23
ENGLISH
Logic “E” Semi-automatic C=0 d=0 E=0
Gate status
Pu
lses
Open A
Open B
Stop
Opening safety devices
Closing safety devices
OP/CL safety devices
Closed
Opens the gate
Executes partial opening
No effect
(OPEN disabled)
Disables
OPEN commands
No effect
Disables
OPEN commands
Open
Closes the gate
Closes the gate
No effect
(OPEN disabled)
No effect
Saves the OPEN
command and closes
at r
elease
Disables
OPEN commands
A
t closure
Re
verses gate movement
No effect
Stops operation
No effect
Reverses gate movement
Stops operation and reverses after r
elease
A
t opening
Re
verses gate movement
No effect
Stops operation
Re
verses gate movement
No effect
stops operation and restarts after r
elease
Logic “EP” Step-by
-Step Semi-automatic C=0 d=1 E=0
Gate status
Pu
lses
Open A
Open B
Stop
Opening safety devices
Closing safety devices
OP/CL safety devices
Closed
Opens the gate
Executes partial opening
No effect
(OPEN disabled)
Disables
OPEN commands
No effect
Disables
OPEN commands
Open
Closes the gate
Closes the gate
No effect
(OPEN disabled)
No effect
Saves the OPEN
command and closes
at r
eleases
Disables
OPEN commands
A
t closure
Stops gate motor and opens after next pulse
No effect
Stops operation
No effect
Reverses gate movement
Stops operation and reverses after r
elease
A
t opening
Stops gate motor and closes after next pulse
No effect
Stops operation
Re
verses gate movement
No effect
stops operation and restarts after r
elease
Logic “D” Condominium C=1 d=0 E=1
Gate status
Pulses
Open A
Open B
Stop
Opening safety devices
Closing safety devices
OP/CL safety devices
Closed
Opens gate and r
ecloses
after pause time
Partially opens the leaf and r
ecloses after pause
time
No effect
(OPEN disabled)
Disables
OPEN commands
No effect
Disables
OPEN commands
Open in pause
P=0
Closes immediately
P=1
Re
loads pause time;
if held down
, it stops gate
movement; on r
elease, it
re
closes after pause time
Recloses the gate
immediately
Stops operation
No effect
O=0
at r
elease, and pr
oviding pause time has
elapsed, r
ecloses after 5 seconds,
otherwise, it
recloses when pause time is up
O=1
at r
elease, if pause time has elapsed, r
ecloses
after 5 seconds,
otherwise it recloses immediately
A
t closure
Re
verses gate movement
No effect
Stops operation
No effect
Reverses gate movement
Stops operation and reverses after r
elease
A
t opening
No effect
No effect
Stops operation
Re
verses gate movement
No effect
stops operation and restarts after r
elease
Содержание 724D