455 D  Control Panel I nst allatio n M anual   

6.  It is extremely unsafe to compensate for a damaged 

gate by increasing hydraulic pressure. 

7.  Devices such as reversing edges and photobeams 

must be installed to provide better protection for 
personal property and pedestrians. Install reversing 
devices that are appropriate to the gate design and 

gate application. 

8.  Before applying electrical power, be sure that the 

voltage requirements of the equipment correspond 

to your supply voltage. Refer to the label on your 
operator system. 

 

U

SE

 

 

1.  Use this equipment only in the capacity for which it 

was designed. Any use other than that stated should 
be considered improper and therefore dangerous. 

2.  When using any electrical equipment, observe some 

fundamental rules:  

• 

Do not touch the equipment with damp or 
humid hands or feet. 

• 

Do not install or operate the equipment 
with bare feet. 

• 

Do not allow small children or incapable 
persons to use the equipment. 

3.  If a gate system component malfunctions, turn off 

the main power before making any attempt to repair 
it. 

4.  Do not attempt to impede the movement of the 

gate. You may injure yourself as a result. 

5. This equipment may reach high temperatures 

during operation; therefore, use caution when 
touching the external housing of the operator. 

6. Learn to use the manual release mechanism 

according to the procedures found in this in-
stallation manual. 

7.  Before carrying out any cleaning or maintenance 

operations, disconnect the equipment from the 
electrical supply.  

8.  To guarantee the efficiency of this equipment, the 

manufacturer recommends that qualified personnel 
periodically check and maintain the equipment. 

Model 

Duty Cycle 

Typical Use 

Class I: Residential Vehicular Gate Operator 

 402 

750 

 422 

760 

 412 

400 

 620          640 
 885 

Limited duty 

• 

Home use 

• 

Small apartment building, for 
example, up to 4 units in a 

building, with limited public 
access 

Class II: Commercial/General Access Vehicular Gate Operator 

 400 

640 

 620 

885 

Continuous duty 

• 

Apartment buildings 

• 

Very public access 

Class III: Industrial/Limited Access Vehicular Gate Operator 

 400 

640 

 620          885 

Continuous duty 

• 

No public access 

Class IV: Restricted Access Vehicular Gate Operator 

 620 

640 

885 

Continuous duty 

• 

Prison rated security 

U.L. C

LASS

 

AND

 FAAC O

PERATOR

 

Содержание 412 Compact

Страница 1: ...l the Operator 7 Install the 455 D Control Panel 10 Exploded View 412 12 412 Parts List 13 The 455 D Control Panel General Description 14 Installing the 455 D Control Panel 14 Connect the Main Power S...

Страница 2: ...affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose to install on your gate must be designed for the type and size of your gate and for the...

Страница 3: ...power before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a result 5 This equipment may reach high temperatures during operation ther...

Страница 4: ...aximum leaf swing deg 110 Thrust and traction3 ft lb Nm 0 294 0 400 0 235 0 320 Stroke in cm 11 3 8 29 Rod speed 4 in sec cm sec 3 4 1 9 5 8 1 6 Thermal cut out deg F deg C 284 140 Operator dimensions...

Страница 5: ...s marked DX Be sure to install each on the proper gate leaf see Figure 2 2 Protective covers for the worm screw housing of the operator 1 Package of mounting hardware 2 Rear mounting brackets 2 Rear m...

Страница 6: ...anism that precisely controls the force transmitted to the gate leaf through the 412 Operator The Manual Release mechanism is a key operated device that disengages or engages the worm screw drive of t...

Страница 7: ...e where the operators are mounted The operator attached to the hinge on the left of the gate must be an SX model If the hinge is on the right side the DX model must be installed Installing the operato...

Страница 8: ...front mounting bracket with the short pin and one snap ring on the bottom and one snap ring on the top see Figure 9 11 13 16 in 30 cm 4 in 10 cm 5 29 32 in 15 cm Figure 6 The required dimensions of th...

Страница 9: ...Gate post or column Steel elbow A B C D F Centerline of gate leaf E Mounting Dimensions 90 deg Swing 110 deg Swing A 5 3 4 in 14 5 cm 4 7 8 in 12 5 cm B 5 3 4 in 14 5 cm 4 7 8 in 12 5 cm WARNING A an...

Страница 10: ...OPERATOR COVER Once the operator is attached to the gate leaf you next prepare the cover for installation Caution If you did not correctly establish the orientation of the gate leaf and properly inst...

Страница 11: ...d 455 D Control Panel Installation Manual 1 Operator Wire Gauges for Given Voltage 2 Control Panel 220 VAC 115 VAC 3 Photocell A 2 18 AWG A 2 18 AWG 4 Switch B 4 14 AWG B 4 14 AWG 5 Junction box see t...

Страница 12: ...Page 12 January 2004 412 Operator And 455 D Control Panel Installation Manual The 412 Compact Operator...

Страница 13: ...p Protective Cover SX 1 8 727147 End Cap Protective Cover DX 1 9 N A Nickel Plated Self Tapping Screw 3 5 x 9 5 mm 3 10 2705 Capacitor For 115 v 25 f 1 10 2707 Capacitor For 220 v 8 f 1 11 727216 Prot...

Страница 14: ...that the entire gate system meets all applicable electrical codes The installer should refer to the installation manual for a given operator for more information NOTE An installation is U L compliant...

Страница 15: ...e to 2 and the red wire to 3 Wire each leg of the capacitor supplied to terminals 2 3 Note If you want to delay the closing of one gate leaf in a two leaf gate design be sure to connect its operator t...

Страница 16: ...in power and send an activating signal to the operator The gate leaf or leaves should open If a gate leaf closes then you need to turn off the main power and reverse the connection of the red and blac...

Страница 17: ...e motors without a closed circuit between 11 14 The LED Indicators The nine light emitting diodes LEDs on the control panel can be used to check for the proper function of the devices attached to the...

Страница 18: ...he delayed leaf closes at the end of the closing time opening and closing respectively are triggered Use the LEDs and the next table to determine if the accessory devices you have installed are operat...

Страница 19: ...ev ices 14 9 C NO Rev ersing Photocells f or opening 1 2 1 2 3 4 5 17 13 19 14 17 Additional Reversing Devices TX RX 1 2 1 2 3 4 5 19 17 12 19 17 Additional Reversing Devices TX RX 1 2 19 12 17 15 Add...

Страница 20: ...he value that can be modified with keys and When you reach the last function press the F key to exit the program and the display resumes showing the status of the inputs The table on page 21 shows the...

Страница 21: ...ou sands from 0 to 99 thousand cy cles The displayed value is up dated as cycles proceed This func tion can be used to check use of the board or to exploit the Assistance Request function EXTRA WORK T...

Страница 22: ...ay stops flashing LEARNING OF OPERATING TIMES WARNING During the learning procedure the safety devices are disabled Therefore any and all traffic must be avoided in the path of the gate leaf s NOTE Pr...

Страница 23: ...and must be given to start the slow down phase When the gate operator reaches its positive stop the operator will automatically shut off An open command must be given to start closing gate operator 2...

Страница 24: ...g Reversing Device s Warning Light Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Ope...

Страница 25: ...s in hibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer trig gered No effect On Opened Closes both le...

Страница 26: ...directions before the automatic operator is installed An automatic operator should be installed on the inside of the property fence line Do not install the operator on the public side of the property...

Страница 27: ...OPENS BUT DOES NOT CLOSE SOLUTION Make sure you have selected the desired operating mode Verify that the reversing devices are working properly FSWOP and FSWCL should be illuminated except when a rev...

Страница 28: ...rdance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s...