14
ENGLISH
24 Vdc CONTROL UNIT FOR SLIDING GATES
OPERATING INSTRUCTIONS – INSTALLATION INSTRUCTIONS
1. GENERAL CHARACTERISTICS
This 24Vdc control unit for sliding gates offers high performance and a wide range of adjustments, with opening and
closing slow-downs, encoder management and the possibility of managing both opening and closing travel limit
devices.
If correctly installed, thanks to encoder control, this control unit guarantees installation conforming to current safety
regulations.
A sophisticated electronic control monitors the power circuit at all times and disables the control unit in the event of
malfunctions that could impair efficiency of the electronic clutch.
The parameter settings and the operating logics are shown on a handy LCD display, which indicates gate status during
normal operation. Operating times are controlled by self-learning during programming.
In “C” version gearmotors, the control unit is on board the gearmotor. A waterproof enclosure is available for housing
the control unit and any buffer batteries (optional) which must correspond to the indications in the following table.
2. TECHNICAL SPECIFICATIONS
Supply voltage of transformer
230/115 Vac (+6 -10%) - 50/60 Hz.
Supply voltage of control unit
24 Vac (+6 -10%) - 50/60 Hz.
Absorbed power
3 W
Motor max. load
70 W
Accessories max. load
24Vdc 500mA
Flashing lamp/courtesy light max. load
24Vdc 15W max.
Operating ambient temperature
-20°C +50°C
Protection fuses
4 (3 self resetting)
Function logics
Automatic / Step-by-step automatic/Semi-automatic /
Step-by step semi-automatic/Condominium
Opening / closing time
Through self-learning during programming
Pause time
Through self-learning during programming
Thrust force
Four levels adjustable on display
Slow-downs
At opening and closing
Terminal board inputs
24 Vac power supply, Supply to batteries, Encoder, Total
opening, Pedestrian opening, Opening safety devices,
Closing safety devices, Stop, Opening travel limit devices,
Closing travel limit devices
Radio connector
Rapid 5 pin connector for receiver
Terminal board outputs
24Vdc supply for accessories, 24Vdc for motors, Courtesy
light/ Flashing lamp 24 Vdc, Electrical lock 12 Vdc/ac
Board dimensions
145 x 128 mm.
Characteristics of 230Vac toroidal transformer
primary 230Vac sec. 22Vac 120VA
Characteristics of 115Vac toroidal transformer
primary 115Vac sec. 20Vac 120 VA
Characteristics of optional batteries
12V 4Ah dimensions: 90 x 70 x 108 mm
Characteristics of outdoor grade enclosure
306 x 225 x 130 mm. - IP55
Different output values can be obtained on the 24Vac output depending on the mains voltage value. Before
start-up, always check the transformer output voltage. It must not exceed 26Vac for both power feed values of
230Vac and 115Vac. Voltage must be measured load free, i.e. with the transformer powered and disconnected
from the board.
3. PREPARATIONS
To ensure people’s safety, all warnings and instructions in this booklet must be carefully observed. Incorrect
installation or incorrect use of the product could cause serious harm to people.
Keep the instructions for future reference
Make sure there is an adequate differential switch upstream of the system as specified by current laws, and install a
single-pole thermal breaker on the electrical power mains.
To lay cables, use adequate rigid and/or flexible tubes.
Always separate connection cables of low voltage accessories from those supplying 115/230 Vac. To prevent any
interference whatever, use separate sheaths.
If you wish to put the control unit in a remote position with respect to the motor, the maximum length of the
power cables between the control unit and the motor must not exceed 3 m, using cables with a diameter
of 2.5 mm
2
for the motor and 3x0.5 mm
2
for the encoder and the travel limit devices (optionals). One cannot
guarantee correct encoder operation for distances longer than 3 meters.
Procedure for securing components inside the water-tight enclosure, refer to paragraph 15.
Содержание 724D