manualshive.com logo in svg
background image

Page 5 

November, 2003 
422 User Manual 

M

ANUAL

 R

ELEASE

 M

ECHANISM

 

 

The manuals release mechanism is located on the top of 
your 422 operator (see figure 2) To access the keyhole, 
slide the keyhole cover in the direction of the arrow (see 
figure 1). Insert the key and turn it counterclockwise 
one full turn to disengage the operator's hydraulic 
system. You can now move the gate leaf slowly by hand 
to open or close the gate. 
 

N

OTE

: Operating the gate leaf by hand is necessary 

during power failures. 

 
You re-engage the hydraulic system by turning the key 
clockwise one full turn (or until snug). Remove the key 
and slide the cover closed. 
 

C

AUTION

:  Over tightening the manual release 

mechanism can damage or even break the key. 

Figure 1.  

After sliding the cover open on 

the Model 422,  insert and turn 

the key counterclockwise one  

full turn to release the hydraulic 

system  

T

HE

 422 O

PERATOR

 

 

The FAAC recommended maintenance schedule varies 

according to the frequency of use of the operators, 

whether lightly used operators (once or twice an hour) 

or heavily used operators (many cycles per hour). 

Operators used in a humid/ salt air climate should 

follow the heavy duty use schedule. 

 
 

Check the oil.

 

 

To check the oil level correctly, remove the locking cap 

from the operator. The operator should be at least half 

full. 

 
  

Note: 

You will not be able to see the oil level. 

Use something flexible (i.e. A piece of stranded 

wire) to act as a dipstick. 

 

 If the operator is too full, it will bleed oil out the vent 

hole. 

 

  

Light duty use: check once per year 

 

Heavy duty use: check every 6 mo 

Change the oil. 

 

Changing the oil requires removing the operator from 

its installed position. Remove the locking cap and drain 

the oil out of the hole under the cap. Refill the operator 

with the proper new oil (see page 4). 

 

  

Light duty use: change every 4 yr 

 

Heavy duty use: change every 2 yr 

 
 

Check the pressure settings.

 

 

  

Light duty use: check once per year 

 

Heavy duty use: check every 6 mo 

 

 

T

HE

 G

ATE

 S

YSTEM

 

 

A qualified technician should check the entire gate 

system periodically for proper operation.  All reversing 

devices should be functioning properly, as well as the 

422 operators. 

M

AINTENANCE

 

Figure 2.  

Insert the manual release 

key in the locking cap 

located on the top of the 

422 Operator. 

Отзывы: