The 615BPR automated system consists of an aluminium 

beam with reflex reflectors, and a steel upright subjected 

to cataphoresis treatment and painted with polyester paint. 

The upright houses the hydraulic operator and the electronic 

control unit.  
The operator, which moves the beam, consists of a hydraulic 

power pack and a double-acting cylinder. 
The system is supplied with an adjustable torque limitation 

system. It also includes a device stopping the beam in any 

position, and a handy manual release command for use in 

case of power cuts or faults.
The beam and the relevant balancing spring must be ordered 

by referring to the sales price list.

The 615BPR automated system was designed and built 

for controlling vehicle access. 

Do not use for any other 

purpose.

The curve makes it possible to establish maximum work time (T) 

according to use frequency (F).

E.g. The 615 BPR automated system can operate non-stop at a use 

frequency of 50%.

To ensure efficient operation, operate in the work range under the 

curve.

Important:

 The curve is obtained at a temperature of 20 

°

C. Exposure 

to the direct sun rays can reduce use frequency down to 20%.

Calculation of use frequency

The percentage of effective work time (o closing) compared 

to total time of cycle (o c pause times).

Calculation formula:

where:

Ta 

= opening time

Tc

 = closing time

Tp

 = pause time

Ti 

 = interval time between

 

one complete cycle and

 another.

 foundation plate

 barrier upright

 control board

 emergency release 

  torque adjustment screws

  double acting piston

  travel limit screw

 

  M12 nut blocking the tie 

rod

 rocker

  oil filling plug 

 breather screw

 balancing spring

  spring adjustment tie-rod

  hydraulic power pack

  travel limit sensors

  travel limit magnets

fig.1

 

Ta + Tc

%F =  X 

100

 

Ta + Tc + Tp + Ti

1.1 MAXIMUM USE CURVE

1 DESCRIPTION AND TECHNICAL SPECIFICATIONS

Tab. 1 - Technical specifications “Barrier 615BPR"

BARRIER MODEL

615BPR STD

615BPR RAP

Beam max. length (m)

5

2,5

Max. opening time (sec)

5,7

2,9

Angular speed (rad/sec)

0.28

0,54

Pump flow-rate (l/min)

1.5

3

Max. torque (Nm)

400

300

Types of beam

Rectangular / Rectangular 

skirt articulated / Round

Use frequency (at 20°C)

50%

40%

Max. consecutive cycles (at 20°C)  

220

340

Power supply

230V~ (+6 -10 %) 50Hz

Absorbed power (W)

220

Type of oil

FAAC HP OIL

Oil quantity (Kg)

0,9

Thermal protection for winding

120° C

Torque adjustment system

standard by-pass valves

Operating ambient temperature

-40 ÷ +55 °C

Hood protective treatment

cataphoresis

Hood paint

Polyester RAL 2004

Protection class

IP 44

Weight (Kg)

34

Upright dimensions LxHxP(mm)

270 x 1015 x 140

Electric motor technical specifications

RPM

1400

2800

Power (W)

220

Absorbed current (A)

1

Power supply

230V~  (+6 -10 %) 50Hz

AUTOMATED SYSTEM 615BPR

Содержание 615

Страница 1: ...615 615...

Страница 2: ...ur les remarques concernant les caract ristiques ou le fonctionnement du produit Vor der Installation des Produkts sind die Anweisungen vollst ndig zu lesen Mit dem Symbol sind wichtige Anmerkungen f...

Страница 3: ...4 INSTALLING THE AUTOMATED SYSTEM 4 4 1 PRELIMINARY CHECKS 4 4 2 MASONRY FOR FOUNDATION PLATE 4 4 3 INSTALLING THE UPRIGHT 4 4 4 INSTALLING THE BEAM 4 4 5 INSTALLING AND ADJUSTING THE BALANCING SPRIN...

Страница 4: ...osing elements to be motorised or for any defor mation that may occur during use 10 The installation must conform to Standards EN 12453 and EN 12445 For non EU countries to obtain an adequate level of...

Страница 5: ...cycle opening closing pause times Calculation formula where Ta opening time Tc closing time Tp pause time Ti interval time between onecompletecycleand another foundation plate barrier upright control...

Страница 6: ...3 INSTALLING THE UPRIGHT 4 4 INSTALLING THE BEAM The 615BPR automated system is always supplied intheright handversion forleft handinstallation see chapter 5 5 1 Makesurethattherodofthepistonsecuredt...

Страница 7: ...5 ENGLISH fig 7b fig 5 fig 7a IMPORTANT moderatelytightenthe pocket securing screw max 30Nm fig 6 fig 8 IMPORTANT moderatelytightenthepocketsecuring screw max 30Nm...

Страница 8: ...g for the beam which must be ordered separately The spring varies according to length and type of beam rigid skirt or articulated Consult the tables below to see if the spring matches 5 BALANCING SPRI...

Страница 9: ...11 ref 1 Fit the standard triangular key Fig 13 in the lock and turn it anti clockwise through 1 turn Open and close the barrier manually To prevent an involuntary impulse from activating the barrier...

Страница 10: ...pring must be adapted FORK SUPPORT fig 15 The fork has two functions itpreventsthebeam whenclosed frombendingorsplitting if its end is stressed by extraneous forces it allows the beam to rest when clo...

Страница 11: ...in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der v...

Отзывы: