Terminal-board J4
1 TX1
Connection to transmitter of 1st pair of button photocells
2 TX
GND
Negative connection for button photocells transmitters
3 TX2
Connection to transmitter of 2nd pair of button photocells.
4 RX1
Connection to receiver of 1st pair of button photocells.
5 RX
GND
Negative connection for button photocells receivers
6 RX2
Connection to receiver of 2nd pair of button photocells.
The following configurations are possible if using button
photocells: (Ref.
DIP-SWITCH PROGRAMMING)
NO PHOTOCELL
• Position dip-switches 1 and 2 of DS1 to OFF.
• Leave the relevant inputs free on J4
1 PHOTOCELL
• Position dip-switch 1 or 2 to ON in according to input used
and other dip-switch to OFF.
• Leave inputs not used free on J4 .
2 PHOTOCELL
• Position dip-switches 1 and 2 of DS1 to ON.
• Connect the photocells as shown in the lay-outs
For extra-European countries where the EN16005 standard is not in force, it is possible to continue
using photocells and traditional sensors.
Warning : photocells are not permitted as a safety device in the countries of the European community
where the EN16005 standard is in force Specifically, photocells are considered as auxiliary devices, com-
plementary to safety. Below are the connections on automatic door board:
Connection terminal J4
J4
PHOTOCELLS
TX1
TX2
RX2
RX1
+ RX2
GND
+ RX1
+ TX2
GND
+ TX1
J4
PHOTOCELLS
TX1
RX1
+ RX2
GND
+ RX1
+ TX2
GND
+ TX1
If you are not using any pair of photocells, leave the inputs of connector J4 free
.
The button photocells are constantly monitored by the electronic control board of the door. The board controls correct ope-
ration of the door at every movement.
CONNECTION OF BUTTON PHOTOCELLS
1 pair of photocells
2 pairs of photocells
The colours of the button photocell (heads) cables are:
receiver
black/blue
transmitter
grey/blue
The colours of the button photocells sheaths are:
receiver
black
transmitter
grey
black
blue
grey
blue
grey
black
black
blue
grey
blue
grey
black
black
blue
grey
blue
grey
black