL NIGHT
PARTIAL NIGHT
INTERNAL SENSOR
(I-DET)
EXTERNAL SENSOR
(E-DET)
KEY
EMERGENCY OPENING
(EMERG 2) (1)
EMERGENCY CLOSING
(1)
DOOR STATUS
OPERATING FUNCTION
BEHAVIOUR UNDER DIFFERENT OPERATING FUNCTIONS
This is the default configuration:
Emerg1 ---> Stop/no memory
A pulse (function not shown in the table) causes immediate stop
followed by slow re-closing after pause time (night pause time if
the Night operating function was set).
Emerg2 ---> Emergency opening/no memory:
A pulse causes opening followed by re-closing after pause
time.
Emergency commands have priority over all others.
no effect
(1) Emerg1 and Emerg 2 inputs can be programmed with
SD- Display to obtain:
• emergency opening;
• emergency closing;
• stop.
Furthermore, command activation can be programmed:
• with no memory (when the command is de-activated, the
door resumes normal operation);
• with memory (when the command is de-activated, a Reset
is necessary to restore normal operation).