Solar Power
You can use solar power if required. You will require a DC voltage regulator applied at
the gate board end as the voltage output can vary and cause too high a voltage, which
will damage the intercom if over the 26v DC.
Our systems would require as a minimum a 30W of solar panel capacity and 10ah
battery capacity for our intercoms.
Notes:
This
unit’s draw is 96mA
standby, 500mA calling with
up to 2A spikes.
Note:
Please adhere to the cable thickness guide or
the device may be damaged and rendered out of
warranty by the manufacturer.
Up to 2 meters (6 feet) use minimum 0.5mm / 18 gauge cable.
Up to 4 meters (12 feet) use minimum 1mm / 16 gauge cable.
Up to 8 meters (25 feet) use minimum 1.5mm / 14 gauge cable
Power
Consumption:
Standby = 96mA
Calling Out = 500mA