33
Fig. 50
Fig. 49
Fig. 48
9. RESTORING NORMAL OPERATION
To prevent an involuntary pulse from activating the gate during the
manoeuvre, cut power to the system before re-locking the operator.
1)
Re-close the release lever.
2)
Turn the key anti-clockwise
3)
Remove the key and close the lock protection door.
4)
Move the gate until the release meshes.
8. MANUAL OPERATION
If the gate has to be operated manually due to a power cut
or malfunction of the automated system, use the release
device as follows:
1)
Open the protection door and fit the supplied key in the
lock (Fig. 48).
2)
Turn the key clockwise and pull the release lever as shown
in Fig. 49.
3)
Open and close the gate manually.
10. INSTALLING THE CN 60E CONTROL UNIT (OPTIONAL)
The operator is designed to house (with the aid of a DIN bar)
the CN 60E control unit of the safety conductive edge. Cut the
DIN bar to measure and secure it to the operator with two
screws in the appropriate holes and attach the CN 60E control
unit to it (Fig. 50).
For connection and operation, refer to the specific instructions.
Fig. 52
Fig. 51
11.
INSTALLING REMOTE BOARD 578D
If you prefer to install the control board separately from the
operator, you must use remote board 578D. In this case, an
interface card is fitted on board the operator (fig. 51).
For connections from the interface card to the remote board,
please refer to the specific instructions on the 578D board.
12.
INSTALLING BOARD 462DF
If you wish to install the 462DF control board on the operator,
you must use the appropriate adapter kit (Fig. 52).
To install it, refer to the specific instructions.
13.SPECIAL APPLICATIONS
There are no special applications.
interface card
Fig. 47