20
ENGLISH
ENGLISH
Fig. 31
5.3.
DIPSWITCH SETTINGS
To program the operation of the automation, set the dipswitches
as shown in the diagram above.
Ü
Press the RESET button after all programming operations.
(1) With the pre-flashing selected, movement starts after 5 seconds.
(2) If the impulse is sent during pre-flashing, the timer is reset to zero.
5.4.
FAULT CONDITIONS
The following conditions effect normal operation of the
automation:
a
microprocessor error
b
intervention of the electronic safety timer (interruption of
operation after continuous working time exceeds 255
seconds).
c
disconnection of the limit switch cable connector
•
Conditions
a
and
b
have the sole effect of causing the
automation to stop.
•
Condition
c
causes an alarm condition inhibiting all
operation:
normal operation is only resumed after the cause of
the alarm has been eliminated and the RESET button
has been pressed (or the power supply has been
momentarily interrupted).
To signal this condition, the warning light must be connected:
an alarm condition is signalled by rapid flashing (0.25 sec) of
the warning light.
5.5.
POSITIONING THE TRAVEL STOP PLATE
The 746 operator is fitted with an inductive proximity limit switch
(Fig.1 - ref.3). When the latter detects the passage of a plate
fastened to the top of the rack, it stops the movement of the
gate.
To position the two travel stop plates correctly, proceed as
follows:
1)
Connect the limit switch connector to the 746MPS control
unit in accordance with the direction of gate closure
(paragraph 5.2.3. and Figs. 28/29).
2)
Assemble the limit switch, positioning the stop plate cen-
trally relative to the threaded studs of the bracket (Fig.32).
3)
Switch on the power supply.
4)
Move the gate by hand towards it closed position, stop-
ping approximately 2 cm from the physical travel stop.
5)
Set brake-adjusting trimmer TR1 approximately to its cen-
tral position (Fig.23 - ref.TR1).
TABLE 5
LOGIC A1 (AUTOMATIC)
Operating logics
There are four operating logics available:
A1
= Automatic
A2
= Automatic Plus
E1
= Semi-automatic
E2
= Semi-automatic Plus
Operation of the different logics is described in tables 5-6-7-8.
Pause time
The pause time is amount of time the gate remains open
before it recloses when an automatic control logic is selected.
Pause times include the pre-flashing time, if selected.
Pre-flashing
It is possible to select 5 seconds pre-flashing of the flashing light
before any gate movement. This serves to warn any persons in
the vicinity that the gate is about to start moving.
1
2
3
4
5
Pre-flashing
SW5
Yes
ON
No
OFF
Logic
SW1
SW2
E1
ON
ON
A1
OFF
ON
E2
ON
OFF
A2
OFF
OFF
Pause time
(sec)
SW3 SW4
5
ON
ON
10
OFF ON
30
ON OFF
120
OFF OFF
ON
OFF
TABLE 6
LOGIC E1 (SEMI-AUTOMATIC)
TABLE 7
LOGIC A2 (AUTOMATIC PLUS)
TABLE 8
LOGIC E2 (SEMI-AUTOMATIC PLUS)
LOGIC A1
IMPULSES
GATE STATUS
OPEN
STOP
SAFETY
CLOSED
opens and recloses
after pause time (1)
no effect
no effect
OPEN
recloses
after 5" (2)
stops counting
freezes pause untill
disengagement
CLOSING
inverts motion
stops
inverts motion
OPENING
no effect
stops
no effect
STOPPED
recloses
immediately (1)
no effect
no effect
LOG IC E1
IM PULSES
GATE STATUS
OPEN
STOP
SAFETY
CLOSED
opens (1)
no effect
no effect
OPEN
recloses (1)
no effect
no effect
CLOSING
inverts motion
stops
inverts motion
OPENING
stops
stops
no effect
STOPPED
recloses (reopens
when safety devices
are engaged) (1)
no effect
no effect
LO G IC A 2
IM P U LS ES
G A TE S TA TU S
O P E N
S TO P
S A FE TY
C LO S E D
open and recloses
after pause tim e (1)
no effect
no effect
O P E N
recloses
after 5" (2)
stops counting
on disengagem ent
recloses after 5" (1)
C LO S IN G
inverts m otion
stops
stops and inverts
m otion w hen
disengaged (1)
O P E N IN G
no effect
stops
no effect
S TO P P E D
recloses
im m ediately (1)
no effect
no effect
LO G IC E 2
IM P U LSE S
G A TE STA TU S
O P E N
S TO P
S A FE TY
C LO S E D
opens (1)
no effect
no effect
O P E N
recloses (1)
no effect
no effect
C LO S IN G
invert m otion
stops
stops and inverts
m otion w hen
disengaged (1)
O P E N IN G
stops
stops
no effect
S TO P P ED
recloses (reopens
w hen safety devices
are engaged) (1)
no effect
no effect